Biomechanical comparison of four anterior atlantoaxial plate systems.

OBJECT The optimum fixation method to achieve atlantoaxial fusion after resection of the odontoid process remains a matter of discussion. Anterior atlantoaxial plate fixation has been described by Harms as a fixation procedure to be performed after transoral odontoid resection. In recent biomechanical and clinical studies investigators have shown that this procedure is a good alternative to established posterior atlantoaxial fixation techniques, but they have also indicated the biomechanical disadvantages of the Harms plate design. Therefore, three new anterior atlantoaxial plate designs were developed. The purpose of this study was to compare these three newly designed plate systems biomechanically with that used in Harms anterior atlantoaxial plate fixation. METHODS Twenty-four human craniocervical cadaveric specimens were tested in flexion, extension, axial rotation, and lateral bending in a nonconstrained testing apparatus by using a nondestructive stiffness method. Three-dimensional displacement of C 1-2 was measured with an optical measurement system. Six different groups were examined: 1) control (24 specimens); 2) unstable (after odontoidectomy and dissection of the atlantoaxial ligaments; 24 specimens); 3) Harms (anterior atlantoaxial plate fixation according to Harms; six specimens); 4) subarticular atlantoaxial plate (SAAP; six specimens); 5) transpedicular atlantoaxial plate (TAAP; six specimens); and 6) subarticular atlantoaxial locking plate (SAALP; six specimens). Stiffness, range of motion, and neutral and elastic zones were determined. Compared with the Harms plate, stiffness was significantly higher when methods for placing the SAAP, TAAP, and SAALP devices were used (p < 0.05). Angular displacement of SAALPs was less than that demonstrated in any other group (p < 0.05). Stiffness values in any direction were significantly greater for the SAALP-fixed specimens than for the TAAP, SAAP, Harms, control, or unstable specimens (p < 0.05). CONCLUSIONS Experimentally, the SAAP, TAAP, and Harms plate achieved less stable fixation than the SAALP. Therefore, if transoral odontoid resection is performed, SAALP-fixed spines will provide significantly improved stability compared with previous fixation devices and methods. This may be a necessary prerequisite for a fast and uneventful osseous fusion even without additional posterior stabilization.

[1]  T. Mittlmeier,et al.  Screw placement in transoral atlantoaxial plate systems: an anatomical study. , 2001, Journal of neurosurgery.

[2]  T. Mittlmeier,et al.  Comparison Between Sheep and Human Cervical Spines: An Anatomic, Radiographic, Bone Mineral Density, and Biomechanical Study , 2001, Spine.

[3]  T. Mittlmeier,et al.  Transoral Decompression, Anterior Plate Fixation, and Posterior Wire Fusion for Irreducible Atlantoaxial Kyphosis in Rheumatoid Arthritis , 2000, Spine.

[4]  T. Mittlmeier,et al.  Biomechanical Assessment of Transoral Plate Fixation for Atlantoaxial Instability , 2000, Spine.

[5]  C. Petersilge,et al.  Morphologic Considerations of C2 Isthmus Dimensions for the Placement of Transarticular Screws , 2000, Spine.

[6]  T. Mittlmeier,et al.  Stage-related surgery for cervical spine instability in rheumatoid arthritis , 1999, European Spine Journal.

[7]  Volker K. H. Sonntag,et al.  Biomechanical Comparison of C1‐C2 Posterior Fixations: Cable, Graft, and Screw Combinations , 1998, Spine.

[8]  D. Sell,et al.  Pediatric transoral surgery: indications, complications, and long-term outcome. , 1996, Journal of neurosurgery.

[9]  E. Koeneman,et al.  An Apparatus for Applying Pure Nonconstraining Moments to Spine Segments In Vitro , 1995, Spine.

[10]  T. Ryken,et al.  Assessment of Unicortical and Bicortical Fixation in a Quasistatic Cadaveric Model: Role of Bone Mineral Density and Screw Torque , 1995, Spine.

[11]  L. Lenke,et al.  Analysis of Pulmonary Function and Chest Cage Dimension Changes After Thoracoplasty in Idiopathic Scoliosis , 1995, Spine.

[12]  S. Cook,et al.  Effects of Bone Mineral Density on Pedicle Screw Fixation , 1994, Spine.

[13]  M. Panjabi The stabilizing system of the spine. Part II. Neutral zone and instability hypothesis. , 1992, Journal of spinal disorders.

[14]  Sanchez Martin Mm Occipital-cervical instability. , 1992 .

[15]  A. Goel Transoral approach for removal of intradural lesions at the craniocervical junction. , 1991, Neurosurgery.

[16]  M. Hadley,et al.  The transoral approach to the superior cervical spine. A review of 53 cases of extradural cervicomedullary compression. , 1989, Journal of neurosurgery.

[17]  E. Dehoux,et al.  Atlanto-axial Fixation. A Biomechanical Study with CD Instrumentation , 1989 .

[18]  J. Vangilder,et al.  Transoral-transpharyngeal approach to the anterior craniocervical junction. Ten-year experience with 72 patients. , 1988, Journal of neurosurgery.

[19]  F. Magerl,et al.  Stable Posterior Fusion of the Atlas and Axis by Transarticular Screw Fixation , 1987 .

[20]  J. Stevens,et al.  Transoral decompression and posterior fusion for rheumatoid atlanto-axial subluxation. , 1986, The Journal of bone and joint surgery. British volume.

[21]  C. Nelson,et al.  Total hip arthroplasty in Jehovah's Witnesses without blood transfusion. , 1986, The Journal of bone and joint surgery. American volume.

[22]  G. El-Khoury,et al.  Odontoid upward migration in rheumatoid arthritis. An analysis of 45 patients with "cranial settling". , 1985, Journal of neurosurgery.

[23]  A. Brooks,et al.  Atlanto-axial arthrodesis by the wedge compression method. , 1978, The Journal of bone and joint surgery. American volume.

[24]  G. B. Ong,et al.  Direct Anterior Approach to the Upper Cervical Spine , 1962 .

[25]  W. E Gallie,et al.  Fractures and dislocations of the cervical spine , 1939 .