Characterization of a multi-element clinical HIFU system using acoustic holography and nonlinear modeling

High-intensity focused ultrasound (HIFU) is a treatment modality that relies on the delivery of acoustic energy to remote tissue sites to induce thermal and/or mechanical tissue ablation. To ensure the safety and efficacy of this medical technology, standard approaches are needed for accurately characterizing the acoustic pressures generated by clinical ultrasound sources under operating conditions. Characterization of HIFU fields is complicated by nonlinear wave propagation and the complexity of phased-array transducers. Previous work has described aspects of an approach that combines measurements and modeling, and here we demonstrate this approach for a clinical phased-array transducer. First, low amplitude hydrophone measurements were performed in water over a scan plane between the array and the focus. Second, these measurements were used to holographically reconstruct the surface vibrations of the transducer and to set a boundary condition for a 3-D acoustic propagation model. Finally, nonlinear simulations of the acoustic field were carried out over a range of source power levels. Simulation results were compared with pressure waveforms measured directly by hydrophone at both low and high power levels, demonstrating that details of the acoustic field, including shock formation, are quantitatively predicted.

[1]  E. Tadmor,et al.  New High-Resolution Central Schemes for Nonlinear Conservation Laws and Convection—Diffusion Equations , 2000 .

[2]  P. V. Yuldashev,et al.  Simulation of three-dimensional nonlinear fields of ultrasound therapeutic arrays , 2011, Acoustical physics.

[3]  A. V. Morozov,et al.  Reconstruction of the normal velocity distribution on the surface of an ultrasonic transducer from the acoustic pressure measured on a reference surface , 2003 .

[4]  M Hodnett,et al.  Measurements, phantoms, and standardization , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[5]  M. Myers,et al.  Gaussian representation of high-intensity focused ultrasound beams. , 2007, The Journal of the Acoustical Society of America.

[6]  Lawrence A Crum,et al.  Shock-induced heating and millisecond boiling in gels and tissue due to high intensity focused ultrasound. , 2010, Ultrasound in medicine & biology.

[7]  T. Varslot,et al.  Computer simulation of forward wave propagation in soft tissue , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  L. Crum,et al.  Physical mechanisms of the therapeutic effect of ultrasound (a review) , 2003 .

[9]  Kim C. Benjamin,et al.  Forward and backward projection of acoustic fields using FFT methods , 1981 .

[10]  Zhen Xu,et al.  Effects of acoustic parameters on bubble cloud dynamics in ultrasound tissue erosion (histotripsy). , 2007, The Journal of the Acoustical Society of America.

[11]  Vera A. Khokhlova,et al.  Heating of biological tissues by two-dimensional phased arrays with random and regular element distributions , 2004 .

[12]  Spatial structure of high intensity focused ultrasound beams of various geometry , 2009 .

[13]  Vera A. Khokhlova,et al.  Numerical modeling of finite-amplitude sound beams: Shock formation in the near field of a cw plane piston source , 2001 .

[14]  G. Harris,et al.  Progress in medical ultrasound exposimetry , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  Lawrence A Crum,et al.  Controlled tissue emulsification produced by high intensity focused ultrasound shock waves and millisecond boiling. , 2011, The Journal of the Acoustical Society of America.

[16]  V. Wilkens,et al.  Membrane hydrophone measurement and numerical simulation of HIFU fields up to developed shock regimes , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  W. K. Law,et al.  Finite amplitude effects on the thresholds for lesion production in tissues by unfocused ultrasound , 1981 .

[18]  Lawrence A Crum,et al.  Acoustic characterization of high intensity focused ultrasound fields: a combined measurement and modeling approach. , 2008, The Journal of the Acoustical Society of America.

[19]  Jeffrey C. Bamber,et al.  Physical Principles of Medical Ultrasonics: Hill/Physical Principles of Medical Ultrasonics, Second Edition , 2005 .

[20]  L. Crum,et al.  A derating method for therapeutic applications of high intensity focused ultrasound , 2010, Acoustical physics.

[21]  J E Soneson,et al.  Thresholds for nonlinear effects in high- intensity focused ultrasound propagation and tissue heating , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  Michael R Bailey,et al.  Radiation force of an arbitrary acoustic beam on an elastic sphere in a fluid. , 2013, The Journal of the Acoustical Society of America.

[23]  Vera A. Khokhlova,et al.  Effect of acoustic nonlinearity on heating of biological tissue by high-intensity focused ultrasound , 2001 .

[24]  Robin O Cleveland,et al.  Nonlinear and diffraction effects in propagation of N-waves in randomly inhomogeneous moving media. , 2011, The Journal of the Acoustical Society of America.

[25]  K. Parker,et al.  New approaches to the linear propagation of acoustic fields. , 1991, The Journal of the Acoustical Society of America.

[26]  R Souchon,et al.  Modeling of pulsed finite-amplitude focused sound beams in time domain. , 1998, The Journal of the Acoustical Society of America.

[27]  J. Tavakkoli,et al.  Modeling of nonlinear ultrasound propagation in tissue from array transducers. , 2003, The Journal of the Acoustical Society of America.

[28]  Oleg A. Sapozhnikov,et al.  Transient acoustic holography for reconstructing the particle velocity of the surface of an acoustic transducer , 2006 .

[29]  T. L. Szabo,et al.  Effects on nonlinearity on the estimation of in situ values of acoustic output parameters. , 1999, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[30]  Robin O Cleveland,et al.  Shock wave technology and application: an update. , 2011, European urology.

[31]  Gerald R. Harris,et al.  FDA regulation of clinical high intensity focused ultrasound (HIFU) devices , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[32]  E. Carstensen,et al.  Nonlinear propagation and the output indices. , 1999, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[33]  H G Trier,et al.  Rigid piston approximation for computing the transfer function and angular response of a fiber-optic hydrophone. , 2000, The Journal of the Acoustical Society of America.

[34]  P. J. Westervelt Parametric Acoustic Array , 1963 .