Effect of balloon size and stepwise inflation technique on the acute results of Inoue mitral commissurotomy. Inoue Balloon Catheter Investigators.

Currently percutaneous transvenous mitral commissurotomy (PTMC) is performed by most operators using stepwise inflation of the Inoue balloon beginning at a small diameter and increasing size by a sequence of inflations to nominal diameter. The effect of balloon size on procedure results using the Inoue balloon has not been evaluated. In 260 patients final balloon inflation was to nominal size in 42% of pts, larger than nominal size (overinflated) in 10%, and less than nominal size (underinflated) in 48% of pts. The average number of inflations was 3 (range 1-9). Pressure gradient and Doppler mitral regurgitation (MR) were assessed after each inflation. When MR increased, further inflations were not done. Patients in whom the balloon was overinflated underwent more balloon inflations than those in whom it was inflated to nominal size (5.0 +/- 2.1 vs. 2.9 +/- 1.4, p < 0.01). Those with balloon underinflation had fewer balloon inflations (2.4 +/- 1.2 vs. 2.9 +/- 1.4, p < 0.01). The post PTMC valve area in patients with overinflation was slightly less than those with nominal inflations (1.6 +/- 0.4 vs. 1.8 +/- 0.7), and with underinflation the valve area was no different compared to nominal inflation. Using a stepwise procedure, if mitral regurgitation was noted to increase after a balloon inflation, the procedure would be stopped even if less than an ideal result was achieved. Fewer inflations were done in patients in whom the balloon was inflated to less than nominal size because of the appearance of mitral regurgitation.(ABSTRACT TRUNCATED AT 250 WORDS)

[1]  J. Carroll,et al.  Factors influencing immediate results, complications, and short-term follow-up status after Inoue balloon mitral valvotomy: a North American multicenter study. , 1992, American heart journal.

[2]  J. Carroll,et al.  Effect of Valve Deformity on Results and Mitral Regurgitation After Inoue Balloon Commissurotomy , 1992, Circulation.

[3]  M. Payet,et al.  The double-balloon and Inoue techniques in percutaneous mitral valvuloplasty: comparative results in a series of 232 cases. , 1991, Journal of the American College of Cardiology.

[4]  K. Inoue Percutaneous transvenous mitral commissurotomy using the Inoue balloon. , 1991, European heart journal.

[5]  J. Carroll,et al.  Valve deformity and balloon mechanics in percutaneous transvenous mitral commissurotomy. , 1991, American heart journal.

[6]  M. Akaike,et al.  Balloon diameter of the Inoue balloon catheter during percutaneous transvenous mitral commissurotomy: clinical and experimental study. , 1991, Catheterization and cardiovascular diagnosis.

[7]  I. Seong,et al.  Percutaneous mitral balloon valvotomy using indue and double balloon technique (randomized trial): Mechanism of dilation, immediate results and follow-up , 1991 .

[8]  P. Manga,et al.  Effect of occlusion of atrial septostomy on calculations of mitral valve area post balloon mitral valvuloplasty , 1991 .

[9]  J. Allen,et al.  Percutaneous double balloon valvotomy for severe rheumatic mitral stenosis. , 1990, The American journal of cardiology.

[10]  A. Vahanian,et al.  Results of percutaneous mitral commissurotomy in 200 patients. , 1989, The American journal of cardiology.

[11]  I. Palacios,et al.  Percutaneous balloon dilatation of the mitral valve: an analysis of echocardiographic variables related to outcome and the mechanism of dilatation. , 1988, British heart journal.

[12]  I. Palacios,et al.  Percutaneous balloon mitral valvotomy for patients with mitral stenosis. Analysis of factors influencing early results. , 1988, The Journal of thoracic and cardiovascular surgery.

[13]  I. Palacios,et al.  Percutaneous balloon valvotomy for patients with severe mitral stenosis. , 1987, Circulation.

[14]  K Inoue,et al.  Clinical application of transvenous mitral commissurotomy by a new balloon catheter. , 1984, The Journal of thoracic and cardiovascular surgery.

[15]  I. Palacios,et al.  Atrial septal occlusion improves the accuracy of mitral valve area determination following percutaneous mitral balloon valvotomy. , 1991, Catheterization and cardiovascular diagnosis.