Adaptive Theory-Based Improved Linear Sinusoidal Tracer Control Algorithm for DSTATCOM

This paper presents a hardware implementation of three-phase distribution static compensator (DSTATCOM) using an adaptive theory-based improved linear sinusoidal tracer (ILST) control algorithm for different functions of DSTATCOM such as reactive power compensation for power factor correction, harmonics elimination, load balancing, and zero-voltage regulation under linear/nonlinear loads. An ILST-based control algorithm is used for the extraction of fundamental load currents and their active and reactive power components. These components are used for the estimation of reference source currents. A prototype of DSTATCOM is developed and its real-time performance is studied using a digital signal processor. The performance of DSTATCOM is found satisfactory with the proposed control algorithm under various types of loads.

[1]  Jinjun Liu,et al.  Hybrid Cascaded H-bridge Converter for Harmonic Current Compensation , 2013, IEEE Transactions on Power Electronics.

[2]  Bhim Singh,et al.  Electronic load controller with power quality improvement of isolated induction generator for small hydro power generation , 2011 .

[3]  Wei Shi,et al.  Design Considerations for DSP-Controlled 400 Hz Shunt Active Power Filter in an Aircraft Power System , 2012, IEEE Transactions on Industrial Electronics.

[4]  Rogelio Lozano,et al.  Adaptive Control: Algorithms, Analysis and Applications , 2011 .

[5]  D. Devaraj,et al.  A Novel Fuzzy—Adaptive Hysteresis Controller Based Three Phase Four Wire-Four Leg Shunt Active Filter for Harmonic and Reactive Power Compensation , 2011 .

[6]  Qianqian Liu,et al.  A novel adaptive harmonic detecting algorithm applied to active power filters , 2010, 2010 3rd International Congress on Image and Signal Processing.

[7]  Hurng-Liahng Jou,et al.  Novel Circuit Topology for Three-Phase Active Power Filter , 2007, IEEE Transactions on Power Delivery.

[8]  Yun Wei Li,et al.  A grid fundamental and harmonic components detection method for single-phase systems , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[9]  Yun Wei Li,et al.  A Grid Fundamental and Harmonic Component Detection Method for Single-Phase Systems , 2013, IEEE Transactions on Power Electronics.

[10]  F. Blaabjerg,et al.  Detection is key - Harmonic detection methods for active power filter applications , 2007, IEEE Industry Applications Magazine.

[11]  F. Blaabjerg,et al.  Application of Discontinuous PWMModulation in Active Power Filters , 2008, IEEE Transactions on Power Electronics.

[12]  Mahesh K. Mishra,et al.  Design and Analysis of User-Defined Constant Switching Frequency Current-Control-Based Four-Leg DSTATCOM , 2009 .

[13]  B. Singh,et al.  Load Compensation for Diesel Generator Based Isolated Generation System Employing DSTATCOM , 2006, 2006 International Conference on Power Electronic, Drives and Energy Systems.

[14]  Kamal Al-Haddad,et al.  An improved control algorithm of shunt active filter for voltage regulation, harmonic elimination, power-factor correction, and balancing of nonlinear loads , 2000 .

[15]  Yupeng Tang,et al.  Active Power Filter Based on Adaptive Detecting Approach of Harmonic Currents , 2009 .

[16]  Alireza R. Bakhshai,et al.  Time-Domain Signal Analysis Using Adaptive Notch Filter , 2007, IEEE Transactions on Signal Processing.

[17]  P. Mattavelli,et al.  Cooperative Operation of Active Power Filters by Instantaneous Complex Power Control , 2007, 2007 7th International Conference on Power Electronics and Drive Systems.

[18]  Katsuhiko Ogata,et al.  Modern Control Engineering , 1970 .

[19]  M. K. Mishra,et al.  A DSTATCOM Topology With Reduced DC-Link Voltage Rating for Load Compensation With Nonstiff Source , 2012, IEEE Transactions on Power Electronics.

[20]  M. Takasaki,et al.  A Transformerless D-STATCOM Based on a Multivoltage Cascade Converter Requiring No DC Sources , 2012, IEEE Transactions on Power Electronics.

[21]  Ambra Sannino,et al.  Power-electronic solutions to power quality problems , 2003 .

[22]  A. Chandra,et al.  Integrated three-leg VSC with a zig-zag transformer based three-phase four-wire DSTATCOM for power quality improvement , 2008, 2008 34th Annual Conference of IEEE Industrial Electronics.

[23]  R.K. Varma,et al.  Nighttime Application of PV Solar Farm as STATCOM to Regulate Grid Voltage , 2009, IEEE Transactions on Energy Conversion.

[24]  Tzung-Lin Lee,et al.  Discrete Frequency-Tuning Active Filter to Suppress Harmonic Resonances of Closed-Loop Distribution Power Systems , 2011, IEEE Transactions on Power Electronics.

[25]  F. Barrero,et al.  Active power filters for line conditioning: a critical evaluation , 2000 .

[26]  N. Mariun,et al.  Review of control strategies for power quality conditioners , 2004, PECon 2004. Proceedings. National Power and Energy Conference, 2004..

[27]  F. Blaabjerg,et al.  Performance Improvement of Shunt Active Power Filter With Dual Parallel Topology , 2007, IEEE Transactions on Power Electronics.

[28]  B. Singh,et al.  Performance of Voltage and Frequency Controller in Isolated Wind Power Generation for a Three-Phase Four-Wire System , 2011, IEEE Transactions on Power Electronics.

[29]  A. Peer Fathima,et al.  A Technical Survey on Control Strategies of Active Filter for Harmonic Suppression , 2012 .

[30]  Jorge A. Solsona,et al.  Frequency Adaptive Discrete Filter for Grid Synchronization Under Distorted Voltages , 2012, IEEE Transactions on Power Electronics.

[31]  Shao-wu Du,et al.  Analysis of an improved harmonic currents detection method based on LST , 2011, 2011 2nd International Conference on Artificial Intelligence, Management Science and Electronic Commerce (AIMSEC).

[32]  Xin Li,et al.  Research on Harmonic Suppression in Power System Based on Improved Adaptive Filter , 2012 .

[33]  Su Chen,et al.  Direct power control of active filters with averaged switching frequency regulation , 2004, PESC 2004.