Accuracy and reproducibility of co-registration techniques based on mutual information and normalized mutual information for MRI and SPECT brain images

We implemented a 3D co-registration technique based on mutual information (MI) including 2D image matching as a coarse pre-registration. The 2D coarse pre-registration was performed in the transverse, sagittal and coronal planes sequentially, and all six parameters were then optimized as fine registration. Normalized mutual information (NMI) was also examined as another entropybased measure that was invariant to the overlapped area of two images. In order to compare accuracy and precision of the present method with a conventional two-level multiresolution approach, simulation was performed by 100 trials with the random initial mismatch of ±10° and ±17.92 mm (Type-I) and ±20° and ±40.32 mm (Type-II). For Type-I, no significant differences were found between registration errors of the multiresolution approach and the present method with the MI criterion. No biases were observed (≤0.13° and ≤0.57 mm for the multiresolution approach; ≤0.12° and ≤0.57 mm for the present method) and the SDs were very small (≤0.18° and ≤0.12 mm for the multiresolution approach; ≤0.11° and ≤0.11 mm for the present method). For Type-II, SDs for the multiresolution approach (≤1.8° and ≤0.88 mm) were markedly larger than those for the present method (≤0.64° and ≤0.20 mm) with MI. Success rate for the present method was 99.9%, which was higher than 97.6% for the multiresolution approach. Simulation also revealed that MI and NMI performance were almost equivalent. The choice of optimization strategy more affected accuracy and reproducibility than the choice of the registration criterion (MI or NMI) in our simulation condition. The present method is sufficiently accurate and reproducible for MRI-SPECT registration in clinical use.

[1]  Paul Suetens,et al.  Comparative evaluation of multiresolution optimization strategies for multimodality image registration by maximization of mutual information , 1999, Medical Image Anal..

[2]  David J. Hawkes,et al.  Voxel similarity measures for 3-D serial MR brain image registration , 1999, IEEE Transactions on Medical Imaging.

[3]  M E Phelps,et al.  Automated image registration for FDOPA PET studies. , 1996, Physics in medicine and biology.

[4]  Colin Studholme,et al.  Evaluation of the limits of visual detection of image misregistration in a brain fluorine-18 fluorodeoxyglucose PET MRI study , 1997, European Journal of Nuclear Medicine.

[5]  S. Strother,et al.  Quantitative Comparisons of Image Registration Techniques Based on High‐Resolution MRI of the Brain , 1994, Journal of computer assisted tomography.

[6]  C. Crone,et al.  THE PERMEABILITY OF CAPILLARIES IN VARIOUS ORGANS AS DETERMINED BY USE OF THE 'INDICATOR DIFFUSION' METHOD. , 1963, Acta physiologica Scandinavica.

[7]  Kazuyoshi Suga,et al.  Technical and analytical advances in pulmonary ventilation SPECT with xenon-133 gas and Tc-99m-Technegas , 2002, Annals of nuclear medicine.

[8]  Yang-Ming Zhu,et al.  Influence of implementation parameters on registration of MR and SPECT brain images by maximization of mutual information. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  Jeffrey Tsao,et al.  Interpolation artifacts in multimodality image registration based on maximization of mutual information , 2003, IEEE Transactions on Medical Imaging.

[10]  K. Murase,et al.  Attenuation correction of myocardial SPECT images with X-ray CT: Effects of registration errors between X-ray CT and SPECT , 2002, Annals of nuclear medicine.

[11]  Peter Bartenstein,et al.  SPET/CT image co-registration in the abdomen with a simple and cost-effective tool , 2002, European Journal of Nuclear Medicine and Molecular Imaging.

[12]  Guy Marchal,et al.  Automated multi-modality image registration based on information theory , 1995 .

[13]  M. Zanca,et al.  A comparative study of Powell's and Downhill Simplex algorithms for a fast multimodal surface matching in brain imaging. , 2001, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[14]  Michael Unser,et al.  A pyramid approach to sub-pixel image fusion based on mutual information , 1996, Proceedings of 3rd IEEE International Conference on Image Processing.

[15]  H. Zaidi,et al.  Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography. , 2003, Medical physics.

[16]  V. Poutanen,et al.  Abdominal SPECT/MRI fusion applied to the study of splenic and hepatic uptake of radiolabeled thrombocytes and colloids , 1996, Annals of nuclear medicine.

[17]  D L Hill,et al.  Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures. , 1997, Medical physics.

[18]  Y Yonekura,et al.  Nonlinearity correction of brain perfusion SPECT based on permeability-surface area product model. , 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  R. Wahl,et al.  "Anatometabolic" tumor imaging: fusion of FDG PET with CT or MRI to localize foci of increased activity. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[20]  B. Ardekani,et al.  A Fully Automatic Multimodality Image Registration Algorithm , 1995, Journal of computer assisted tomography.

[21]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[22]  Guy Marchal,et al.  Multi-modality image registration by maximization of mutual information , 1996, Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis.

[23]  Guy Marchal,et al.  Automated multi-moda lity image registration based on information theory , 1995 .

[24]  Karl J. Friston,et al.  Statistical parametric maps in functional imaging: A general linear approach , 1994 .

[25]  Guy Marchal,et al.  Multimodality image registration by maximization of mutual information , 1997, IEEE Transactions on Medical Imaging.

[26]  B. F. Hutton,et al.  Improved efficiency for MRI-SPET registration based on mutual information , 2000, European Journal of Nuclear Medicine.

[27]  Paul A. Viola,et al.  Alignment by Maximization of Mutual Information , 1997, International Journal of Computer Vision.

[28]  Lennart Thurfjell,et al.  Validation of fully automatic brain SPET to MR co-registration , 2000, European Journal of Nuclear Medicine.

[29]  Max A. Viergever,et al.  Quantitative evaluation of convolution-based methods for medical image interpolation , 2001, Medical Image Anal..

[30]  J. Mazziotta,et al.  MRI‐PET Registration with Automated Algorithm , 1993, Journal of computer assisted tomography.

[31]  Sang Joon Kim,et al.  A Mathematical Theory of Communication , 2006 .

[32]  Max A. Viergever,et al.  Image registration by maximization of combined mutual information and gradient information , 2000, IEEE Transactions on Medical Imaging.

[33]  Colin Studholme,et al.  An overlap invariant entropy measure of 3D medical image alignment , 1999, Pattern Recognit..

[34]  Irène Buvat,et al.  A Methodology to Validate MRI/SPECT Registration Methods Using Realistic Simulated SPECT Data , 2001, MICCAI.

[35]  E. M. Renkin Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscles. , 1959, The American journal of physiology.

[36]  John A. Nelder,et al.  A Simplex Method for Function Minimization , 1965, Comput. J..

[37]  Gerald Q. Maguire,et al.  Comparison and evaluation of retrospective intermodality brain image registration techniques. , 1997, Journal of computer assisted tomography.

[38]  R. Wahl,et al.  Comparison of mutual information-based warping accuracy for fusing body CT and PET by 2 methods: CT mapped onto PET emission scan versus CT mapped onto PET transmission scan. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[39]  Jonathan S. Lewin,et al.  Semiautomatic 3-D image registration as applied to interventional MRI liver cancer treatment , 2000, IEEE Transactions on Medical Imaging.

[40]  D. Rueckert,et al.  Comparison and evaluation of rigid, affine, and nonrigid registration of breast MR images. , 1999, Journal of computer assisted tomography.

[41]  G. Marchal,et al.  Multi-modal volume registration by maximization of mutual information , 1997 .

[42]  P J Slomka,et al.  Evaluation of linear registration algorithms for brain SPECT and the errors due to hypoperfusion lesions. , 2001, Medical physics.