Benefits of an increased prosthetic ankle range of motion for individuals with a trans-tibial amputation walking with a new prosthetic foot.

BACKGROUND Individuals with trans-tibial amputation show a greater peak prosthetic ankle power (push- off) when using energy storing and returning (ESAR) prosthetic feet as compared to solid-ankle cushion-heel feet. ESAR feet further contribute to the users' body support and thus limit prosthetic ankle motion. To improve ankle motion, articulating prosthetic feet have been introduced. However, articulating feet may diminish push-off. RESEARCH QUESTION Does a novel prosthetic foot, with a serial layout of carbon fibre leaf springs, connected by a multi-centre joint construction, have advantages in kinematics and kinetics over a conventional ESAR prosthetic foot?> METHODS: Eleven individuals with unilateral trans-tibial amputation were fitted with the novel foot (NF) and a conventional ESAR Foot (CF) and underwent 3D gait analysis. As an additional power estimate of the prosthetic ankle, a unified, deformable, segment model approach was applied. Eleven matched individuals without impairments served as a reference. RESULTS The NF shows an effective prosthetic ankle range of motion that is closer to a physiologic ankle range of motion, at 31.6° as compared to 15.2° with CF (CF vs. NF p = 0.003/NF vs. Reference p = 0.171) without reducing the maximum prosthetic ankle joint moment. Furthermore, the NF showed a great increase in prosthetic ankle power (NF 2.89 W/kg vs. CF 1.48 W/kg CF vs. NF p = <0.001) and a reduction of 19% in the peak knee varus moment and 13% in vertical ground reaction forces on the sound side for NF in comparison to CF. SIGNIFICANCE The NF shows that serial carbon fibre leaf springs, connected by a multi-centre joint construction gives a larger ankle joint range of motion and higher ankle power than a conventional carbon fibre structure alone. Consequently load is taken off the contralateral limb, as measured by the decrease in vertical ground reaction forces and peak knee varus moment.

[1]  J. Perry,et al.  The effect of five prosthetic feet on the gait and loading of the sound limb in dysvascular below-knee amputees. , 1995, Journal of rehabilitation research and development.

[2]  Johanne L Mattie,et al.  Biomechanical characteristics, patient preference and activity level with different prosthetic feet: a randomized double blind trial with laboratory and community testing. , 2015, Journal of biomechanics.

[3]  J. Czerniecki,et al.  BIOMECHANICAL ANALYSIS OF THE INFLUENCE OF PROSTHETIC FEET ON BELOW-KNEE AMPUTEE WALKING , 1991, American journal of physical medicine & rehabilitation.

[4]  W. Lee Childers,et al.  Increasing prosthetic foot energy return affects whole-body mechanics during walking on level ground and slopes , 2018, Scientific Reports.

[5]  Nerrolyn Ramstrand,et al.  Sagittal plane position of the functional joint centre of prosthetic foot/ankle mechanisms. , 2010, Clinical biomechanics.

[6]  T. Andriacchi,et al.  Knee adduction moment, serum hyaluronan level, and disease severity in medial tibiofemoral osteoarthritis. , 1998, Arthritis and rheumatism.

[7]  E D Lemaire,et al.  Osteoarthritis and elderly amputee gait. , 1994, Archives of physical medicine and rehabilitation.

[8]  R. B. Davis,et al.  A gait analysis data collection and reduction technique , 1991 .

[9]  S I Wolf,et al.  The Heidelberg foot measurement method: development, description and assessment. , 2006, Gait & posture.

[10]  Pradeep Suri,et al.  Osteoarthritis in the Disabled Population: A Mechanical Perspective , 2012, PM & R : the journal of injury, function, and rehabilitation.

[11]  Steven J Stanhope,et al.  A unified deformable (UD) segment model for quantifying total power of anatomical and prosthetic below-knee structures during stance in gait. , 2012, Journal of biomechanics.

[12]  J. Czerniecki,et al.  Joint moment and muscle power output characteristics of below knee amputees during running: the influence of energy storing prosthetic feet. , 1991, Journal of biomechanics.

[13]  Michael E. Hahn,et al.  The Potential for Error With Use of Inverse Dynamic Calculations in Gait Analysis of Individuals With Lower Limb Loss: A Review of Model Selection and Assumptions , 2010 .

[14]  Mark Edwards,et al.  Effects of prosthetic foot forefoot flexibility on gait of unilateral transtibial prosthesis users. , 2010, Journal of rehabilitation research and development.

[15]  D. Childress,et al.  The Effects of Prosthetic Foot Roll-Over Shape Arc Length on the Gait of Trans-Tibial Prosthesis Users , 2006, Prosthetics and orthotics international.

[16]  T. Andriacchi,et al.  Secondary gait changes in patients with medial compartment knee osteoarthritis: increased load at the ankle, knee, and hip during walking. , 2005, Arthritis and rheumatism.

[17]  Michael H Schwartz,et al.  The effect of walking speed on the gait of typically developing children. , 2008, Journal of biomechanics.

[18]  S. Gard,et al.  The human ankle during walking: implications for design of biomimetic ankle prostheses. , 2004, Journal of biomechanics.

[19]  D. Childress,et al.  The Effective Foot Length Ratio: A Potential Tool for Characterization and Evaluation of Prosthetic Feet , 2004 .

[20]  Alena M. Grabowski,et al.  Bionic ankle–foot prosthesis normalizes walking gait for persons with leg amputation , 2012, Proceedings of the Royal Society B: Biological Sciences.

[21]  T. Schmalz,et al.  [Significance of static prosthesis alignment for standing and walking of patients with lower limb amputation]. , 2001, Der Orthopade.

[22]  R. Gailey,et al.  Review of secondary physical conditions associated with lower-limb amputation and long-term prosthesis use. , 2008, Journal of rehabilitation research and development.

[23]  P. Adamczyk,et al.  Sensitivity of biomechanical outcomes to independent variations of hindfoot and forefoot stiffness in foot prostheses. , 2017, Human movement science.

[24]  E. Ayyappa,et al.  Influence of prosthetic foot design on sound limb loading in adults with unilateral below-knee amputations. , 1994, Archives of physical medicine and rehabilitation.

[25]  D. Winter,et al.  Biomechanics of below-knee amputee gait. , 1988, Journal of biomechanics.

[26]  H. K. Ramakrishnan,et al.  Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait , 1989, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[27]  Richard R Neptune,et al.  Muscle and prosthesis contributions to amputee walking mechanics: a modeling study. , 2012, Journal of biomechanics.

[28]  Alan R De Asha,et al.  Impact on the biomechanics of overground gait of using an 'Echelon' hydraulic ankle-foot device in unilateral trans-tibial and trans-femoral amputees. , 2014, Clinical biomechanics.

[29]  Michael E Hahn,et al.  Trajectory of the center of rotation in non-articulated energy storage and return prosthetic feet. , 2011, Journal of biomechanics.

[30]  J. Perry,et al.  Gait Analysis , 2024 .

[31]  S I Wolf,et al.  Electromyographic patterns in children with cerebral palsy: do they change after surgery? , 2007, Gait & posture.

[32]  A H Hansen,et al.  Prosthetic foot rollover shapes with implications for alignment of transtibial prostheses , 2000, Prosthetics and orthotics international.

[33]  S. Collins,et al.  The effect of prosthetic foot push-off on mechanical loading associated with knee osteoarthritis in lower extremity amputees. , 2011, Gait & posture.

[34]  Nicholas P. Fey,et al.  The influence of energy storage and return foot stiffness on walking mechanics and muscle activity in below-knee amputees. , 2011, Clinical biomechanics.

[35]  M. Nash,et al.  The amputee mobility predictor: an instrument to assess determinants of the lower-limb amputee's ability to ambulate. , 2002, Archives of physical medicine and rehabilitation.

[36]  D. Winter Energy generation and absorption at the ankle and knee during fast, natural, and slow cadences. , 1983, Clinical orthopaedics and related research.

[37]  Glen D. Rayner,et al.  Robustness to non-normality of common tests for the many-sample location problem , 2003, Adv. Decis. Sci..

[38]  Jai Kulkarni,et al.  Association between amputation, arthritis and osteopenia in British male war veterans with major lower limb amputations , 1998 .

[39]  C Kirtley,et al.  Influence of walking speed on gait parameters. , 1985, Journal of biomedical engineering.