Accurate Localization of Optic Radiation During Neurosurgery in an Interventional MRI Suite

Accurate localization of the optic radiation is key to improving the surgical outcome for patients undergoing anterior temporal lobe resection for the treatment of refractory focal epilepsy. Current commercial interventional magnetic resonance imaging (MRI) scanners are capable of performing anatomical and diffusion weighted imaging and are used for guidance during various neurosurgical procedures. We present an interventional imaging workflow that can accurately localize the optic radiation during surgery. The workflow is driven by a near real-time multichannel nonrigid image registration algorithm that uses both anatomical and fractional anisotropy pre- and intra-operative images. The proposed workflow is implemented on graphical processing units and we perform a warping of the pre-operatively parcellated optic radiation to the intra-operative space in under 3 min making the proposed algorithm suitable for use under the stringent time constraints of neurosurgical procedures. The method was validated using both a numerical phantom and clinical data using pre- and post-operative images from patients who had undergone surgery for treatment of refractory focal epilepsy and shows strong correlation between the observed post-operative visual field deficit and the predicted damage to the optic radiation. We also validate the algorithm using interventional MRI datasets from a small cohort of patients. This work could be of significant utility in image guided interventions and facilitate effective surgical treatments.

[1]  Daniel C. Alexander,et al.  Camino: Open-Source Diffusion-MRI Reconstruction and Processing , 2006 .

[2]  Mark W. Woolrich,et al.  Probabilistic diffusion tractography with multiple fibre orientations: What can we gain? , 2007, NeuroImage.

[3]  David R. Haynor,et al.  PET-CT image registration in the chest using free-form deformations , 2003, IEEE Transactions on Medical Imaging.

[4]  A. Alexander,et al.  Does fractional anisotropy have better noise immunity characteristics than relative anisotropy in diffusion tensor MRI? An analytical approach , 2004, Magnetic resonance in medicine.

[5]  W T Blume,et al.  A randomized, controlled trial of surgery for temporal-lobe epilepsy. , 2001, The New England journal of medicine.

[6]  Paul A. Viola,et al.  Alignment by Maximization of Mutual Information , 1997, International Journal of Computer Vision.

[7]  Yang Li,et al.  Multichannel Image Registration by Feature-Based Information Fusion , 2011, IEEE Transactions on Medical Imaging.

[8]  W. Hall,et al.  Brain tumor resection: intraoperative monitoring with high-field-strength MR imaging-initial results. , 2000, Radiology.

[9]  Sang Joon Kim,et al.  A Mathematical Theory of Communication , 2006 .

[10]  R. Kikinis,et al.  Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications. , 1997, Neurosurgery.

[11]  C. Nimsky,et al.  Intraoperative compensation for brain shift. , 2001, Surgical neurology.

[12]  R. Parrish,et al.  Static and kinetic visual field testing. Reproducibility in normal volunteers. , 1984, Archives of ophthalmology.

[13]  Daniel Rueckert,et al.  Nonrigid registration using free-form deformations: application to breast MR images , 1999, IEEE Transactions on Medical Imaging.

[14]  Sébastien Ourselin,et al.  Improved Neuronavigation through Integration of Intraoperative Anatomical and Diffusion Images in an Interventional MRI Suite , 2011, IPCAI.

[15]  N. Hata,et al.  Serial Intraoperative Magnetic Resonance Imaging of Brain Shift , 2001, Neurosurgery.

[16]  N. K. Focke,et al.  Defining Meyer's loop–temporal lobe resections, visual field deficits and diffusion tensor tractography , 2009, Brain : a journal of neurology.

[17]  Sébastien Ourselin,et al.  Integrating structural and diffusion MR information for optic radiation localisation in focal epilepsy patients , 2011, 2011 IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[18]  Derek K. Jones,et al.  Estimating the number of fiber orientations in diffusion MRI voxels : a constrained spherical deconvolution study , 2010 .

[19]  Rüdiger Westermann,et al.  A survey of medical image registration on graphics hardware , 2011, Comput. Methods Programs Biomed..

[20]  U. Ebeling,et al.  Neurosurgical topography of the optic radiation in the temporal lobe , 2005, Acta Neurochirurgica.

[21]  Sébastien Ourselin,et al.  Fast free-form deformation using graphics processing units , 2010, Comput. Methods Programs Biomed..

[22]  Stephen M Smith,et al.  Fast robust automated brain extraction , 2002, Human brain mapping.

[23]  Carl-Fredrik Westin,et al.  Spatial normalization of diffusion tensor MRI using multiple channels , 2003, NeuroImage.

[24]  M E Bastin,et al.  Selecting an appropriate anisotropy index for displaying diffusion tensor imaging data with improved contrast and sensitivity , 2000, Magnetic resonance in medicine.

[25]  Colin Studholme,et al.  An overlap invariant entropy measure of 3D medical image alignment , 1999, Pattern Recognit..

[26]  Marc Modat,et al.  Optic Radiation Tractography and Vision in Anterior Temporal Lobe Resection , 2012, Annals of neurology.

[27]  William Kahan,et al.  Pracniques: further remarks on reducing truncation errors , 1965, CACM.

[28]  Brian B. Avants,et al.  Multivariate Normalization with Symmetric Diffeomorphisms for Multivariate Studies , 2007, MICCAI.

[29]  Michael Unser,et al.  Optimization of mutual information for multiresolution image registration , 2000, IEEE Trans. Image Process..

[30]  Benoit M. Dawant,et al.  Semiautomatic Registration of Pre- and Postbrain Tumor Resection Laser Range Data: Method and Validation , 2009, IEEE Transactions on Biomedical Engineering.

[31]  Olivier Clatz,et al.  Non-rigid alignment of pre-operative MRI, fMRI, and DT-MRI with intra-operative MRI for enhanced visualization and navigation in image-guided neurosurgery , 2007, NeuroImage.

[32]  R Kikinis,et al.  Intraoperative diffusion imaging on a 0.5 Tesla interventional scanner , 2001, Journal of magnetic resonance imaging : JMRI.

[33]  Walter A Hall,et al.  Intraoperative MR imaging. , 2005, Magnetic resonance imaging clinics of North America.

[34]  Colin Studholme,et al.  Dense feature deformation morphometry: Incorporating DTI data into conventional MRI morphometry , 2008, Medical Image Anal..

[35]  Gareth J. Barker,et al.  From diffusion tractography to quantitative white matter tract measures: a reproducibility study , 2003, NeuroImage.