Electrostatic microactuators for precise positioning of neural microelectrodes

Microelectrode arrays used for monitoring single and multineuronal action potentials often fail to record from the same population of neurons over a period of time likely due to micromotion of neurons away from the microelectrode, gliosis around the recording site and also brain movement due to behavior. We report here novel electrostatic microactuated microelectrodes that will enable precise repositioning of the microelectrodes within the brain tissue. Electrostatic comb-drive microactuators and associated microelectrodes are fabricated using the SUMMiT V/spl trade/ (Sandia's Ultraplanar Multilevel MEMS Technology) process, a five-layer polysilicon micromachining technology of the Sandia National labs, NM. The microfabricated microactuators enable precise bidirectional positioning of the microelectrodes in the brain with accuracy in the order of 1 /spl mu/m. The microactuators allow for a linear translation of the microelectrodes of up to 5 mm in either direction making it suitable for positioning microelectrodes in deep structures of a rodent brain. The overall translation was reduced to approximately 2 mm after insulation of the microelectrodes with epoxy for monitoring multiunit activity. The microactuators are capable of driving the microelectrodes in the brain tissue with forces in the order of several micro-Newtons. Single unit recordings were obtained from the somatosensory cortex of adult rats in acute experiments demonstrating the feasibility of this technology. Further optimization of the insulation, packaging and interconnect issues will be necessary before this technology can be validated in long-term experiments.

[1]  H Petsche,et al.  A 16-fold semi-microelectrode for intracortical recording of field potentials. , 1979, Electroencephalography and clinical neurophysiology.

[2]  F. A. Wilson,et al.  A microelectrode drive for long term recording of neurons in freely moving and chaired monkeys , 2003, Journal of Neuroscience Methods.

[3]  R. S. Pickard,et al.  A review of printed circuit microelectrodes and their production , 1979, Journal of Neuroscience Methods.

[4]  K. Najafi,et al.  Scaling limitations of silicon multichannel recording probes , 1990, IEEE Transactions on Biomedical Engineering.

[5]  W.L.C. Rutten,et al.  Neuro-electronic interfacing with multielectrode arrays , 1999, IEEE Engineering in Medicine and Biology Magazine.

[6]  K. Wise,et al.  A Multichannel Depth Probe Fabricated Using Electron-Beam Lithography , 1979, IEEE Transactions on Biomedical Engineering.

[7]  Mircea Modreanu,et al.  Micromachining of a silicon multichannel microprobe for neural electrical activity recording , 2002 .

[8]  K. Moxon,et al.  Ceramic-based multisite microelectrodes for electrochemical recordings. , 2000, Analytical chemistry.

[9]  M. Kuperstein,et al.  A Practical 24 Channel Microelectrode for Neural Recording in Vivo , 1981, IEEE Transactions on Biomedical Engineering.

[10]  M. S. Rodgers,et al.  Failure modes in surface micromachined microelectromechanical actuators , 1998, 1998 IEEE International Reliability Physics Symposium Proceedings. 36th Annual (Cat. No.98CH36173).

[11]  Michale S Fee,et al.  Miniature motorized microdrive and commutator system for chronic neural recording in small animals , 2001, Journal of Neuroscience Methods.

[12]  R. J. Vetter,et al.  Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex , 2003, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[13]  Heribert J. P. Reitboeck,et al.  A 19-channel matrix drive with individually controllable fiber microelectrodes for neurophysiological applications , 1983, IEEE Transactions on Systems, Man, and Cybernetics.

[14]  Matthew M. Holecko,et al.  In vitro assessment of bioactive coatings for neural implant applications. , 2004, Journal of biomedical materials research. Part A.

[15]  B L McNaughton,et al.  Dynamics of the hippocampal ensemble code for space. , 1993, Science.

[16]  Justin C. Williams,et al.  Flexible polyimide-based intracortical electrode arrays with bioactive capability , 2001, IEEE Transactions on Biomedical Engineering.

[17]  H. J. Reitböck,et al.  Multi-electrode recording system for the study of spatio-temporal activity patterns of neurons in the central nervous system , 1983, Experientia.

[18]  H. Eichenbaum,et al.  Extracellular neural recording with multichannel microelectrodes , 1986 .

[19]  David J. Anderson,et al.  Solid-State Electrodes for Multichannel Multiplexed Intracortical Neuronal Recording , 1986, IEEE Transactions on Biomedical Engineering.

[20]  Nathan Jackson,et al.  Single neuronal recordings using surface micromachined polysilicon microelectrodes , 2005, Journal of Neuroscience Methods.

[21]  K. Wise,et al.  An integrated-circuit approach to extracellular microelectrodes. , 1970, IEEE transactions on bio-medical engineering.

[22]  J. Sniegowski Multi-level polysilicon surface-micromachining technology: Applications and issues , 1996 .

[23]  R. Eckhorn,et al.  A new method for the insertion of multiple microprobes into neural and muscular tissue, including fiber electrodes, fine wires, needles and microsensors , 1993, Journal of Neuroscience Methods.

[24]  J. E. Wood,et al.  The wobble motor: an electrostatic, planetary-armature, microactuator , 1989, IEEE Micro Electro Mechanical Systems, , Proceedings, 'An Investigation of Micro Structures, Sensors, Actuators, Machines and Robots'.

[25]  Zoran Nenadic,et al.  Semi-chronic motorized microdrive and control algorithm for autonomously isolating and maintaining optimal extracellular action potentials. , 2005, Journal of neurophysiology.

[26]  Ernest J. Garcia,et al.  Surface micromachined microengine , 1995 .

[27]  V. Mountcastle,et al.  Adaptation of the Reitboeck method of multiple microelectrode recording to the neocortex of the waking monkey , 1991, Journal of Neuroscience Methods.