An air quality data analysis system for interrelating effects, standards and needed source reductions.

Forced expiratory volume in 1 second (FEV1) was measured in 21 men exercising while exposed to four O3 concentrations (0.0, 0.08, 0.10, and 0.12 ppm). A lognormal multiple linear regression model was fitted to their mean FEV1 measurements to predict FEV1 percent decrease as a function of O3 concentration and exposure duration. The exercise level used was probably comparable to heavy manual labor. The longest O3 exposure studied was 6 h. Extrapolating cautiously to an 8-h workday of heavy manual labor, the model predicts that O3 concentrations of 0.08, 0.10, and 0.12 ppm would decrease FEV1 by 9, 15, and 20 percent, respectively.