A Preliminary Assessment of Legged Mobility Provided by a Lower Limb Exoskeleton for Persons With Paraplegia

This paper presents an assessment of a lower limb exoskeleton for providing legged mobility to people with paraplegia. In particular, the paper presents a single-subject case study comparing legged locomotion using the exoskeleton to locomotion using knee-ankle-foot orthoses (KAFOs) on a subject with a T10 motor and sensory complete injury. The assessment utilizes three assessment instruments to characterize legged mobility, which are the timed up-and-go test, the Ten-Meter Walk Test (10 MWT), and the Six-Minute Walk Test (6 MWT), which collectively assess the subject's ability to stand, walk, turn, and sit. The exertion associated with each assessment instrument was assessed using the Physiological Cost Index. Results indicate that the subject was able to perform the respective assessment instruments 25%, 70%, and 80% faster with the exoskeleton relative to the KAFOs for the timed up-and-go test, the 10 MWT, and the 6 MWT, respectively. Measurements of exertion indicate that the exoskeleton requires 1.6, 5.2, and 3.2 times less exertion than the KAFOs for each respective assessment instrument. The results indicate that the enhancement in speed and reduction in exertion are more significant during walking than during gait transitions.

[1]  R. Brissot,et al.  Clinical experience with functional electrical stimulation-assisted gait with Parastep in spinal cord-injured patients. , 2000, Spine.

[2]  Volker Dietz,et al.  Assessing walking ability in subjects with spinal cord injury: validity and reliability of 3 walking tests. , 2005, Archives of physical medicine and rehabilitation.

[3]  G M Davis,et al.  Energy expenditure during gait using the walkabout and isocentric reciprocal gait orthoses in persons with paraplegia. , 1998, Archives of physical medicine and rehabilitation.

[4]  Scott Tashman,et al.  Development of hybrid orthosis for standing, walking, and stair climbing after spinal cord injury. , 2009, Journal of rehabilitation research and development.

[5]  M. Morris,et al.  Reliability of measurements obtained with the Timed "Up & Go" test in people with Parkinson disease. , 2001, Physical therapy.

[6]  M. Woollacott,et al.  Predicting the probability for falls in community-dwelling older adults using the Timed Up & Go Test. , 2000, Physical therapy.

[7]  A V Nene,et al.  Physiological cost index of paraplegic locomotion using the ORLAU ParaWalker , 1992, Paraplegia.

[8]  William K Durfee,et al.  Design and simulation of a pneumatic, stored-energy, hybrid orthosis for gait restoration. , 2005, Journal of biomechanical engineering.

[9]  J Mizrahi,et al.  Activation of paraplegic patients by functional electrical stimulation: training and biomechanical evaluation. , 1985, Scandinavian journal of rehabilitation medicine. Supplement.

[10]  A. Yohannes,et al.  Respiratory rehabilitation, exercise capacity and quality of life in chronic airways disease in old age. , 1996, Age and ageing.

[11]  Yasuhisa Hasegawa,et al.  Standing-up motion support for paraplegic patient with Robot Suit HAL , 2009, 2009 IEEE International Conference on Rehabilitation Robotics.

[12]  M. Goldfarb,et al.  Preliminary evaluation of a controlled-brake orthosis for FES-aided gait , 2003, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[13]  Hugo A. Quintero,et al.  A Powered Lower Limb Orthosis for Providing Legged Mobility in Paraplegic Individuals. , 2011, Topics in spinal cord injury rehabilitation.

[14]  Eben Alexander Spinal cord injury. A guide for patient and family , 1988 .

[15]  K. Klose,et al.  Evaluation of a training program for persons with SCI paraplegia using the Parastep 1 ambulation system: part 1. Ambulation performance and anthropometric measures. , 1997, Archives of physical medicine and rehabilitation.

[16]  G. Baer,et al.  Achievement of simple mobility milestones after stroke. , 1999, Archives of physical medicine and rehabilitation.

[17]  J. Chandler,et al.  Reliability of impairment and physical performance measures for persons with Parkinson's disease. , 1997, Physical therapy.

[18]  D. Graupe,et al.  Quantitative weightbearing and gait evaluation of paraplegics using functional electrical stimulation , 2006, Medical and Biological Engineering and Computing.

[19]  Yasuhisa Hasegawa,et al.  Intention-based walking support for paraplegia patients with Robot Suit HAL , 2007, Adv. Robotics.

[20]  E. Isakov,et al.  Biomechanical and physiological evaluation of FES-activated paraplegic patients. , 1986, Journal of rehabilitation research and development.

[21]  A. Esquenazi,et al.  The ReWalk Powered Exoskeleton to Restore Ambulatory Function to Individuals with Thoracic-Level Motor-Complete Spinal Cord Injury , 2012, American journal of physical medicine & rehabilitation.

[22]  Janice J Eng,et al.  Functional Walk Tests in Individuals With Stroke: Relation to Perceived Exertion and Myocardial Exertion , 2002, Stroke.

[23]  A. Stewart,et al.  Mobility-related function in older adults: assessment with a 6-minute walk test. , 1999, Archives of physical medicine and rehabilitation.

[24]  E. Knutsson,et al.  Dynamic motor capacity in spastic paresis and its relation to prime mover dysfunction, spastic reflexes and antagonist co-activation. , 1980, Scandinavian journal of rehabilitation medicine.

[25]  Homayoon Kazerooni,et al.  The development and testing of a human machine interface for a mobile medical exoskeleton , 2011, 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[26]  Yasuhisa Hasegawa,et al.  Cooperative walk control of paraplegia patient and assistive system , 2009, 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[27]  Jerry E Pratt,et al.  Design and evaluation of Mina: A robotic orthosis for paraplegics , 2011, 2011 IEEE International Conference on Rehabilitation Robotics.

[28]  V. Dietz,et al.  Standardized assessment of walking capacity after spinal cord injury: the European network approach , 2008, Neurological research.

[29]  P. Winchester,et al.  Physiologic costs of reciprocal gait in FES assisted walking , 1994, Paraplegia.

[30]  A. Jaiyesimi,et al.  Reliability of physiological cost index measurements. , 2007, African journal of medicine and medical sciences.

[31]  Michael Goldfarb,et al.  A Method for the Autonomous Control of Lower Limb Exo-skeletons for Persons with Paraplegia. , 2012, Journal of medical devices.

[32]  A. Esquenazi,et al.  Safety and tolerance of the ReWalk™ exoskeleton suit for ambulation by people with complete spinal cord injury: A pilot study , 2012, The journal of spinal cord medicine.

[33]  M. Thompson,et al.  Performance of Individuals with Parkinsonʼs Disease on the Timed Up & Go , 1998 .

[34]  R. Triolo,et al.  Consumer perspectives on mobility: implications for neuroprosthesis design. , 2002, Journal of rehabilitation research and development.

[35]  Diane Podsiadlo,et al.  The Timed “Up & Go”: A Test of Basic Functional Mobility for Frail Elderly Persons , 1991, Journal of the American Geriatrics Society.

[36]  M. Granat,et al.  A new method of using heart rate to represent energy expenditure: the Total Heart Beat Index. , 2002, Archives of physical medicine and rehabilitation.

[37]  J. MacGREGOR,et al.  The objective measurement of physical performance with long term ambulatory physiological surveillance equipment , 1979 .

[38]  Jerry E. Pratt,et al.  Development of the IHMC Mobility Assist Exoskeleton , 2009, 2009 IEEE International Conference on Robotics and Automation.

[39]  A. Nene,et al.  Physiological cost index of walking in able-bodied adolescents and adults , 1993 .

[40]  W H Eisma,et al.  The Timed "up and go" test: reliability and validity in persons with unilateral lower limb amputation. , 1999, Archives of physical medicine and rehabilitation.

[41]  R. Kobetic,et al.  Design of a Variable Constraint Hip Mechanism for a Hybrid Neuroprosthesis to Restore Gait After Spinal Cord Injury , 2008, IEEE/ASME Transactions on Mechatronics.

[42]  R. Kobetic,et al.  Gait Evaluation of a Novel Hip Constraint Orthosis With Implication for Walking in Paraplegia , 2010, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[43]  J J Eng,et al.  A systematic review of functional ambulation outcome measures in spinal cord injury , 2008, Spinal Cord.

[44]  D. Wade,et al.  Validity and reliability comparison of 4 mobility measures in patients presenting with neurologic impairment. , 2001, Archives of physical medicine and rehabilitation.

[45]  Maggie J Bailey,et al.  Reliability of Physiological Cost Index Measurements in Walking Normal Subjects Using Steady-state, Non-steady-state and Post-exercise Heart Rate Recording , 1995 .

[46]  K. Nakazawa,et al.  A two-degree-of-freedom motor-powered gait orthosis for spinal cord injury patients , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[47]  Yasuhisa Hasegawa,et al.  Sit-to-Stand and Stand-to-Sit Transfer Support for Complete Paraplegic Patients with Robot Suit HAL , 2010, Adv. Robotics.