Ultra scale‐down approach to correct dispersive and retentive effects in small‐scale columns when predicting larger scale elution profiles

Ultra scale‐down approaches represent valuable methods for chromatography development work in the biopharmaceutical sector, but for them to be of value, scale‐down mimics must predict large‐scale process performance accurately. For example, one application of a scale‐down model involves using it to predict large‐scale elution profiles correctly with respect to the size of a product peak and its position in a chromatogram relative to contaminants. Predicting large‐scale profiles from data generated by small laboratory columns is complicated, however, by differences in dispersion and retention volumes between the two scales of operation. Correcting for these effects would improve the accuracy of the scale‐down models when predicting outputs such as eluate volumes at larger scale and thus enable the efficient design and operation of subsequent steps. This paper describes a novel ultra scale‐down approach which uses empirical correlations derived from conductivity changes during operation of laboratory and pilot columns to correct chromatographic profiles for the differences in dispersion and retention. The methodology was tested by using 1 mL column data to predict elution profiles of a chimeric monoclonal antibody obtained from Protein A chromatography columns at 3 mL laboratory‐ and 18.3 L pilot‐scale. The predictions were then verified experimentally. Results showed that the empirical corrections enabled accurate estimations of the characteristics of larger‐scale elution profiles. These data then provide the justification to adjust small‐scale conditions to achieve an eluate volume and product concentration which is consistent with that obtained at large‐scale and which can then be used for subsequent ultra scale‐down operations. © 2009 American Institute of Chemical Engineers Biotechnol. Prog., 2009

[1]  S Karri,et al.  A Tool for Modeling Strategic Decisions in Cell Culture Manufacturing , 2000, Biotechnology progress.

[2]  M. Teeters,et al.  Evaluating and monitoring the packing behavior of process-scale chromatography columns. , 2005, Journal of chromatography. A.

[3]  H. Verelst,et al.  Computational study of the band broadening in two-dimensional etched packed bed columns for on-chip high-performance liquid chromatography. , 2004, Journal of chromatography. A.

[4]  M. Polakovič,et al.  Extra-column dispersion of macromolecular solutes in aqueous-phase size-exclusion chromatography. , 2004, Journal of chromatography. A.

[5]  A. Rizzi,et al.  Influence of the accuracy of the extra-column peak-width determination on the verificaton of theoretical plate-height equations , 1987 .

[6]  A. Rathore,et al.  Guidelines for optimization and scale-up in preparative chromatography , 2003 .

[7]  Alois Jungbauer,et al.  Prediction of the preparative chromatography performance with a very small column , 1997 .

[8]  J. Bonnerjea,et al.  Scale-up of monoclonal antibody purification processes. , 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[9]  G. Guiochon,et al.  Influence of the errors made in the measurement of the extra-column volume on the accuracies of estimates of the column efficiency and the mass transfer kinetics parameters. , 2006, Journal of chromatography. A.

[10]  Jeff Davis,et al.  Use of Process Data To Assess Chromatographic Performance in Production‐Scale Protein Purification Columns , 2003, Biotechnology progress.

[11]  Xuejun Han,et al.  Protein aggregation kinetics during Protein A chromatography. Case study for an Fc fusion protein. , 2007, Journal of chromatography. A.

[12]  Yuhong Zhou,et al.  Application of a Decision‐Support Tool to Assess Pooling Strategies in Perfusion Culture Processes under Uncertainty , 2008, Biotechnology progress.

[13]  N Hutchinson,et al.  Shear stress analysis of mammalian cell suspensions for prediction of industrial centrifugation and its verification , 2006, Biotechnology and bioengineering.

[14]  L. Kirkup,et al.  Comparison of equations describing band broadening in high-performance liquid chromatography. , 2004, Journal of chromatography. A.

[15]  P. Dephillips,et al.  Pore size distributions of cation-exchange adsorbents determined by inverse size-exclusion chromatography. , 2000, Journal of chromatography. A.

[16]  T. Ikegami,et al.  Faster axial band dispersion in a monolithic silica column than in a particle-packed column. , 2006, Journal of chromatography. A.

[17]  P Dunnill,et al.  Micro biochemical engineering to accelerate the design of industrial‐scale downstream processes for biopharmaceutical proteins , 2008, Biotechnology and bioengineering.