Contemporary x-ray wavelength metrology and traceability.

We report recent advances in absolute x-ray wavelength metrology in the context of producing modern standard reference data. Primary x-ray wavelength standards are produced today using diffraction spectrometers using crystal optics arranged to be operated in dispersive and non-dispersive geometries, giving natural-line-width limited profiles with high resolution and accuracy. With current developments, measurement results can be made traceable to the Système internationale definition of the meter by using diffraction crystals that have absolute lattice-spacing provenance through x-ray-optical interferometry. Recent advances in goniometry, innovation of electronic x-ray area detectors, and new in situ alignment and measurement methods now permit robust measurement and quantification of previously-elusive systematic uncertainties. This capability supports infrastructures like the NIST Standard Reference Data programs and the International Initiative on X-ray Fundamental Parameters and their contributions to science and industry. Such data projects are further served by employing complementary wavelength-and energy-dispersive spectroscopic techniques. This combination can provide, among other things, new tabulations of less-intense x-ray lines that need to be identified in x-ray fluorescence investigation of uncharacterized analytes. After delineating the traceability chain for primary x-ray wavelength standards, and NIST efforts to produce standard reference data and materials in particular, this paper posits the new opportunities for x-ray reference data tabulation that modern methods now afford.

[1]  J. Kimpton,et al.  Testing three-body quantum electrodynamics with trapped Ti20+ ions: evidence for a Z-dependent divergence between experiment and calculation. , 2012, Physical review letters.

[2]  Basile,et al.  Measurement of the silicon (220) lattice spacing. , 1994, Physical review letters.

[3]  Precision Comparison of the Lattice Parameters of Silicon Monocrystals , 1994 .

[4]  G. C. Hilton,et al.  Developments in Time-Division Multiplexing of X-ray Transition-Edge Sensors , 2016, Journal of low temperature physics.

[5]  B. Taylor,et al.  CODATA recommended values of the fundamental physical constants: 2006 | NIST , 2007, 0801.0028.

[6]  Naoki Kuramoto,et al.  Realization of the kilogram by the XRCD method , 2016 .

[7]  M. Mendenhall,et al.  High-precision measurement of the x-ray Cu Kα spectrum , 2016, Journal of physics. B, Atomic, molecular, and optical physics : an Institute of Physics journal.

[8]  G. Mana,et al.  A More Accurate Measurement of the 28Si Lattice Parameter , 2015 .

[9]  X-ray spectroscopy at next-generation inertial confinement fusion sources: Anticipating needs and challenges , 2006 .

[10]  Richard D. Deslattes,et al.  X-Ray to Visible Wavelength Ratios , 1973 .

[11]  E. Kessler,et al.  X-ray transition energies: new approach to a comprehensive evaluation , 2003 .

[12]  H. Siegert,et al.  Absolute Measurement of the (220) Lattice Plane Spacing in a Silicon Crystal , 1981 .

[13]  U. Bonse,et al.  AN X‐RAY INTERFEROMETER , 1965 .

[14]  G. C. Hilton,et al.  A reassessment of absolute energies of the x-ray L lines of lanthanide metals , 2017, 1702.00507.

[15]  M. Mendenhall,et al.  The Lattice Spacing Variability of Intrinsic Float-Zone Silicon. , 2017, Journal of research of the National Institute of Standards and Technology.

[16]  Lawrence T. Hudson,et al.  A simple method for high-precision calibration of long-range errors in an angle encoder using an electronic nulling autocollimator , 2015 .

[17]  E. Kessler,et al.  The GAMS4 flat crystal facility , 2001 .

[18]  T J Quinn,et al.  Practical realization of the definition of the metre, including recommended radiations of other optical frequency standards (2001) , 2003 .

[19]  M. Mendenhall,et al.  Characterization of a self-calibrating, high-precision, stacked-stage, vertical dual-axis goniometer , 2016, Metrologia.

[20]  Michael Hart,et al.  High precision lattice parameter measurements by multiple Bragg reflexion diffractometry , 1969, Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences.

[21]  Marcus H. Mendenhall,et al.  An algorithm for the compensation of short-period errors in optical encoders , 2015 .

[22]  K. Nakayama,et al.  Progress in the measurement of lattice spacing d(220) of silicon , 1997 .

[23]  J. Isac,et al.  A vacuum double-crystal spectrometer for reference-free X-ray spectroscopy of highly charged ions , 2014 .

[24]  C. T. Chantler,et al.  Absolute measurement of the resonance lines in heliumlike vanadium on an electron-beam ion trap , 2000 .

[25]  P Giacomo News from the BIPM , 1980 .

[26]  J. Seely,et al.  Laser-produced X-ray sources , 2010 .

[27]  P. Indelicato,et al.  Low-energy X-ray standards from hydrogenlike pionic atoms. , 2003, Physical review letters.

[28]  L T Hudson,et al.  A curved crystal spectrometer for energy calibration and spectral characterization of mammographic x-ray sources. , 1996, Medical physics.

[29]  P. Indelicato,et al.  Absolute measurements and simulations of x-ray line energies of highly charged ions with a double-crystal spectrometer , 2013 .