Purpose: To evaluate the correlation between High–Pass Resolution Perimetry (HRP) and standard threshold perimetry in patients with glaucoma or ocular hypertension. Methods: 31 glaucomatous patients and 37 ocular hypertension subjects with previous perimetric examination experience were consecutively recruited and only one eye for each patient was selected at random. Glaucomatous patients were classified as having primary open angle glaucoma when they had an abnormal visual field and/or an abnormal optic nerve head (ONH)/retinal nerve fiber layer (RNFL) typical of glaucoma, open angle at gonioscopy and no clinically apparent secondary cause for their glaucoma. Ocular hypertension subjects were defined as having intraocular pressure>21 mm Hg on no treatment, normal visual field, normal ONH and RNFL, elevated intraocular pressure without any treatment. All the subjects were examined with Humphrey Field Analyzer (HFA) 640, `program central 30-2' (Humphrey Systems, San Leandro, CA, USA) and with High–Pass Resolution Perimeter (HRP), Ophthimus version 2.4, `ring program' (Nikon-HighTech Vision, Goteborg, Sweden). Visual field indices were obtained with both systems: for HFA mean deviation (MD), corrected pattern standard deviation (CPSD) and short term fluctuation (SF), while for HRP global deviation (GD), local deviation (LD), form index (FI) and neural capacity (NC). The data were analyzed by descriptive analysis, Student's t test with Bonferroni's correction or Mann-Whitney non-parametric test and Pearson or Spearman's correlation coefficient.Results: A significant correlation was found between MD and GD (r = -0.81), CPSD and LD (r = 0.87), PSD and LD (r = 0.72). NC was significantly correlated with MD (r = 0.76), GD (r = -0.94). FI was significantly correlated with PSD (r = -0.58), CPSD (r = -0.72), LD (r = -0.56).When the same data were analyzed for the glaucomatous group only, similar results were found; in the ocular hypertensive group no significant correlation was found except between NC and MD (r = 0.52).Conclusion: HRP indices vary comparably with HFA indices. Parameters as NC and FI were significantly correlated with standard visual field indices of both HFA and HRP. Although the clinical applications for FI are not clear yet, NC could detect both early glaucomatous damage and age related changes.
[1]
N. Swindale,et al.
Sector‐Based Analysis of Optic Nerve Head Shape Parameters and Visual Field Indices in Healthy and Glaucomatous Eyes
,
1997,
Journal of glaucoma.
[2]
R. Weinreb,et al.
High-pass resolution perimetry in eyes with ocular hypertension and primary open-angle glaucoma.
,
1992,
American journal of ophthalmology.
[3]
B. Chauhan,et al.
Intratest variability in conventional and high-pass resolution perimetry.
,
1991,
Ophthalmology.
[4]
R. Leblanc,et al.
Comparison of high-pass resolution perimetry and pattern discrimination perimetry to conventional perimetry in glaucoma.
,
1993,
Canadian journal of ophthalmology. Journal canadien d'ophtalmologie.
[5]
W R Green,et al.
Chronic human glaucoma causing selectively greater loss of large optic nerve fibers.
,
1988,
Ophthalmology.
[6]
D. Hubel,et al.
Spatial and chromatic interactions in the lateral geniculate body of the rhesus monkey.
,
1966,
Journal of neurophysiology.
[7]
N. Swindale,et al.
Comparison of psychophysical and electrophysiological testing in early glaucoma.
,
1996,
Investigative ophthalmology & visual science.
[8]
Lars Frisén,et al.
A computer-graphics visual field screener using high-pass spatial frequency resolution targets and multiple feedback devices
,
1987
.
[9]
J. M. Miller,et al.
Correlation of structure and function in glaucoma. Quantitative measurements of disc and field.
,
1988,
Ophthalmology.
[10]
L. Frisén,et al.
High-pass resolution perimetry
,
1993,
Documenta Ophthalmologica.
[11]
H. Chung,et al.
Comparison between high-pass resolution perimetry and differential light sensitivity perimetry in patients with glaucoma.
,
1998,
Journal of glaucoma.