Comparing filtered backprojection and ordered-subsets expectation maximization for small-lesion detection and localization in 67Ga SPECT.

UNLABELLED Iterative reconstruction of SPECT images has recently become clinically available as an alternative to filtered backprojection (FBP). However, there is conflicting evidence on whether iterative reconstruction, such as with the ordered-subsets expectation maximization (OSEM) algorithm, improves diagnostic performance over FBP. The study objective was to determine if the detection and localization of small lesions in simulated thoracic gallium SPECT images are better with OSEM reconstruction than with FBP, both with and without attenuation correction (AC). METHODS Images were simulated using an analytic projector acting on the mathematic cardiac torso computer phantom. Perfect scatter rejection was assumed. Lesion detection accuracy was assessed using localization receiver operating characteristic methodology. The images were read by 5 nuclear medicine physicians. For each reconstruction strategy and for each observer, data were collected in 2 viewing sessions of 100 images. Two-way ANOVA and, when indicated, the Scheffé multiple comparisons test were applied to check for significant differences. RESULTS Little difference in the accuracy of detection or localization was seen between FBP with and without AC. OSEM with AC extended the contrast range for accurate lesion detection and localization over that of the other methods investigated. Without AC, no significant difference between OSEM and FBP reconstruction was detected. CONCLUSION OSEM with AC may improve the detection and localization of thoracic gallium-labeled lesions over FBP reconstruction.

[1]  C E Metz,et al.  An evaluation of maximum likelihood-expectation maximization reconstruction for SPECT by ROC analysis. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  Benjamin M. W. Tsui,et al.  Noise properties of filtered-backprojection and ML-EM reconstructed emission tomographic images , 1992 .

[3]  Ronald J. Jaszczak,et al.  ROC evaluation of SPECT myocardial lesion detectability with and without single iteration non-uniform Chang attenuation compensation using an anthropomorphic female phantom , 1998 .

[4]  P F Judy,et al.  Evaluation of video gray-scale display. , 1992, Medical physics.

[5]  B. Tsui,et al.  Noise properties of the EM algorithm: II. Monte Carlo simulations. , 1994, Physics in medicine and biology.

[6]  R. M. Kniseley,et al.  Distribution of gallium in human tissues after intravenous administration. , 1972, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  M F Kijewski,et al.  SPECT image noise power: effects of nonstationary projection noise and attenuation compensation. , 1988, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  K Kubota,et al.  Lesion-to-background ratio in nonattenuation-corrected whole-body FDG PET images. , 1998, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  E C Frey,et al.  Receiver operating characteristic evaluation of iterative reconstruction with attenuation correction in 99mTc-sestamibi myocardial SPECT images. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  Philip F. Judy,et al.  Nodule polarity effects on detection and localization performance in liver CT images , 1997, Medical Imaging.

[11]  M A King,et al.  Effect of filtering on the detection and localization of small Ga-67 lesions in thoracic single photon emission computed tomography images. , 1999, Medical physics.

[12]  C E Metz,et al.  Some practical issues of experimental design and data analysis in radiological ROC studies. , 1989, Investigative radiology.

[13]  S. Reske,et al.  Role of attenuation correction for fluorine-18 fluorodeoxyglucose positron emission tomography in the primary staging of malignant lymphoma , 1999, European Journal of Nuclear Medicine.

[14]  Philip F. Judy,et al.  Maximizing the detection and localization of Ga-67 tumors in thoracic SPECT MLEM (OSEM) reconstructions , 1998 .

[15]  R. Swensson Unified measurement of observer performance in detecting and localizing target objects on images. , 1996, Medical physics.

[16]  B F Hutton,et al.  Accelerated EM reconstruction in total-body PET: potential for improving tumour detectability. , 1994, Physics in medicine and biology.

[17]  James E. Bowsher,et al.  Improved lesion detection in SPECT using MLEM reconstruction , 1990 .

[18]  B M Tsui,et al.  Evaluation of cardiac cone-beam single photon emission computed tomography using observer performance experiments and receiver operating characteristic analysis. , 1993, Investigative radiology.

[19]  Matt A. King,et al.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 2. Attenuation compensation algorithms , 1996, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[20]  E. K. J. Pauwels,et al.  Role of 67Ga scintigraphy in localization of lymphoma , 1996, Annals of Hematology.

[21]  R. E. Zimmerman,et al.  GALLIUM-67 IMAGE CONTRAST: RELATIONSHIP TO ENERGY PEAK AND WINDOW WIDTH SELECTION , 1995 .

[22]  Lee-Tzuu Chang,et al.  A Method for Attenuation Correction in Radionuclide Computed Tomography , 1978, IEEE Transactions on Nuclear Science.

[23]  Michael A. King,et al.  Attenuation correction strategies for multi-energy photon emitters using SPECT , 1996 .

[24]  A. D. Van den Abbeele,et al.  Procedure guideline for gallium scintigraphy in the evaluation of malignant disease. Society of Nuclear Medicine. , 1997, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[25]  Alan G. Hawkes,et al.  A handbook of numerical and statistical techniques , 1977 .

[26]  Harrison H. Barrett,et al.  Attenuation, noise, and image quality in single-photon emission computed tomography , 1994 .

[27]  M. King,et al.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 1. Impact of attenuation and methods of estimating attenuation maps , 1995, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[28]  Eric C. Frey,et al.  Quantitative cardiac SPECT reconstruction with reduced image degradation due to patient anatomy , 1993 .

[29]  Scott T. Grafton,et al.  Results of a clinical receiver operating characteristic study comparing filtered backprojection and maximum likelihood estimator images in FDG PET studies. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.