Effect of bite tray impression technique on relocation accuracy in frameless stereotactic radiotherapy.

A previously developed method for achieving patient relocation in fractionated stereotactic radiotherapy (attachment of an infrared fiducial system to a bite tray) relies on the integrity of a bite tray system that incorporates moulding to the patient's upper dentition. Reproducible and accurate patient positioning requires stability of the bite tray and mould during the full treatment process, both during the time the bite tray is inserted in the patient's mouth, and between separate bite tray insertions. The optimum construction method for a stable reproducible tray has not been sufficiently investigated. We undertook a study to identify factors which might influence the integrity of the hard palate bite tray system. Reprosil Fast Set Putty was used to construct 3 impression conditions; teeth only; teeth and alveolar sulcus; and teeth, alveolar sulcus, and the hard palate. Reproducibility was assessed by volunteers inserting the impressions multiple times and recording the locations of 8 standard reference points. Our results showed the optimal impression technique (i.e., the one that led to the smallest ranges in positional and rotational errors) was that which incorporated the teeth, alveolar sulcus, and hard palate.

[1]  A P Warrington,et al.  Relocatable frame for stereotactic external beam radiotherapy. , 1991, International journal of radiation oncology, biology, physics.

[2]  A P Warrington,et al.  Quality assurance in fractionated stereotactic radiotherapy. , 1994, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[3]  Leon S. Lasdon,et al.  Design and Testing of a Generalized Reduced Gradient Code for Nonlinear Programming , 1978, TOMS.

[4]  O A Mendiondo,et al.  A precision repeat localization head frame for fractionated stereotactic radiotherapy. , 1997, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[5]  M Bellerive,et al.  Adaptation and verification of the relocatable Gill-Thomas-Cosman frame in stereotactic radiotherapy. , 1994, International journal of radiation oncology, biology, physics.

[6]  S L Meeks,et al.  Preliminary experience with frameless stereotactic radiotherapy. , 1998, International journal of radiation oncology, biology, physics.

[7]  Patient position reproducibility in fractionated stereotactic radiotherapy: an update after changing dental impression material. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  S L Meeks,et al.  Optic-guided stereotactic radiotherapy. , 1998, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[9]  W Schlegel,et al.  Photogrammetric accuracy measurements of head holder systems used for fractionated radiotherapy. , 1994, International journal of radiation oncology, biology, physics.

[10]  J. Buatti,et al.  The University of Florida frameless high-precision stereotactic radiotherapy system. , 1997, International journal of radiation oncology, biology, physics.

[11]  Michael Brada,et al.  A non-invasive, relocatable stereotactic frame for fractionated radiotherapy and multiple imaging. , 1991 .