New system for neonatal hearing screening based on auditory steady state responses

Abstract NEURONIC-A 6.0 is a system for objective detection of hearing loss by means of the recording and analysis of auditory steady state responses. The system generates digitally Amplitude Modulated tones of different frequencies, allowing the mix of these and the simultaneous presentation through different transducers (earphone and bone vibrator) at different intensities. The system also includes a procedure for artefacts rejection based on the trajectory of variation of the residual noise through time and quantitative indicators or statistics, calculated in the frequency domain, to control the acquisition of the response process and detect automatically the presence or absence of the same. The whole working procedure is automated, which means that once the recording has started, a final result can be obtained in binary form (pass or fail) without the intervention of the examiner.

[1]  D. Kemp Stimulated acoustic emissions from within the human auditory system. , 1978, The Journal of the Acoustical Society of America.

[2]  Jacobson Jt,et al.  Automated and conventional ABR screening techniques in high-risk infants. , 1990 .

[3]  J. Jacobson,et al.  Automated and conventional ABR screening techniques in high-risk infants. , 1990, Journal of the American Academy of Audiology.

[4]  T W Picton,et al.  Auditory steady-state responses to tones amplitude-modulated at 80-110 Hz. , 1995, The Journal of the Acoustical Society of America.

[5]  Yvonne Sininger,et al.  Identification of Neonatal Hearing Impairment: Evaluation of Transient Evoked Otoacoustic Emission, Distortion Product Otoacoustic Emission, and Auditory Brain Stem Response Test Performance , 2000, Ear and hearing.

[6]  T Fuse,et al.  An application of phase spectral analysis to amplitude-modulation following response. , 1993, Acta oto-laryngologica. Supplementum.

[7]  Susan A Small,et al.  Multiple auditory steady-state response thresholds to bone-conduction stimuli in young infants with normal hearing. , 2005, Ear and hearing.

[8]  Lei Gao,et al.  Auditory neuropathy. , 2015, Handbook of clinical neurology.

[9]  R A Dobie,et al.  Objective Response Detection , 1993, Ear and hearing.

[10]  N. Galloway Human Brain Electrophysiology: Evoked Potentials and Evoked Magnetic Fields in Science and Medicine , 1990 .

[11]  Terence W Picton,et al.  Advantages and caveats when recording steady-state responses to multiple simultaneous stimuli. , 2002, Journal of the American Academy of Audiology.

[12]  Kileny Pr New insights on infant ABR hearing screening. , 1988 .

[13]  O. Lins,et al.  Comparison of Statistical Indicators for the Automatic Detection of 80 Hz Auditory Steady State Responses , 1997, Ear and hearing.

[14]  Jan Wouters,et al.  Clinical Application of Dichotic Multiple-Stimulus Auditory Steady-State Responses in High-Risk Newborns and Young Children , 2006, Audiology and Neurotology.

[15]  R A Dobie,et al.  Objective response detection in the frequency domain. , 1993, Electroencephalography and clinical neurophysiology.

[16]  G. Cascino,et al.  Subcortical Dementia , 1991, Neurology.

[17]  P. Kileny New insights on infant ABR hearing screening. , 1988, Scandinavian audiology. Supplementum.

[18]  E. Poole,et al.  Current practice of clinical electroencephalography D. W. Klass &D. D. Daly, Raven Press, 1979, 544 pp. $61.20 , 1980, Neuroscience.

[19]  J. Victor,et al.  A new statistic for steady-state evoked potentials. , 1991, Electroencephalography and clinical neurophysiology.

[20]  R A Dobie,et al.  Analysis of auditory evoked potentials by magnitude-squared coherence. , 1989, Ear and hearing.

[21]  L. Galán,et al.  Steady State Responses to Multiple Amplitude-Modulated Tones: An Optimized Method to Test Frequency-Specific Thresholds in Hearing-Impaired Children and Normal-Hearing Subjects , 2001, Ear and hearing.

[22]  G. S. López,et al.  Potenciales evocados auditivos de estado estable en el estudio de dos pacientes con neuropatía auditiva , 2005 .

[23]  T. Picton,et al.  Prognostic validity of brainstem electric response audiometry in infants of a neonatal intensive care unit. , 1991, Audiology : official organ of the International Society of Audiology.

[24]  G. Savio,et al.  The Low and High Frequency Auditory Steady State Responses Mature at Different Rates , 2001, Audiology and Neurotology.

[25]  A. Cacace,et al.  New York State Universal Newborn Hearing Screening Demonstration Project: Effects of Screening Protocol on Inpatient Outcome Measures , 2000, Ear and hearing.

[26]  M. Feinmesser,et al.  XXXIV Cochlear Action Potentials Recorded from the External Ear in Man , 1967, The Annals of otology, rhinology, and laryngology.