Efficiency and Reliability Analyses of AC and 380 V DC Distribution in Data Centers

Modern data centers consume large amounts of electricity, resulting in high operational costs. The efficiency of a data center power distribution system can be increased and the operational cost reduced if the number of power conversion stages can be minimized and more efficient converters, such as wide bandgap converters, are used. This can be achieved by using dc distribution voltage at the rack level by eliminating extra conversion stages. In this paper, benchmarks for both ac and 380-V dc data centers were developed and efficiency analyses were performed for an entire year. The impact of integrating photovoltaic (PV) systems into the data centers has also been analyzed in both cases in terms of efficiency. The results show that 380-V dc data centers are more efficient than ac data centers with and without PV integration. Furthermore, the reliability of an ac system was compared with a 380-V dc architecture with Tier-IV standard. Monte-Carlo simulations were used to perform reliability analyses for different levels of redundancy in the uninterruptible power supply system for both cases. The simulation results showed that the 380-V dc distribution system had a higher level of reliability than the ac distribution system in data centers.

[1]  Angelika Bayer,et al.  Solar Engineering Of Thermal Processes , 2016 .

[2]  Leon M. Tolbert,et al.  Wide bandgap power devices based high efficiency power converters for data center application , 2014, 2014 IEEE Workshop on Wide Bandgap Power Devices and Applications.

[3]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[4]  Timothy M. Hansen,et al.  Reliability analysis of 380V DC distribution in data centers , 2016, 2016 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT).

[5]  Thu D. Nguyen,et al.  Parasol and GreenSwitch: managing datacenters powered by renewable energy , 2013, ASPLOS '13.

[6]  Fang Liu,et al.  Voltage Stability Analysis and Sliding-Mode Control Method for Rectifier in DC Systems With Constant Power Loads , 2017, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[7]  R. Messenger,et al.  Photovoltaic Systems Engineering , 2018 .

[8]  Ben Guo,et al.  Design and performance of an all-SiC three-phase buck rectifier for high efficiency data center power supplies , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[9]  Praveen Jain,et al.  Beyond the curves: Modeling the electrical efficiency of photovoltaic inverters , 2008, 2008 33rd IEEE Photovoltaic Specialists Conference.

[10]  Canbing Li,et al.  Flexible Voltage Control Strategy Considering Distributed Energy Storages for DC Distribution Network , 2019, IEEE Transactions on Smart Grid.

[11]  Min Xie,et al.  Reliability analysis using an additive Weibull model with bathtub-shaped failure rate function , 1996 .

[12]  Adel Nasiri,et al.  Rectifier efficiency analysis for DC distributed data centers , 2014, 2014 International Conference on Renewable Energy Research and Application (ICRERA).

[13]  Jaume Salom,et al.  Energy efficiency and renewable energy integration in data centres. Strategies and modelling review , 2015 .

[14]  Akira Matsumoto,et al.  Development of 400-Vdc output rectifier for 400-Vdc power distribution system in telecom sites and data centers , 2010, Intelec 2010.

[15]  Christopher Stewart,et al.  Concentrating renewable energy in grid-tied datacenters , 2011, Proceedings of the 2011 IEEE International Symposium on Sustainable Systems and Technology.

[16]  Jake P. Gentle,et al.  Transformer Efficiency Assessment - Okinawa, Japan , 2012 .

[17]  A. Pratt,et al.  Evaluation of 400V DC distribution in telco and data centers to improve energy efficiency , 2007, INTELEC 07 - 29th International Telecommunications Energy Conference.

[18]  Robert M. Cuzner,et al.  Does DC Distribution Make Sense? [About This Issue] , 2016 .

[19]  J. Duffie,et al.  Estimation of the diffuse radiation fraction for hourly, daily and monthly-average global radiation , 1982 .

[20]  N. Rasmussen AC vs. DC Power Distribution for Data Centers - Revision 5 , 2008 .

[21]  Bijen Raj Shrestha,et al.  Efficiency and Reliability Analysis of AC and 380V DC Data Centers , 2016 .

[22]  Reinaldo Tonkoski,et al.  Operation of datacenter as virtual power plant , 2015, 2015 IEEE Energy Conversion Congress and Exposition (ECCE).