Localisation of partial discharge sources using radio fingerprinting technique

Partial discharge (PD) is a well-known indicator of the failure of insulators in electrical plant. Operators are pushing toward lower operating cost and higher reliability and this stimulates a demand for a diagnostic system capable of accurately locating PD sources especially in ageing electricity substations. Existing techniques used for PD source localisation can be prohibitively expensive. In this paper, a cost-effective radio fingerprinting technique is proposed. This technique uses the Received Signal Strength (RSS) extracted from PD measurements gathered using RF sensors. The proposed technique models the complex spatial characteristics of the radio environment, and uses this model for accurate PD localisation. Two models were developed and compared: k-nearest neighbour and a feed-forward neural network which uses regression as a form of function approximation. The results demonstrate that the neural network produced superior performance as a result of its robustness against noise.

[1]  B. T. Phung,et al.  Partial discharge localization in transformers using UHF detection method , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[2]  Masatake Kawada,et al.  Localization of a Partial Discharge Source Using Maximum Likelihood Estimation , 2010 .

[3]  Prashant Krishnamurthy,et al.  Modeling of indoor positioning systems based on location fingerprinting , 2004, IEEE INFOCOM 2004.

[4]  P.J. Moore,et al.  Partial discharge investigation of a power transformer using wireless wideband radio-frequency measurements , 2006, IEEE Transactions on Power Delivery.

[5]  Ki-Doo Kim,et al.  RSS-Based Indoor Localization Algorithm for Wireless Sensor Network Using Generalized Regression Neural Network , 2012 .

[6]  Alfred O. Hero,et al.  Relative location estimation in wireless sensor networks , 2003, IEEE Trans. Signal Process..

[7]  L.E. Lundgaard,et al.  Partial discharge. XIV. Acoustic partial discharge detection-practical application , 1992, IEEE Electrical Insulation Magazine.

[8]  P.J. Moore,et al.  RF-Based Partial Discharge Early Warning System for Air-Insulated Substations , 2009, IEEE Transactions on Power Delivery.

[9]  Sofiène Affes,et al.  Neural Networks for Fingerprinting-Based Indoor Localization Using Ultra-Wideband , 2009, J. Commun..

[10]  M. M. Yaacob,et al.  Review on partial discharge detection techniques related to high voltage power equipment using different sensors , 2014 .

[11]  Rongbiao Zhang,et al.  Environmental-adaptive indoor radio path loss model for wireless sensor networks localization , 2011 .

[12]  Philip J. Moore,et al.  Characterisation of radio frequency interference from high voltage electricity supply equipment , 2003 .

[13]  J. Ramirez-Niño,et al.  Analysis of partial electrical discharges in insulating materials through the wavelet transform , 1998 .

[14]  P.J. Moore,et al.  Radiometric location of partial discharge sources on energized high-Voltage plant , 2005, IEEE Transactions on Power Delivery.

[15]  Chahe Nerguizian,et al.  Neural network and fingerprinting-based localization in dynamic channels , 2009, 2009 IEEE International Symposium on Intelligent Signal Processing.