Principal Component Analysis Based Dynamic Cone Beam X-Ray Luminescence Computed Tomography: A Feasibility Study

Cone beam X-ray luminescence computed tomography (CB-XLCT) is a promising imaging technique in studying the physiological and pathological processes in small animals. However, the dynamic bio-distributions of probes in small animal, especially in adjacent targets are still hard to be captured directly from dynamic CB-XLCT. In this paper, a 4D temporal-spatial reconstruction method based on principal component analysis (PCA) in the projection space is proposed for dynamic CB-XLCT. First, projections of angles in each 3D frame are compressed to reduce the noises initially. Then a temporal PCA is performed on the projection data to decorrelate the 4D problem into separate 3D problems in the PCA domain. In the PCA domain, the difference between dynamic behaviors of multiple targets can be reflected by the first several principal components which can be further used for fast and improved reconstruction by a restarted Tikhonov regularization method. At last, by discarding the principal components mainly reflecting noise, the concentration series of targets are recovered from the first few reconstruction results with a mask as the constraint. The numerical simulation and phantom experiment demonstrate that the proposed method can resolve multiple targets and recover the dynamic distributions with high computation efficiency. The proposed method provides new feasibility for imaging dynamic bio-distributions of probes in vivo.

[1]  H. Abdi,et al.  Principal component analysis , 2010 .

[2]  Julien Bec,et al.  X-ray luminescence optical tomography imaging: experimental studies. , 2013, Optics letters.

[3]  Jie Tian,et al.  Cone beam x-ray luminescence computed tomography: a feasibility study. , 2013, Medical physics.

[4]  Jie Tian,et al.  In vivo quantitative bioluminescence tomography using heterogeneous and homogeneous mouse models. , 2010, Optics express.

[5]  Dianne P. O'Leary,et al.  The Use of the L-Curve in the Regularization of Discrete Ill-Posed Problems , 1993, SIAM J. Sci. Comput..

[6]  Jianwen Luo,et al.  Separating structures of different fluorophore concentrations by principal component analysis on multispectral excitation-resolved fluorescence tomography images. , 2013, Biomedical optics express.

[7]  Kevin Welsher,et al.  Deep-tissue anatomical imaging of mice using carbon nanotube fluorophores in the second near-infrared window , 2011, Proceedings of the National Academy of Sciences.

[8]  L Xing,et al.  Limited-angle x-ray luminescence tomography: methodology and feasibility study , 2011, Physics in medicine and biology.

[9]  A. Kienle,et al.  Optical properties of fat emulsions. , 2008, Optics express.

[10]  Vasilis Ntziachristos,et al.  Looking and listening to light: the evolution of whole-body photonic imaging , 2005, Nature Biotechnology.

[11]  Jianwen Luo,et al.  Full-direct method for imaging pharmacokinetic parameters in dynamic fluorescence molecular tomography , 2015 .

[12]  Lei Xing,et al.  Synthesis and Radioluminescence of PEGylated Eu3+‐doped Nanophosphors as Bioimaging Probes , 2011, Advanced materials.

[13]  A. Butler,et al.  Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE , 2010, European Radiology.

[14]  J. Bai,et al.  Principal component analysis of dynamic fluorescence diffuse optical tomography images. , 2010, Optics express.

[15]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[16]  Hongkai Zhao,et al.  Robust principal component analysis-based four-dimensional computed tomography , 2011, Physics in medicine and biology.

[17]  F. Pedersen,et al.  Principal component analysis of dynamic positron emission tomography images , 1994, European Journal of Nuclear Medicine.

[18]  M. Schweiger,et al.  Three-dimensional in vivo fluorescence diffuse optical tomography of breast cancer in humans. , 2007, Optics express.

[19]  M. Schweiger,et al.  The finite element method for the propagation of light in scattering media: boundary and source conditions. , 1995, Medical physics.

[20]  Ian M. Kennedy,et al.  NaGdF4:Eu3+ Nanoparticles for Enhanced X-ray Excited Optical Imaging , 2014, Chemistry of materials : a publication of the American Chemical Society.

[21]  Qimei Liao,et al.  Excitation-resolved cone-beam x-ray luminescence tomography. , 2015, Journal of biomedical optics.

[22]  E. Hoffman,et al.  In vivo mouse studies with bioluminescence tomography. , 2006, Optics express.

[23]  Shouping Zhu,et al.  Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging , 2014 .

[24]  Qimei Liao,et al.  In vivo x-ray luminescence tomographic imaging with single-view data. , 2013, Optics letters.

[25]  Xiaogang Qu,et al.  Long-circulating Er3+-doped Yb2O3 up-conversion nanoparticle as an in vivo X-Ray CT imaging contrast agent. , 2012, Biomaterials.

[26]  Xin Wang,et al.  An adaptive Tikhonov regularization method for fluorescence molecular tomography , 2013, Medical & Biological Engineering & Computing.

[27]  John C. Gore,et al.  Monitoring pH-triggered drug release from radioluminescent nanocapsules with X-ray excited optical luminescence. , 2013, ACS nano.

[28]  Junyan Rong,et al.  Resolving adjacent nanophosphors of different concentrations by excitation-based cone-beam X-ray luminescence tomography. , 2017, Biomedical optics express.

[29]  W. Lu,et al.  PEGylated NaLuF4: Yb/Er upconversion nanophosphors for in vivo synergistic fluorescence/X-ray bioimaging and long-lasting, real-time tracking. , 2014, Biomaterials.

[30]  Lei Xing,et al.  X-Ray Luminescence Computed Tomography via Selective Excitation: A Feasibility Study , 2010, IEEE Transactions on Medical Imaging.

[31]  L. R. Dice Measures of the Amount of Ecologic Association Between Species , 1945 .

[32]  E. Hillman,et al.  All-optical anatomical co-registration for molecular imaging of small animals using dynamic contrast. , 2007, Nature photonics.

[33]  Qimei Liao,et al.  Fast X-Ray Luminescence Computed Tomography Imaging , 2014, IEEE Transactions on Biomedical Engineering.

[34]  Xin Liu,et al.  Unmixing Dynamic Fluorescence Diffuse Optical Tomography Images With Independent Component Analysis , 2011, IEEE Transactions on Medical Imaging.

[35]  J. Culver,et al.  Time-dependent whole-body fluorescence tomography of probe bio-distributions in mice. , 2005, Optics express.

[36]  Li Zhang,et al.  Feature constrained compressed sensing CT image reconstruction from incomplete data via robust principal component analysis of the database , 2013, Physics in medicine and biology.

[37]  Lei Xing,et al.  X-ray-Induced Shortwave Infrared Biomedical Imaging Using Rare-Earth Nanoprobes , 2014, Nano letters.

[38]  A. Chatziioannou,et al.  Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility study , 2005, Physics in medicine and biology.

[39]  R. Leahy,et al.  Digimouse: a 3D whole body mouse atlas from CT and cryosection data , 2007, Physics in medicine and biology.

[40]  M. Murphy,et al.  4D Cone-beam CT reconstruction using a motion model based on principal component analysis. , 2011, Medical physics.

[41]  B. Nicolas Bloch,et al.  Principal Component Analysis of Dynamic Contrast Enhanced MRI in Human Prostate Cancer , 2010, Investigative radiology.

[42]  Gene H. Golub,et al.  Numerical methods for solving linear least squares problems , 1965, Milestones in Matrix Computation.

[43]  Lei Xing,et al.  Tomographic molecular imaging of x-ray-excitable nanoparticles. , 2010, Optics letters.

[44]  Jiang Du,et al.  Noise reduction in multiple-echo data sets using singular value decomposition. , 2006, Magnetic resonance imaging.

[45]  Huijuan Zhao,et al.  Three-dimensional scheme for time-domain fluorescence molecular tomography based on Laplace transforms with noise-robust factors. , 2008, Optics express.

[46]  Junyan Rong,et al.  Spectral-resolved cone-beam X-ray luminescence computed tomography with principle component analysis. , 2018, Biomedical optics express.

[47]  Pasha Razifar,et al.  Principal component analysis with pre-normalization improves the signal-to-noise ratio and image quality in positron emission tomography studies of amyloid deposits in Alzheimer's disease. , 2009, Physics in medicine and biology.

[48]  R. Leahy,et al.  A three-dimensional multispectral fluorescence optical tomography imaging system for small animals based on a conical mirror design. , 2009, Optics express.