The laser-based gain monitoring system of the calorimeters in the Muon g−2 experiment at Fermilab

The Muon $g-2$ experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifying the current discrepancy with the theoretical prediction. A central component of this four-fold improvement in precision is the laser calibration system of the calorimeters, which has to monitor the gain variations of the photo-sensors with a 0.04\% precision on the short-term ($\sim 1\,$ms). This is about one order of magnitude better than what has ever been achieved for the calibration of a particle physics calorimeter. The system is designed to monitor also long-term gain variations, mostly due to temperature effects, with a precision below the per mille level. This article reviews the design, the implementation and the performance of the Muon $g-2$ laser calibration system, showing how the experimental requirements have been met.

[1]  C. Rogan Laser monitoring for the CMS ECAL , 2010 .

[2]  Final report of the E821 muon anomalous magnetic moment measurement at BNL , 2006, hep-ex/0602035.

[3]  T. Teubner,et al.  The Muon (g-2) Theory Value: Present and Future , 2013, 1311.2198.

[4]  D. Hertzog Next Generation Muon g − 2 Experiments , 2015, 1512.00928.

[5]  M. Strikhanov,et al.  Geant4 simulations of the lead fluoride calorimeter , 2016, 1611.10272.

[6]  G. Pauletta,et al.  Performance of the Muon g−2 calorimeter and readout systems measured with test beam data , 2019, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment.

[7]  S. Mastroianni The Readout Controller for the Calibration System of the Muon g-2 Experiment , 2018, IEEE Transactions on Nuclear Science.

[8]  Masaaki Kobayashi,et al.  An NaI(Tl)-241Am high reliability, constant amplitude light pulser , 1981 .

[9]  B. Roberts Lepton Dipole Moments , 2003, hep-ex/0309010.

[10]  M. C. V. Woerden Upgrade of the Laser calibration system for the ATLAS hadronic calorimeter TileCal , 2016 .

[11]  W. Morse,et al.  The New (g-2) Experiment: A proposal to measure the muon anomalous magnetic moment to +-0.14 ppm precision , 2009 .

[12]  P. Alam ‘E’ , 2021, Composites Engineering: An A–Z Guide.

[13]  F. Jegerlehner The Anomalous Magnetic Moment of the Muon , 2007 .

[14]  F. Bedeschi,et al.  Electron beam test of key elements of the laser-based calibration system for the muon g - 2 experiment , 2016, 1610.03210.

[15]  M. Xiao,et al.  Laser calibration system in JUNO , 2018, Journal of Instrumentation.

[16]  D. Cauz,et al.  Test of candidate light distributors for the muon (g−2) laser calibration system , 2015, 1504.00132.

[17]  D. Cauz,et al.  Studies of an array of PbF 2 Cherenkov crystals with large-area SiPM readout , 2014, 1412.5525.

[18]  L. Gibbons,et al.  Design and performance of SiPM-based readout of PbF2 crystals for high-rate, precision timing applications , 2016, 1611.03180.

[19]  Measurement of the negative muon anomalous magnetic moment to 0.7 ppm. , 2002, Physical review letters.

[20]  F. Bedeschi,et al.  The monitoring electronics of the laser calibration system in the Muon g-2 experiment , 2019, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment.

[21]  F. Bedeschi,et al.  The laser control of the muon g−2 experiment at Fermilab , 2018 .