Simulation and optimization of load shedding scheme for islanded power system

The effect on system stability of load shedding has been a popular research topic for many years, especially in an islanded power system. But seldom studies gave full considerations to the actions of Primary Frequency Regulations (PFRs) and Overspeed Protection Control (OPC) systems of the generation units, which may have great impacts on the system responses against disturbances or emergency situations. When accidents occurred in the islanded power system, the power between generator units and load will be unbalanced. The rotating speed of steam turbine will clearly drop (rise) to a lower (higher) level. That may cause the action of load shedding control system (OPC of the generation units) to ensure the stability of the whole system. In this paper, a frequency response model incorporating an under-frequency load-shedding scheme is presented for islanded power system simulations and it is applied for a practical power system with both hydro and fossil fired power generators. Load shedding controls and OPCs are involved in the mathematic model. Some useful conclusions are obtained from the simulation results, based on which the mathematic model of the power system has been optimized in latter sections. Reasonable agreements are observed between the simulation results and the accident records. The simulation results also show that an optimized load shedding scheme may lead to better system stability which means the frequency oscillation will be reduced. When the PFR of hydropower isn't operated during the speed governing process, the frequency response of the whole system will be much better. It also suggests that if more electric power is generated by fossil fired turbine units, the system could get an advantageous frequency response.

[1]  B. Fox,et al.  Adaptive load shedding for isolated power systems , 1994 .

[2]  Naji A. Al-Musabi DESIGN OF OPTIMAL VARIABLE STRUCTURE CONTROLLERS: APPLICATIONS TO POWER SYSTEM DYNAMICS , 2004 .

[3]  Z.Y. Dong,et al.  Adaptive and optimal under frequency load shedding , 2008, 2008 Australasian Universities Power Engineering Conference.

[4]  Y. H. Song,et al.  Identification of a load-frequency characteristic for allocation of spinning reserves on the British electricity grid , 2006 .

[5]  J.R. Jones,et al.  Computer algorithm for selection of frequency relays for load shedding , 1988, IEEE Computer Applications in Power.

[6]  B. Wigdorowitz,et al.  A methodology for the redesign of frequency control for AC networks , 2004, IEEE Transactions on Power Systems.

[7]  Zhang Yiming Analysis on frequency response and primary frequency regulation of generato r units in Henan power system , 2002 .

[8]  Yiping Dai,et al.  Impact of Overspeed Protection Control on Stability for Islanded Power System , 2009 .

[9]  H. Seyedi,et al.  Design and simulation of an adaptive load shedding algorithm using a real network , 2006, 2006 IEEE Power India Conference.

[10]  Lin Gao,et al.  Analysis of power system frequency responses with hydro turbines incorporating load shedding , 2010, 2010 5th IEEE Conference on Industrial Electronics and Applications.

[11]  A. Saffarian,et al.  Performance Investigation of New Combinational Load Shedding Schemes , 2008, 2008 Joint International Conference on Power System Technology and IEEE Power India Conference.

[12]  Ieee Report,et al.  Dynamic Models for Steam and Hydro Turbines in Power System Studies , 1973 .

[13]  Luis Rouco,et al.  Representative Operating and Contingency Scenarios for the Design of UFLS Schemes , 2010, IEEE Transactions on Power Systems.

[14]  M. Sanaye-Pasand,et al.  Simulation and investigation of load shedding algorithms for a real network using dynamic modeling , 2004, 39th International Universities Power Engineering Conference, 2004. UPEC 2004..

[15]  Yung-Tien Chen,et al.  Study of applying load shedding scheme with dynamic D-factor values of various dynamic load models to Taiwan power system , 2005 .

[16]  S. Tesnjak,et al.  An adaptive approach to setting underfrequency load shedding relays for an isolated power system with private generation , 1998, MELECON '98. 9th Mediterranean Electrotechnical Conference. Proceedings (Cat. No.98CH36056).

[17]  P. Kundur,et al.  Impact of Turbine Generator Overspeed Controls on Unit Performance Under System Disturbance Conditions , 1985, IEEE Transactions on Power Apparatus and Systems.

[18]  U Rudez,et al.  Analysis of Underfrequency Load Shedding Using a Frequency Gradient , 2011, IEEE Transactions on Power Delivery.

[19]  P. M. Anderson,et al.  An adaptive method for setting underfrequency load shedding relays , 1992 .