2-D CMUT wafer bonded imaging arrays with a row-column addressing scheme

This paper presents fabrication and characterization results of two-dimensional capacitive micromachined ultrasonic transducer arrays which use a row-column addressing scheme. The devices are fabricated using a wafer bonding process where both the insulation layer and the membrane are user deposited silicon nitride. Two types of arrays with different resonant frequencies are presented. One is a 32×32 element array which has a resonant frequency of 15 MHz. In immersion, when transmitting and receiving with columns a centre frequency of 5.45 MHz is measured with a relative -6 dB bandwidth of 119%. Using rows, a centre frequency of 5.75 MHz is measured with a −6 dB bandwidth of 135%. The other device is a 32×32 element array with a resonant frequency of 28 MHz and in immersion has a centre frequency of ∼12 MHz. Membrane resonant frequency uniformity across the 15 MHz device has a measured standard deviation of 0.3%.

[1]  Chi Hyung Seo,et al.  A 256 x 256 2-D array transducer with row-column addressing for 3-D rectilinear imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  O. Oralkan,et al.  Wafer-bonded 2-D CMUT arrays incorporating through-wafer trench-isolated interconnects with a supporting frame , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  J. Yeow,et al.  1-D CMUT arrays fabricated using a novel wafer bonding process , 2008, 2008 IEEE Ultrasonics Symposium.

[4]  J. Yeow,et al.  Fabricating capacitive micromachined ultrasonic transducers with a novel silicon-nitride-Based wafer bonding process , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  Edward Hæggström,et al.  Fabricating capacitive micromachined ultrasonic transducers with wafer-bonding technology , 2003 .

[6]  A. Ronnekleiv,et al.  Fabrication and Characterization of CMUTs realized by Wafer Bonding , 2006, 2006 IEEE Ultrasonics Symposium.

[7]  Butrus T. Khuri-Yakub,et al.  Minimally Redundant 2-D Array Designs for 3-D Medical Ultrasound Imaging , 2009, IEEE Transactions on Medical Imaging.

[8]  O. Oralkan,et al.  Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  C. Daft,et al.  5G-1 Two Approaches to Electronically Scanned 3D Imaging Using cMUTs , 2006, 2006 IEEE Ultrasonics Symposium.

[10]  B. Khuri-Yakub,et al.  Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging? , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  I. Ladabaum,et al.  Microfabricated ultrasonic transducers monolithically integrated with high voltage electronics , 2004, IEEE Ultrasonics Symposium, 2004.

[12]  G. Gurun,et al.  Single chip CMUT arrays with integrated CMOS electronics: Fabrication process development and experimental results , 2008, 2008 IEEE Ultrasonics Symposium.