Experimental and numerical assessment of MRI‐induced temperature change and SAR distributions in phantoms and in vivo

It is important to accurately characterize the heating of tissues due to the radiofrequency energy applied during MRI. This has led to an increase in the use of numerical methods to predict specific energy absorption rate distributions for safety assurance in MRI. To ensure these methods are accurate for actual MRI coils, however, it is necessary to compare to experimental results. Here, we report results of some recent efforts to experimentally map temperature change and specific energy absorption rate in a phantom and in vivo where the only source of heat is the radiofrequency fields produced by the imaging coil. Results in a phantom match numerical simulation well, and preliminary results in vivo show measurable temperature increase. With further development, similar methods may be useful for verifying numerical methods for predicting specific energy absorption rate distributions and in some cases for directly measuring temperature changes and specific energy absorption rate induced by the radiofrequency fields in MRI experiments. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.

[1]  R. Mallozzi,et al.  Radiofrequency power deposition utilizing thermal imaging , 2004, Magnetic resonance in medicine.

[2]  C. Collins,et al.  Calculations ofB1 distribution, specific energy absorption rate, and intrinsic signal-to-noise ratio for a body-size birdcage coil loaded with different human subjects at 64 and 128 MHz , 2005, Applied magnetic resonance.

[3]  Christopher M Collins,et al.  Numerical field calculations considering the human subject for engineering and safety assurance in MRI , 2009, NMR in biomedicine.

[4]  Bruno Quesson,et al.  Magnetic resonance temperature imaging for guidance of thermotherapy , 2000, Journal of magnetic resonance imaging : JMRI.

[5]  A. Borthakur,et al.  Fast MRI of RF heating via phase difference mapping , 2002, Magnetic resonance in medicine.

[6]  Andrew G. Webb,et al.  Optimization of electromagnetic phased-arrays for hyperthermia via magnetic resonance temperature estimation , 2002, IEEE Transactions on Biomedical Engineering.

[7]  Emmanuel Perrin,et al.  RF‐induced temperature elevation along metallic wires in clinical magnetic resonance imaging: Influence of diameter and length , 2004, Magnetic resonance in medicine.

[8]  Christopher M Collins,et al.  Calculation of SAR for Transmit Coil Arrays. , 2007, Concepts in magnetic resonance. Part B, Magnetic resonance engineering.

[9]  Arijitt Borthakur,et al.  MR imaging of RF heating using a paramagnetic doped agarose phantom , 2000, Magnetic Resonance Materials in Physics, Biology and Medicine.

[10]  Ferdinand Schweser,et al.  SAR in Parallel Transmission , 2008 .

[11]  I. Graesslin,et al.  Comprehensive RF Safety Concept for Parallel Transmission Systems , 2007 .

[12]  Michael B. Smith,et al.  SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil , 1998, Magnetic resonance in medicine.

[13]  C. Findeklee,et al.  Experimental estimation of local SAR in a multi-transmit system , 2008 .

[14]  M Alecci,et al.  Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: Experimental and theoretical dependence on sample properties , 2001, Magnetic resonance in medicine.

[15]  H. H. Pennes Analysis of tissue and arterial blood temperatures in the resting human forearm. , 1948, Journal of applied physiology.

[16]  O. Beuf,et al.  RF induced temperature elevation near metallic wires in clinical magnetic resonance imaging , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[17]  Paolo Bernardi,et al.  Specific absorption rate and temperature elevation in a subject exposed in the far-field of radio-frequency sources operating in the 10-900-MHz range , 2003, IEEE Transactions on Biomedical Engineering.