Corneal-tissue absorption coefficients for 193- and 213-nm ultraviolet radiation.

The small-signal absorption coefficients of 193- and 213-nm nanosecond laser pulses in bovine corneal tissue have been studied. The absolute reflectance of a planar quartz-cornea interface was measured at various angles of incidence for low-intensity laser irradiation (i.e., pulse fluences 3 orders of magnitude below the ablation threshold). The reflectance-versus-angle data were analyzed by the use of Fresnel theory to estimate the effective complex index of refraction of the tissue. This analysis indicated corneal absorption coefficients of 39,900 ± 9800 cm(-1) at 193 nm and 21,400 ± 4900 cm(-1) at 213 nm.

[1]  N. Nishioka,et al.  The thermodynamic response of soft biological tissues to pulsed ultraviolet laser irradiation. , 1995, Biophysical journal.

[2]  M. Ediger,et al.  Dynamic optical properties of collagen-based tissue during ArF excimer laser ablation. , 1993, Applied optics.

[3]  R. P. Weiblinger,et al.  Excimer laser ablation of the cornea , 1995 .

[4]  I J Constable,et al.  Bovine corneal stroma ablation rate with 193-nm excimer laser radiation: quantitative measurement. , 1990, Refractive & corneal surgery.

[5]  I. Kochevar,et al.  Cytotoxicity and mutagenicity of excimer laser radiation , 1989, Lasers in surgery and medicine.

[6]  J. Parel,et al.  Ultraviolet solid-state laser (213-nm) photorefractive keratectomy. In vitro study. , 1993, Ophthalmology.

[7]  G. M. Hale,et al.  Optical Constants of Water in the 200-nm to 200-microm Wavelength Region. , 1973, Applied optics.

[8]  G. Benedek,et al.  Theory of transparency of the eye. , 1971, Applied optics.

[9]  E. Arakawa,et al.  Optical Measurements of Liquid Water in the Vacuum Ultraviolet , 1969 .

[10]  R. Rockafellar The multiplier method of Hestenes and Powell applied to convex programming , 1973 .

[11]  M. Geis,et al.  Self‐developing UV photoresist using excimer laser exposure , 1983 .

[12]  C. Puliafito,et al.  Quantitative and ultrastructural studies of excimer laser ablation of the cornea at 193 and 248 nanometers , 1987, Lasers in surgery and medicine.

[13]  M. Ediger,et al.  Pump/probe transmission measurements of corneal tissue during excimer laser ablation , 1993, Lasers in surgery and medicine.

[14]  F Hillenkamp,et al.  Excimer laser ablation of the cornea and lens. Experimental studies. , 1985, Ophthalmology.

[15]  R R Krueger,et al.  Quantitation of corneal ablation by ultraviolet laser light. , 1985, Archives of ophthalmology.

[16]  G. Na UV spectroscopic characterization of type I collagen. , 1988, Collagen and related research.

[17]  M. Kitai,et al.  The physics of UV laser cornea ablation , 1991 .

[18]  D. Maurice,et al.  The Cornea and Sclera , 1962 .

[19]  G O Waring,et al.  Effect of excimer laser radiant exposure on uniformity of ablated corneal surface , 1989, Lasers in surgery and medicine.

[20]  H Zauberman,et al.  Controlled lens formation with unapertured excimer lasers: use with organic polymers and corneal tissues. , 1990, Applied optics.

[21]  A. Vogel,et al.  Optical properties of human sclera, and their consequences for transscleral laser applications , 1991, Lasers in surgery and medicine.

[22]  M. Ediger,et al.  Enhanced ArF laser absorption in a collagen target under ablative conditions , 1994, Lasers in surgery and medicine.

[23]  J. Olivo,et al.  Excimer laser surgery of the cornea: Qualitative and quantitative aspects of photoablation according to the energy density , 1986, Journal of cataract and refractive surgery.

[24]  Michael W. Berns,et al.  Laser refractive surgery: a review and current status , 1995 .