Flow Diverting Stents in Cerebral Small Caliber Vessels (< 2 mm) for Aneurysm Treatment

[1]  Min S. Park,et al.  Flow Diverter Devices for Treatment of Intracranial Aneurysms in Small Parent Vessels - A Systematic Review of Literature. , 2022, World neurosurgery.

[2]  I. Saatci,et al.  Safety and Efficacy of the FRED Jr Flow Re-Direction Endoluminal Device for Intracranial Aneurysms: Retrospective Multicenter Experience With Emphasis on Midterm Results , 2021, Frontiers in Neurology.

[3]  I. Saatci,et al.  Long-term clinical and angiographic follow-up results of the dual-layer flow diverter device (FRED) for the treatment of intracranial aneurysms in a multicenter study , 2021, Neuroradiology.

[4]  N. Kocer,et al.  Long-term safety and efficacy of distal aneurysm treatment with flow diversion in the M2 segment of the middle cerebral artery and beyond , 2020, Journal of NeuroInterventional Surgery.

[5]  G. Carrafiello,et al.  Branch vessel occlusion in aneurysm treatment with flow diverter stent , 2020, Acta bio-medica : Atenei Parmensis.

[6]  D. Kallmes,et al.  Mechanism of Action and Biology of Flow Diverters in the Treatment of Intracranial Aneurysms. , 2019, Neurosurgery.

[7]  E. Boccardi,et al.  FRED Italian Registry: a multicenter experience with the flow re-direction endoluminal device for intracranial aneurysms. , 2020, Journal of neurosurgery.

[8]  R. Tamargo,et al.  Tiny Pipes: 67 Cases of Flow Diversion for Aneurysms in Distal Vessels Measuring Less Than 2.0 mm. , 2019, World neurosurgery.

[9]  A. Bonafe,et al.  Treatment of Unruptured Distal Anterior Circulation Aneurysms with Flow-Diverter Stents: A Meta-Analysis , 2019, American Journal of Neuroradiology.

[10]  A. Bonafe,et al.  Treatment of Distal Anterior Cerebral Artery Aneurysms with Flow-Diverter Stents: A Single-Center Experience , 2018, American Journal of Neuroradiology.

[11]  Qinghai Huang,et al.  Safety and Efficacy of Flow Diverter Treatment for Aneurysm in Small Cerebral Vessels: A Systematic Review and Meta-Analysis. , 2018, World neurosurgery.

[12]  D. Rex,et al.  Pipeline Embolization Device for Pericallosal Artery Aneurysms: A Retrospective Single Center Safety and Efficacy Study. , 2018, Operative neurosurgery.

[13]  I. Saatci,et al.  Multicenter Experience with FRED Jr Flow Re-Direction Endoluminal Device for Intracranial Aneurysms in Small Arteries , 2017, American Journal of Neuroradiology.

[14]  E. Raz,et al.  Treatment of distal anterior cerebral artery aneurysms with the Pipeline Embolization Device , 2017, Journal of Clinical Neuroscience.

[15]  H. Woo,et al.  Long-Term Clinical and Angiographic Outcomes Following Pipeline Embolization Device Treatment of Complex Internal Carotid Artery Aneurysms: Five-Year Results of the Pipeline for Uncoilable or Failed Aneurysms Trial , 2017, Neurosurgery.

[16]  Justin M. Moore,et al.  Use of Platelet Function Testing Before Pipeline Embolization Device Placement: A Multicenter Cohort Study , 2017, Stroke.

[17]  J. Grossberg,et al.  Treatment of complex anterior cerebral artery aneurysms with Pipeline flow diversion: mid-term results , 2016, Journal of NeuroInterventional Surgery.

[18]  C. Ogilvy,et al.  Treatment of Distal Anterior Circulation Aneurysms With the Pipeline Embolization Device: A US Multicenter Experience. , 2016, Neurosurgery.

[19]  P. Liu,et al.  Flow-diverter devices in the treatment of intracranial aneurysms: A meta-analysis and systematic review , 2016, The neuroradiology journal.

[20]  A. Wakhloo,et al.  Safety, efficacy, and short-term follow-up of the use of Pipeline™ Embolization Device in small (<2.5mm) cerebral vessels for aneurysm treatment: single institution experience , 2016, Neuroradiology.

[21]  D. Kallmes,et al.  Platelet Testing is Associated with Worse Clinical Outcomes for Patients Treated with the Pipeline Embolization Device , 2015, American Journal of Neuroradiology.

[22]  A. Brunetti,et al.  Endovascular treatment of cerebral aneurysms using flow-diverter devices: A systematic review , 2015, The neuroradiology journal.

[23]  F. Caire,et al.  Flow-diverting stents for intracranial bifurcation aneurysm treatment. , 2014, Neurosurgery.

[24]  G. Dabus,et al.  Pipeline endovascular device for the treatment of intracranial aneurysms at the level of the circle of Willis and beyond: multicenter experience , 2014, Journal of NeuroInterventional Surgery.

[25]  D. Kallmes,et al.  Acute branch occlusion after Pipeline embolization of intracranial aneurysms , 2014, Journal of Clinical Neuroscience.

[26]  B. Crandall,et al.  Last-Recorded P2Y12 Reaction Units Value Is Strongly Associated with Thromboembolic and Hemorrhagic Complications Occurring Up to 6 Months after Treatment in Patients with Cerebral Aneurysms Treated with the Pipeline Embolization Device , 2014, American Journal of Neuroradiology.

[27]  R. Sarabia,et al.  Flow-diverter devices for intracranial aneurysms: systematic review and meta-analysis. , 2013, Neurosurgery.

[28]  T. Krings,et al.  A Novel Grading Scale for the Angiographic Assessment of Intracranial Aneurysms Treated Using Flow Diverting Stents , 2010, Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences.