Temporary use of shape memory spinal rod in the treatment of scoliosis

NiTinol shape memory alloy is characterized by its malleability at low temperatures and its ability to return to a preconfigured shape above its activation temperature. This process can be utilized to assist in scoliosis correction. The goal of this retrospective study was to evaluate the clinical and radiographic results of intraoperative use of shape memory alloy rod in the correction of scoliosis. From May 2002 to September 2006, 38 scoliosis patients (ranging from 50° to 120°; 22 cases over 70°) who underwent shape memory alloy-assisted correction in our institute were reviewed. During the operation, a shape memory alloy rod served as a temporary correction tool. Following correction, the rod was replaced by a rigid rod. The mean blood loss at surgery was 680 ± 584 ml; the mean operative time was 278 ± 62 min. The major Cobb angle improved from an average 78.4° preoperatively to 24.3° postoperatively (total percent correction 71.4%). In 16 patients with a major curve <70° and flexibility of 52.7%, the deformity improved from 58.4° preoperatively to 12.3° postoperatively (percent correction, 78.9%). In 22 patients with a major curve >70° and flexibility of 25.6%, the deformity improved from 94.1° preoperatively to 30.1° postoperatively (percent correction, 68.1%). Only one case had a deep infection. There were no neurologic, vascular or correction-related complications such as screw pullout or metal fracture. The study shows that the intraoperative use of a shape memory rod is a safe and effective method to correct scoliosis.

[1]  R. Delamarter,et al.  Metal debris from titanium spinal implants. , 1999, Spine.

[2]  U Liljenqvist,et al.  Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine. , 2001, Acta orthopaedica Belgica.

[3]  G. Ethévenot,et al.  Clinical Experience with a New Nitinol Self-Expanding Stent in Peripheral Arteries , 1996, Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery.

[4]  A. Veldhuizen,et al.  Scoliosis correction with shape-memory metal: results of an experimental study , 2002, European Spine Journal.

[5]  L. Lenke,et al.  Correction of Thoracic Adolescent Idiopathic Scoliosis With Segmental Hooks, Rods, and Wisconsin Wires Posteriorly: It’s Bad and Obsolete, Correct? , 2002, Spine.

[6]  M. Ylikoski,et al.  Harrington and Cotrel-Dubousset instrumentation in adolescent idiopathic scoliosis. Long-term functional and radiographic outcomes. , 2003, The Journal of bone and joint surgery. American volume.

[7]  J. Schramm,et al.  Corrosion on an internal spinal fixator system. , 1999, Spine.

[8]  J Dubousset,et al.  NEW UNIVERSAL INSTRUMENTATION IN SPINAL SURGERY , 1988, Clinical orthopaedics and related research.

[9]  R. Betz,et al.  An Innovative Technique of Vertebral Body Stapling for the Treatment of Patients With Adolescent Idiopathic Scoliosis: A Feasibility, Safety, and Utility Study , 2003, Spine.

[10]  A. Szold Nitinol: shape-memory and super-elastic materials in surgery , 2005, Surgical Endoscopy And Other Interventional Techniques.

[11]  R B Ashman,et al.  A Preliminary Investigation of Shape Memory Alloys in the Surgical Correction of Scoliosis , 1993, Spine.

[12]  J. Ogilvie,et al.  Relative Versus Absolute Modulation of Growth in the Fusionless Treatment of Experimental Scoliosis , 2006, Spine.

[13]  H Labelle,et al.  Comparison Between Preoperative and Postoperative Three‐dimensional Reconstructions of Idiopathic Scoliosis With the Cotrel‐dubousset Procedure , 1995, Spine.

[14]  T R Haher,et al.  Meta‐analysis of Surgical Outcome in Adolescent Idiopathic Scoliosis: A 35‐Year English Literature Review of 11,000 Patients , 1995, Spine.

[15]  C. K. Lee,et al.  Segmental Pedicle Screw Fixation in the Treatment of Thoracic Idiopathic Scoliosis , 1995, Spine.

[16]  C. Puttlitz,et al.  A Biomechanical Assessment of Thoracic Spine Stapling , 2007, Spine.

[17]  W. Achatz,et al.  Direct Stabilization of Lumbar Spondylolysis With a Hook Screw: Mean 11-Year Follow-up Period for 113 Patients , 2003, Spine.

[18]  Farida Cheriet,et al.  A three-dimensional retrospective analysis of the evolution of spinal instrumentation for the correction of adolescent idiopathic scoliosis , 2008, European spine journal.

[19]  F. Orsi,et al.  Self-expandable nitinol stent for the management of biliary obstruction: long-term clinical results. , 1994, Journal of vascular and interventional radiology : JVIR.

[20]  P. R. Harrington,et al.  Treatment of scoliosis. Correction and internal fixation by spine instrumentation. , 1962, The Journal of bone and joint surgery. American volume.

[21]  Sang Min Lee,et al.  Direct Vertebral Rotation: A New Technique of Three-Dimensional Deformity Correction With Segmental Pedicle Screw Fixation in Adolescent Idiopathic Scoliosis , 2004, Spine.

[22]  M. Schmerling,et al.  Using the shape recovery of nitinol in the Harrington rod treatment of scoliosis. , 1976, Journal of biomedical materials research.

[23]  K. Bridwell,et al.  Surgical treatment of idiopathic adolescent scoliosis. , 1999, Spine.