Design, analysis and experiments of a spatial universal rotating magnetic field system for capsule robot

For non-contact drive of capsule micro robot in bending intestine, we propose a technical scheme in which three axis orthogonal square Helmholtz coils are employed to generate a spatial universal outer rotating uniform magnetic field using magnetic field superposition principle. For their optimization design, electromagnetic mathematical model of the three axis Helmholtz coils system is derived to analyse the electromagnetic dynamic characteristics with respect to their structural parameters. Theoretical research and simulations show that the axial orientation of rotating magnetic field can be adjusted in response to currents applied to three axis Helmholtz coils, and superimposed magnetic field features good uniformity and directivity. Finally, the uniformity and directivity of magnetic field are verified through experiments, which can drive capsule robot forward inside bending pipe. The technology for generating spatial universal rotating magnetic field provides a possible solution for non-contact drive of capsule micro robot in bending intestine, which has a promising application prospect in medical engineering.

[1]  Yongshun Zhang,et al.  A Variable-Diameter Capsule Robot Based on Multiple Wedge Effects , 2011, IEEE/ASME Transactions on Mechatronics.

[2]  HongHai Yu,et al.  Dynamic characteristics of an intestine capsule robot with variable diameter , 2010 .

[3]  Max Q.-H. Meng,et al.  Active actuation system of wireless capsule endoscope based on magnetic field , 2007, 2007 IEEE International Conference on Robotics and Biomimetics (ROBIO).

[4]  Gabriele Grandi,et al.  Magnetic-field transducer based on closed-loop operation of magnetic sensors , 2006, IEEE Transactions on Industrial Electronics.

[5]  Chen Gu,et al.  Square Helmholtz coil with homogeneous field for magnetic measurement of longer HTS tapes , 2005 .

[6]  Massimiliano Pastena,et al.  Optimum design of a three-axis magnetic field simulator , 2002 .

[7]  Sijiong Zhang,et al.  An improved Helmholtz coil and analysis of its magnetic field homogeneity , 2002 .

[8]  Paul Swain,et al.  Wireless capsule endoscopy of the small bowel: development, testing, and first human trials , 2001, European Conference on Biomedical Optics.

[9]  G. Meron The development of the swallowable video capsule (M2A). , 2000, Gastrointestinal endoscopy.

[10]  Marian K. Kazimierczuk,et al.  Self-capacitance of inductors , 1997 .

[11]  A. Massarini,et al.  Lumped parameter models for single- and multiple-layer inductors , 1996, PESC Record. 27th Annual IEEE Power Electronics Specialists Conference.

[12]  Allan H. Robbins,et al.  Circuit Analysis: Theory and Practice , 1995 .

[13]  S. R. Trout,et al.  Use of Helmholtz coils for magnetic measurements , 1988 .

[14]  D. F. Warne,et al.  Newnes Electrical Power Engineer's Handbook , 2000 .

[15]  G. G. Karady,et al.  Comparison of calibration systems for magnetic field measurement equipment , 1994 .

[16]  F. Young,et al.  Fields in square helmholtz coils , 1961 .