An adaptive optics imaging system designed for clinical use.

Here we demonstrate a new imaging system that addresses several major problems limiting the clinical utility of conventional adaptive optics scanning light ophthalmoscopy (AOSLO), including its small field of view (FOV), reliance on patient fixation for targeting imaging, and substantial post-processing time. We previously showed an efficient image based eye tracking method for real-time optical stabilization and image registration in AOSLO. However, in patients with poor fixation, eye motion causes the FOV to drift substantially, causing this approach to fail. We solve that problem here by tracking eye motion at multiple spatial scales simultaneously by optically and electronically integrating a wide FOV SLO (WFSLO) with an AOSLO. This multi-scale approach, implemented with fast tip/tilt mirrors, has a large stabilization range of ± 5.6°. Our method consists of three stages implemented in parallel: 1) coarse optical stabilization driven by a WFSLO image, 2) fine optical stabilization driven by an AOSLO image, and 3) sub-pixel digital registration of the AOSLO image. We evaluated system performance in normal eyes and diseased eyes with poor fixation. Residual image motion with incremental compensation after each stage was: 1) ~2-3 arc minutes, (arcmin) 2) ~0.5-0.8 arcmin and, 3) ~0.05-0.07 arcmin, for normal eyes. Performance in eyes with poor fixation was: 1) ~3-5 arcmin, 2) ~0.7-1.1 arcmin and 3) ~0.07-0.14 arcmin. We demonstrate that this system is capable of reducing image motion by a factor of ~400, on average. This new optical design provides additional benefits for clinical imaging, including a steering subsystem for AOSLO that can be guided by the WFSLO to target specific regions of interest such as retinal pathology and real-time averaging of registered images to eliminate image post-processing.

[1]  David Williams,et al.  Functional photoreceptor loss revealed with adaptive optics: an alternate cause of color blindness. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[2]  William S Tuten,et al.  Adaptive optics microperimetry and OCT images show preserved function and recovery of cone visibility in macular telangiectasia type 2 retinal lesions. , 2015, Investigative ophthalmology & visual science.

[3]  Daniel X Hammer,et al.  Large-field-of-view, modular, stabilized, adaptive-optics-based scanning laser ophthalmoscope. , 2007, Journal of the Optical Society of America. A, Optics, image science, and vision.

[4]  C. Curcio,et al.  Photoreceptor perturbation around subretinal drusenoid deposits as revealed by adaptive optics scanning laser ophthalmoscopy. , 2014, American journal of ophthalmology.

[5]  Christopher S. Langlo,et al.  In vivo imaging of human cone photoreceptor inner segments. , 2014, Investigative ophthalmology & visual science.

[6]  R. D. Ferguson,et al.  Adaptive optics scanning laser ophthalmoscope for stabilized retinal imaging. , 2006, Optics express.

[7]  T. Hebert,et al.  Adaptive optics scanning laser ophthalmoscopy. , 2002, Optics express.

[8]  David R Williams,et al.  In vivo imaging of retinal pigment epithelium cells in age related macular degeneration. , 2013, Biomedical optics express.

[9]  David Williams,et al.  Noninvasive imaging of the human rod photoreceptor mosaic using a confocal adaptive optics scanning ophthalmoscope , 2011, Biomedical optics express.

[10]  Daniel X Hammer,et al.  Adaptive optics scanning laser ophthalmoscope with integrated wide-field retinal imaging and tracking. , 2010, Journal of the Optical Society of America. A, Optics, image science, and vision.

[11]  Jennifer J. Hunter,et al.  Imaging retinal mosaics in the living eye , 2011, Eye.

[12]  A. Dubra,et al.  Reflective afocal broadband adaptive optics scanning ophthalmoscope , 2011, Biomedical optics express.

[13]  Austin Roorda,et al.  Correcting for miniature eye movements in high resolution scanning laser ophthalmoscopy , 2005 .

[14]  Kenichi Saito,et al.  Closed-loop optical stabilization and digital image registration in adaptive optics scanning light ophthalmoscopy. , 2014, Biomedical optics express.

[15]  David Williams Imaging single cells in the living retina , 2011, Vision Research.

[16]  Katherine E. Talcott,et al.  Longitudinal study of cone photoreceptors during retinal degeneration and in response to ciliary neurotrophic factor treatment. , 2011, Investigative ophthalmology & visual science.

[17]  Donald T. Miller,et al.  In vivo functional imaging of human cone photoreceptors. , 2007, Optics express.

[18]  Toco Y P Chui,et al.  Classification of human retinal microaneurysms using adaptive optics scanning light ophthalmoscope fluorescein angiography. , 2014, Investigative ophthalmology & visual science.

[19]  Robert J Zawadzki,et al.  Ultrahigh-resolution optical coherence tomography with monochromatic and chromatic aberration correction. , 2008, Optics express.

[20]  David H Sliney,et al.  Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices. , 2007, Journal of the Optical Society of America. A, Optics, image science, and vision.

[21]  Judy E. Kim,et al.  Microscopic inner retinal hyper-reflective phenotypes in retinal and neurologic disease. , 2014, Investigative ophthalmology & visual science.