Ion mobility spectrometry for the detection of volatile organic compounds in exhaled breath of patients with lung cancer: results of a pilot study

Background: Analysis of exhaled breath, especially of volatile organic compounds (VOCs), is of increasing interest in the diagnosis of lung cancer. Compared with other methods of breath analysis, ion mobility spectrometry (IMS) offers a tenfold higher detection rate of VOCs. By coupling the ion mobility spectrometer with a multicapillary column as a pre-separation unit, IMS offers the advantage of an immediate twofold separation of VOCs with visualisation in a three-dimensional chromatogram. The total analysis time is about 500 s compared with gas chromatography/mass spectrometry (GC/MS) of about 1 h. It therefore seemed reasonable to test IMS in breath analysis. Methods: In a pilot study, 32 patients with lung cancer were subjected to a breath analysis by IMS. Their IMS chromatograms were compared with those of 54 healthy controls. An IMS that was built for special clinical application was used to identify characteristic peaks of VOCs which might be relevant for the diagnosis of lung cancer in exhaled air of 10 ml volume. Results: By a combination of 23 peak regions within the IMS chromatogram, patients with lung cancer, including a patient with carcinoma in situ, were classified and differentiated from healthy persons with an error rate of zero. Conclusion: Breath analysis by IMS can detect a discriminating combination of VOCs in patients with lung cancer. By pattern recognition without the need for chemical analysis of the underlying VOCs, IMS has the potential to facilitate lung cancer diagnosis.

[1]  G. Eiceman,et al.  Ion Mobility Spectrometry: Arriving on Site and Moving beyond a Low Profile , 1999, Applied spectroscopy.

[2]  H H Hill,et al.  Ion mobility spectrometry. , 1990, Analytical chemistry.

[3]  A. Sharafkhaneh,et al.  The confounding effects of thoracic gas compression on measurement of acute bronchodilator response. , 2007, American journal of respiratory and critical care medicine.

[4]  H. J. O’neill,et al.  Volatile organic compounds in exhaled air from patients with lung cancer. , 1985, Clinical chemistry.

[5]  P. J. Barnes,et al.  Exhaled breath condensate: methodological recommendations and unresolved questions , 2005, European Respiratory Journal.

[6]  J I Baumbach,et al.  Process analysis using ion mobility spectrometry , 2006, Analytical and bioanalytical chemistry.

[7]  Manuela M. Veloso,et al.  Fast and inexpensive color image segmentation for interactive robots , 2000, Proceedings. 2000 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2000) (Cat. No.00CH37113).

[8]  L. Bianchi,et al.  Exhaled volatile organic compounds in patients with non-small cell lung cancer: cross sectional and nested short-term follow-up study , 2005, Respiratory research.

[9]  X. Zhang,et al.  Investigation of volatile biomarkers in lung cancer blood using solid-phase microextraction and capillary gas chromatography-mass spectrometry. , 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[10]  M. Mcculloch,et al.  Diagnostic Accuracy of Canine Scent Detection in Early- and Late-Stage Lung and Breast Cancers , 2006, Integrative cancer therapies.

[11]  Tarek Mekhail,et al.  Diagnosis of lung cancer by the analysis of exhaled breath with a colorimetric sensor array , 2007, Thorax.

[12]  V. Ruzsanyi ANALYSIS OF HUMAN BREATH USING IMS , 2004 .

[13]  P. Mazzone,et al.  Detection of lung cancer by sensor array analyses of exhaled breath. , 2005, American journal of respiratory and critical care medicine.

[14]  R. Cataneo,et al.  Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study , 1999, The Lancet.

[15]  Jörg Ingo Baumbach,et al.  Reduction of ion mobility spectrometry data by clustering characteristic peak structures , 2006 .

[16]  S. Bader,et al.  PROCESSING ION MOBILITY SPECTROMETRY DATA TO CHARACTERIZE GROUP DIFFERENCES IN A MULTIPLE CLASS COMPARISON , 2005 .

[17]  M. Corradi,et al.  [Volatile hydrocarbons in exhaled air: preliminary data on the characteristic profile associated with lung tumors]. , 2003, Giornale italiano di medicina del lavoro ed ergonomia.

[18]  Kevin Gleeson,et al.  Detection of lung cancer with volatile markers in the breath. , 2003, Chest.

[19]  J. Stach,et al.  Ion Mobility Spectrometry - Basic Elements and Applications , 2002 .

[20]  E. Martinelli,et al.  Lung cancer identification by the analysis of breath by means of an array of non-selective gas sensors. , 2003, Biosensors & bioelectronics.

[21]  J I Baumbach,et al.  Ion mobility spectrometry in the diagnosis of sarcoidosis: results of a feasibility study. , 2007, Journal of physiology and pharmacology : an official journal of the Polish Physiological Society.

[22]  Alexander Rokitansky,et al.  Thorax , 2009, Pediatric Surgery Digest.