UPGRADED X-BAND 950 KeV LINAC X-RAY SOURCE FOR ON-SITE INSPECTION AT PETROCHEMICAL COMPLEX
暂无分享,去创建一个
Our portable X-band (9.3GHz) 950KeV Linac has been successfully upgraded. The problems of RF power oscillation, beam current oscillation and reduction and finally lack of X-ray intensity were solved by replacing the axial coupling cavities with the side-coupled ones. Designed X-ray dose rate of 0.05 Sv/min@1m is going to be achieved. Length of the accelerating tube is reduced to less than 25 cm. X-ray source part with the local radiation shielding is connected by the flexible waveguide with the box of the 250 kW magnetron and cooling unit. The total system consists of the three suit-case-size units, the last of which is one for the electric power supply. Even on-line dynamic transmission imaging is available by using the high intensity X-ray camera. Demonstration of the measurement of wall thinning of metal pipes with thick thermal shielding has been conducted with imaging plate, and artificial defects with size of 3mm, 5mm, 7mm and 10mm have been measured.