Optimizing the response from a passively controlled biventricular assist device.

Recent studies into rotary biventricular support have indicated that inadequate left/right flow balancing may lead to vascular congestion and/or ventricular suckdown. The implementation of a passive controller that automatically adjusts left/right flow during total and partial cardiac support would improve physiological interaction. This has encouraged the development of a biventricular assist device (BiVAD) prototype that achieves passive control of the two rotary pumps' hydraulic output by way of a nonrotating double pressure plate configuration, the hub, suspended between the ventricular assist device (VAD) impellers. Fluctuations in either the VAD's inlet or outlet pressure will cause the hub to translate, and in doing so, affect each pump's hydraulic outputs. In order to achieve partial support, the floating assembly needed to respond to pathologic blood pressure signals while being insensitive to residual ventricular function. An incorporated mechanical spring-mass-damper assembly affects the passive response to optimize the dynamic interaction between the prototype and the supported cardiovascular system. It was found that increasing the damping from a medium to a high level was effective in filtering out the higher frequency ventricular pressure signals, reducing a modified amplitude ratio by up to 72%. A spring response was also identified as being inherent in the passive response and was characterized as being highly nonlinear at the extremes of the floating assembly's translation range. The results from this study introduce a new means of BiVAD control as well as the characterization of a fully passive mechanical physiological controller.

[1]  M B Visscher,et al.  The regulation of the energy output of the heart , 1927, The Journal of physiology.

[2]  Mikhail Skliar,et al.  Physiological control of blood pumps using intrinsic pump parameters: a computer simulation study. , 2006, Artificial organs.

[3]  T Sakamoto,et al.  Control strategy for rotary blood pumps. , 2001, Artificial organs.

[4]  K Araki,et al.  Sensorless controlling method for a continuous flow left ventricular assist device. , 2000, Artificial organs.

[5]  Andrew Galbraith,et al.  A complete mock circulation loop for the evaluation of left, right, and biventricular assist devices. , 2005, Artificial organs.

[6]  S. Takatani Progress of rotary blood pumps. , 2006, Artificial organs.

[7]  A. Guyton,et al.  Textbook of Medical Physiology , 1961 .

[8]  Bartley P Griffith,et al.  Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump. , 2006, Artificial organs.

[9]  Yukihiko Nosé,et al.  Current status of the gyro centrifugal blood pump--development of the permanently implantable centrifugal blood pump as a biventricular assist device (NEDO project). , 2004, Artificial organs.

[10]  Leok Poh Chua,et al.  Computational fluid dynamics of gap flow in a biocentrifugal blood pump. , 2005, Artificial organs.

[11]  Y Nosé,et al.  Development of the Baylor Gyro permanently implantable centrifugal blood pump as a biventricular assist device. , 2001, Artificial organs.

[12]  K Araki,et al.  The index of motor current amplitude has feasibility in control for continuous flow pumps and evaluation of left ventricular function. , 2001, Artificial organs.

[13]  John Fraser,et al.  The BiVACOR rotary biventricular assist device: concept and in vitro investigation. , 2008, Artificial organs.

[14]  Nicholas Richard Gaddum,et al.  A passively controlled biventricular support device. , 2010, Artificial organs.

[15]  K. Fukamachi,et al.  Acute In Vivo Evaluation of an Implantable Continuous Flow Biventricular Assist System , 2008, ASAIO journal.

[16]  J F Antaki,et al.  Computational fluid dynamics as a development tool for rotary blood pumps. , 2001, Artificial organs.

[17]  K Araki,et al.  Control strategy for biventricular assistance with mixed-flow pumps. , 2000, Artificial organs.

[18]  Y Miyazoe,et al.  Computational fluid dynamics analysis to establish the design process of a centrifugal blood pump: second report. , 1999, Artificial organs.