A nonintrusive temperature measuring system for estimating deep body temperature in bed

Deep body temperature is an important indicator that reflects human being's overall physiological states. Existing deep body temperature monitoring systems are too invasive to apply to awake patients for a long time. Therefore, we proposed a nonintrusive deep body temperature measuring system. To estimate deep body temperature nonintrusively, a dual-heat-flux probe and double-sensor probes were embedded in a neck pillow. When a patient uses the neck pillow to rest, the deep body temperature can be assessed using one of the thermometer probes embedded in the neck pillow. We could estimate deep body temperature in 3 different sleep positions. Also, to reduce the initial response time of dual-heat-flux thermometer which measures body temperature in supine position, we employed the curve-fitting method to one subject. And thereby, we could obtain the deep body temperature in a minute. This result shows the possibility that the system can be used as practical temperature monitoring system with appropriate curve-fitting model. In the next study, we would try to establish a general fitting model that can be applied to all of the subjects. In addition, we are planning to extract meaningful health information such as sleep structure analysis from deep body temperature data which are acquired from this system.

[1]  Fox Rh,et al.  A new technique for monitoring the deep body temperature in man from the intact skin surface. , 1971, The Journal of physiology.

[2]  Xin Zhu,et al.  Development of a new method for the noninvasive measurement of deep body temperature without a heater. , 2010, Medical engineering & physics.

[3]  H. Gunga,et al.  The Double Sensor—A non-invasive device to continuously monitor core temperature in humans on earth and in space , 2009, Respiratory Physiology & Neurobiology.

[4]  Georges Delhomme,et al.  A Non Invasive Wearable Sensor for the Measurement of Brain Temperature , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  D. Tandberg,et al.  Effect of tachypnea on the estimation of body temperature by an oral thermometer. , 1983, The New England journal of medicine.

[6]  T. Terndrup,et al.  Impact of operator technique and device on infrared emission detection tympanic thermometry. , 1992, The Journal of emergency medicine.

[7]  R. Cork,et al.  Precision and Accuracy of Intraoperative Temperature Monitoring , 1983, Anesthesia and analgesia.

[8]  M. Lakhanpaul,et al.  Assessment and initial management of feverish illness in children younger than 5 years: summary of NICE guidance , 2007, BMJ : British Medical Journal.

[9]  R H Fox,et al.  A new technique for monitoring the deep body temperature in man from the intact skin surface. , 1971, The Journal of physiology.

[10]  T. Togawa,et al.  Improved probe for a deep body thermometer , 2006, Medical and Biological Engineering and Computing.

[11]  Zenton Goh,et al.  Evaluation of the Cadi ThermoSENSOR Wireless Skin-Contact Thermometer Against Ear and Axillary Temperatures in Children☆☆☆ , 2010, Journal of Pediatric Nursing.

[12]  R H Fox,et al.  A new method for monitoring deep body temperature from the skin surface. , 1973, Clinical science.

[13]  D. Sessler,et al.  Accuracy and precision of a novel non-invasive core thermometer. , 2009, British journal of anaesthesia.