LOR-OSEM: statistical PET reconstruction from raw line-of-response histograms

Iterative statistical reconstruction methods are becoming the standard in positron emission tomography (PET). Conventional maximum-likelihood expectation-maximization (MLEM) and ordered-subsets (OSEM) algorithms act on data which have been pre-processed into corrected, evenly-spaced histograms; however, such pre-processing corrupts the Poisson statistics. Recent advances have incorporated attenuation, scatter and randoms compensation into the iterative reconstruction. The objective of this work was to incorporate the remaining pre-processing steps, including arc correction, to reconstruct directly from raw unevenly-spaced line-of-response (LOR) histograms. This exactly preserves Poisson statistics and full spatial information in a manner closely related to listmode ML, making full use of the ML statistical model. The LOR-OSEM algorithm was implemented using a rotation-based projector which maps directly to the unevenly-spaced LOR grid. Simulation and phantom experiments were performed to characterize resolution, contrast and noise properties for 2D PET. LOR-OSEM provided a beneficial noise-resolution tradeoff, outperforming AW-OSEM by about the same margin that AW-OSEM outperformed pre-corrected OSEM. The relationship between LOR-ML and listmode ML algorithms was explored, and implementation differences are discussed. LOR-OSEM is a viable alternative to AW-OSEM for histogram-based reconstruction with improved spatial resolution and noise properties.

[1]  G Bibbo,et al.  Physics in Nuclear Medicine, 3rd edition , 2005 .

[2]  Alvaro R. De Pierro,et al.  A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography , 1996, IEEE Trans. Medical Imaging.

[3]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[4]  E U Mumcuoğlu,et al.  Bayesian reconstruction of PET images: methodology and performance analysis. , 1996, Physics in medicine and biology.

[5]  W. W. Moses,et al.  List-mode maximum-likelihood reconstruction applied to positron emission mammography (PEM) with irregular sampling , 2000, IEEE Transactions on Medical Imaging.

[6]  William P. Segars,et al.  A realistic spline-based dynamic heart phantom , 1998 .

[7]  Lucas C. Parra,et al.  List-Mode Likelihood EM Algorithm and Noise Estimation Demonstrated on 2D-PET , 1998, IEEE Trans. Medical Imaging.

[8]  K. Lange,et al.  EM reconstruction algorithms for emission and transmission tomography. , 1984, Journal of computer assisted tomography.

[9]  K. Erlandsson,et al.  Fast accurate iterative reconstruction for low-statistics positron volume imaging. , 1998, Physics in medicine and biology.

[10]  T. Hebert,et al.  Fast methods for including attenuation in the EM algorithm , 1990 .

[11]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[12]  C. Comtat,et al.  Fast reconstruction of 3-D PET data with accurate statistical modeling , 1997 .

[13]  S R Meikle,et al.  A convolution-subtraction scatter correction method for 3D PET. , 1994, Physics in medicine and biology.

[14]  H H Barrett,et al.  List-mode likelihood. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[15]  Charles L. Byrne,et al.  Likelihood maximization for list-mode emission tomographic image reconstruction , 2001, IEEE Transactions on Medical Imaging.

[16]  Michael Zibulevsky,et al.  The Design and Implementation of COSEM, an Iterative Algorithm for Fully 3D Listmode Data , 2001, IEEE Trans. Medical Imaging.

[17]  S. Cherry,et al.  Physics in Nuclear Medicine , 2004 .

[18]  Dan J Kadrmas,et al.  Comparative evaluation of lesion detectability for 6 PET imaging platforms using a highly reproducible whole-body phantom with (22)Na lesions and localization ROC analysis. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  Michael A. King,et al.  LMIRA: list mode iterative reconstruction algorithm for SPECT , 2000 .

[20]  Michel Defrise,et al.  Data Acquisition and Image Reconstruction for 3D PET , 1998 .

[21]  R. W. Schafer,et al.  A comparison of rotation-based methods for iterative reconstruction algorithms , 1995 .

[22]  Alan W. Paeth,et al.  A fast algorithm for general raster rotation , 1986 .

[23]  Charles L. Byrne,et al.  Block-iterative methods for image reconstruction from projections , 1996, IEEE Trans. Image Process..