Dynamic contact stress analysis using a compliant sensor array

Abstract A flexible sensor array has been developed for the measurement of contact stress distribution between flexible bodies. The array incorporates 960 contact geometry modulation resistive (CGMR) transducers to provide a spatial resolution of 10 mm × 10 mm. The high flexibility of the array and its special structure enable it to comply with the very large displacements of the interface between the human body and a flexible cushion. In addition, a method and instrument have been developed to measure, digitize and record dynamic contact stress distributions with a sampling rate of up to 300 frames per second (960 sensors/frame). Measurements performed using this system under static and dynamic conditions are consistent with those performed through the contact pressure display (CPD) method. The new method has been used by the authers and their associates to obtain basic data required for the new field of cushioning mechanics.

[1]  J D Troup,et al.  Driver's back pain and its prevention. A review of the postural, vibratory and muscular factors, together with the problem of transmitted road-shock. , 1978, Applied ergonomics.

[2]  S P Nigam,et al.  A study on a vibratory model of a human body. , 1987, Journal of biomechanical engineering.

[3]  M Arcan,et al.  A fundamental characteristic of the human body and foot, the foot-ground pressure pattern. , 1976, Journal of biomechanics.

[4]  A. Voloshin,et al.  An in vivo study of low back pain and shock absorption in the human locomotor system. , 1982, Journal of biomechanics.

[5]  H. Von Gierke,et al.  Reappraisal of biodynamic implications of human ejections. , 1968, Aerospace medicine.

[6]  Wing Commander F. Latham A study in body ballistics: seat ejection , 1957, Proceedings of the Royal Society of London. Series B - Biological Sciences.

[7]  R M Rose,et al.  The response of joints to impact loading. II. In vivo behavior of subchondral bone. , 1972, Journal of biomechanics.

[8]  R J Minns,et al.  Pressures under the ischium detected by a pedobarograph. , 1982, Engineering in medicine.

[9]  P R Cavanagh,et al.  A technique for the display of pressure distributions beneath the foot. , 1980, Journal of biomechanics.

[10]  C D Nash,et al.  A model for the response of seated humans to sinusoidal displacements of the seat. , 1974, Journal of biomechanics.

[11]  Mircea Arcan,et al.  Application of the Contact Pressure Display (CPD) Method to Tire Mechanics , 1985 .

[12]  William S. Marras,et al.  Measurement of Seat Pressure Distributions , 1987 .

[13]  G V Cochran,et al.  Wheelchair cushion modification: device for locating high-pressure regions. , 1981, Archives of physical medicine and rehabilitation.

[14]  M. A. Brull,et al.  An experimental approach to the contact problem between flexible and rigid bodies , 1980 .

[15]  W.J. Tompkins,et al.  An umbilical data-acquisition system for measuring pressures between the foot and shoe , 1990, IEEE Transactions on Biomedical Engineering.

[16]  Ronald S. Fearing,et al.  Basic solid mechanics for tactile sensing , 1984, ICRA.

[17]  J Sandover,et al.  Dynamic Loading as a Possible Source of Low-Back Disorders , 1983, Spine.

[18]  I. Paul,et al.  Response of joints to impact loading. 3. Relationship between trabecular microfractures and cartilage degeneration. , 1973, Journal of biomechanics.

[19]  T. D. Brown,et al.  Miniature piezoresistive transducers for transient soft-body contact-stress problems , 1979 .

[20]  J E Hansson,et al.  Vibration in car repair work. , 1987, Applied ergonomics.

[21]  Lim Kah-Bin,et al.  Low cost tactile gripper using silicone rubber sensor array , 1988 .

[22]  R. Soames Foot pressure patterns during gait. , 1985, Journal of biomedical engineering.

[23]  Garber Sl,et al.  Wheelchair cushion modification and its effect on pressure. , 1984 .