Local elasticity imaging of vascular tissues using a tactile mapping system

This study aimed to map the elasticity of a natural artery at the micron level by using a tactile mapping system (TMS) that was recently developed for characterization of the stiffness of tissue slices. The sample used was a circumferential section (thickness, approximately 1 mm) of a small-caliber porcine artery (diameter, approximately 3 mm). Elasticity was measured with a probe of diameter 1 μm and a spatial resolution of 2 μm at a rate of 0.3 s per point, without significant sample invasion. Topographical measurements were also performed simultaneously. Wavy regions of high elasticity, layered in the circumferential direction, were measured at the tunica media, which was identified as an elastin-rich region. The Young’s modulus of the elastin-rich region in the media was 50.8 ± 13.8 kPa, and that of the elastin-rich region of the lamina elastica interna was 69.0 ± 12.8 kPa. Both these values were higher than the Young’s modulus of the other regions in the media, including smooth muscle cells and collagen fibrils (17.0 ± 9.0 kPa). TMS is simple and inexpensive to perform and allows observation of the distribution of the surface elastic modulus at the extracellular matrix level in vascular tissue. TMS is expected to be a powerful tool in evaluation of the maturation and degree of reconstruction in the development of tissue-engineered or artificial tissues and organs.

[1]  Ueli Aebi,et al.  Dynamic elastic modulus of porcine articular cartilage determined at two different levels of tissue organization by indentation-type atomic force microscopy. , 2004, Biophysical journal.

[2]  S. Omata,et al.  Micro-mechanical sensing platform for the characterization of the elastic properties of the ovum via uniaxial measurement. , 2004, Journal of biomechanics.

[3]  Y. Nakayama,et al.  Development of the wing-attached rod for acceleration of "Biotube" vascular grafts fabrication in vivo. , 2007, Journal of biomedical materials research. Part B, Applied biomaterials.

[4]  Joyce Y Wong,et al.  A simple microindentation technique for mapping the microscale compliance of soft hydrated materials and tissues. , 2006, Journal of biomedical materials research. Part A.

[5]  Y. Nakayama,et al.  "In Vivo Tissue-Engineered" Valved Conduit With Designed Molds and Laser Processed Scaffold , 2008, The Journal of cardiovascular nursing.

[6]  J. Gosline,et al.  Elastic proteins: biological roles and mechanical properties. , 2002, Philosophical transactions of the Royal Society of London. Series B, Biological sciences.

[7]  J D Humphrey,et al.  Mechanics of the arterial wall: review and directions. , 1995, Critical reviews in biomedical engineering.

[8]  Y. Nakayama,et al.  Development of biotube vascular grafts incorporating cuffs for easy implantation , 2007, Journal of Artificial Organs.

[9]  Nadine Aubry,et al.  Aging increases stiffness of cardiac myocytes measured by atomic force microscopy nanoindentation. , 2003, American journal of physiology. Heart and circulatory physiology.

[10]  S Omata,et al.  Objective evaluation of liver consistency to estimate hepatic fibrosis and functional reserve for hepatectomy. , 2000, Journal of the American College of Surgeons.

[11]  J. Ando,et al.  Development of an in vivo tissue-engineered, autologous heart valve (the biovalve): preparation of a prototype model. , 2007, The Journal of thoracic and cardiovascular surgery.

[12]  J. R. Hewit,et al.  Tactile sensing technology for minimal access surgery––a review , 2003 .

[13]  S. Omata,et al.  Development of Tactile Mapping system for the stiffness characterization of tissue slice using novel tactile sensing technology , 2005 .

[14]  Gerber,et al.  Atomic Force Microscope , 2020, Definitions.

[15]  Sadao Omata,et al.  New tactile sensor like the human hand and its applications , 1992 .

[16]  H. Miyazaki,et al.  A newly designed tensile tester for cells and its application to fibroblasts. , 2000, Journal of biomechanics.

[17]  Y. Nakayama,et al.  Architecture of an in vivo-tissue engineered autologous conduit "Biovalve". , 2008, Journal of biomedical materials research. Part B, Applied biomaterials.

[18]  Sadao Omata,et al.  Fabrication of micro tactile sensor for the measurement of micro-scale local elasticity , 2004 .

[19]  F. Manns,et al.  Atomic force microscopy measurements of lens elasticity in monkey eyes , 2007, Molecular vision.