Optimal selection of 2D reversed-phase–reversed-phase HPLC separation techniques in bottom-up proteomics

Evaluation of: Stephanowitz H, Lange S, Lang D et al. Improved two-dimensional reversed phase–reversed phase LC-MS/MS approach for identification of peptide–protein interactions. J. Proteome Res. 11(2), 1175–1183 (2011). Recent developments in bottom-up proteomics have supplanted the use of gel-based approaches in favor of multidimensional chromatographic separations of peptide mixtures followed by mass spectrometry analysis. This trend is driven by the desire to eliminate labor-intensive in-gel digestion procedures and increase proteome coverage through better recovery of proteolytic fragments. Introduction of reversed-phase–reversed-phase 2D separation techniques is one of the major improvements that have made this possible. In this article, we review recent developments in 2D HPLC and highlight variations in reversed-phase HPLC separation selectivity that allow for superior peak capacity in peptide fractionation.

[1]  C. Huber,et al.  Separation, detection, and identification of peptides by ion-pair reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry at high and low pH. , 2005, Journal of chromatography. A.

[2]  V. Spicer,et al.  Reversed-Phase HPLC of Peptides – A Valuable Sample Preparation Tool in Bottom-Up Proteomics: Separation Selectivity in Single and Multi-dimensional Separation Modes , 2011 .

[3]  Ying Xu,et al.  Improved peptide elution time prediction for reversed-phase liquid chromatography-MS by incorporating peptide sequence information. , 2006, Analytical chemistry.

[4]  Hongwei Xie,et al.  Utility of retention prediction model for investigation of peptide separation selectivity in reversed-phase liquid chromatography: impact of concentration of trifluoroacetic acid, column temperature, gradient slope and type of stationary phase. , 2010, Analytical chemistry.

[5]  E. Heinzle,et al.  Two-dimensional reversed-phase x ion-pair reversed-phase HPLC: an alternative approach to high-resolution peptide separation for shotgun proteome analysis. , 2007, Journal of proteome research.

[6]  J. Yates,et al.  Multidimensional LC separations in shotgun proteomics. , 2008, Analytical chemistry.

[7]  J. Licinio,et al.  Dynamics of plasma proteome during leptin-replacement therapy in genetically based leptin deficiency , 2011, The Pharmacogenomics Journal.

[8]  O. Krokhin,et al.  Assessment of the reproducibility of random hexapeptide peptide library-based protein normalization. , 2010, Journal of proteome research.

[9]  O. Krokhin,et al.  The effects of infliximab therapy on the serum proteome of rheumatoid arthritis patients , 2009, Arthritis research & therapy.

[10]  Jean-Philippe Lambert,et al.  Proteomics: from gel based to gel free. , 2005, Analytical chemistry.

[11]  Y. Oda,et al.  Evaluation of comprehensive multidimensional separations using reversed-phase, reversed-phase liquid chromatography/mass spectrometry for shotgun proteomics. , 2008, Journal of proteome research.

[12]  W. Ens,et al.  Practical implementation of 2D HPLC scheme with accurate peptide retention prediction in both dimensions for high-throughput bottom-up proteomics. , 2008, Analytical chemistry.

[13]  R. Beavis,et al.  An Improved Model for Prediction of Retention Times of Tryptic Peptides in Ion Pair Reversed-phase HPLC , 2004, Molecular & Cellular Proteomics.

[14]  Sabine S. Lange,et al.  Improved two-dimensional reversed phase-reversed phase LC-MS/MS approach for identification of peptide-protein interactions. , 2012, Journal of proteome research.

[15]  J. Gebler,et al.  Orthogonality of separation in two-dimensional liquid chromatography. , 2005, Analytical chemistry.

[16]  K. Coombs,et al.  Quantitative Proteomic Analyses of Influenza Virus-Infected Cultured Human Lung Cells , 2010, Journal of Virology.

[17]  O. Krokhin,et al.  Sequence-specific retention calculator. Algorithm for peptide retention prediction in ion-pair RP-HPLC: application to 300- and 100-A pore size C18 sorbents. , 2006, Analytical chemistry.

[18]  J. Yates,et al.  Large-scale analysis of the yeast proteome by multidimensional protein identification technology , 2001, Nature Biotechnology.

[19]  Alexander Lazarev,et al.  Sample Preparation in Biological Mass Spectrometry , 2011 .

[20]  Ronald J. Moore,et al.  Reversed‐phase chromatography with multiple fraction concatenation strategy for proteome profiling of human MCF10A cells , 2011, Proteomics.