Tracking simultaneous time-varying power harmonic distortions using filter banks

Although it is well known that the Fourier analysis is only accurately applicable to steady-state waveforms, it is a widely used tool to study and monitor time-varying signals, such as are commonplace in electrical power systems. The disadvantages of the Fourier analysis, such as frequency spillover or problems due to sampling (data window) truncation can often be minimized by various windowing techniques, but they nevertheless exist. This paper demonstrates that it is possible to track and visualize amplitude and time-varying power systems harmonics, without frequency spillover caused by classical time-frequency techniques. This new tool allows for a clear visualization of time-varying harmonics, which can lead to better ways to track harmonic distortion and understand time-dependent power quality parameters. It has been applied to extract the harmonic contents of a rolling mill. It also has the potential to assist with control and protection applications.

[1]  M. Karimi-Ghartemani,et al.  A technique for extracting time-varying harmonics based on an adaptive notch filter , 2005, Proceedings of 2005 IEEE Conference on Control Applications, 2005. CCA 2005..

[2]  G. H. Allen,et al.  A new filter-bank configuration for harmonic measurement , 1996 .

[3]  P. F. Ribeiro,et al.  Time-Varying Harmonic Distortion Estimation Using PLL Based Filter Bank and Multirate Processing , .

[4]  T. H. Ortmeyer,et al.  Evaluation of current interharmonics from AC drives , 2000 .

[5]  A. Testa,et al.  Desynchronized Processing technique for Harmonic and interharmonic analysis , 2004, IEEE Transactions on Power Delivery.

[6]  P. Lehn,et al.  Interharmonics: Theory and Modeling , 2007, IEEE Transactions on Power Delivery.

[7]  C. R. Mason,et al.  The Art and Science of Protective Relaying , 1956 .

[8]  Kit Po Wong,et al.  Wavelet-transform-based algorithm for harmonic analysis of power system waveforms , 1999 .

[9]  K. Wong,et al.  Antidistortion method for wavelet transform filter banks and nonstationary power system waveform harmonic analysis , 2001 .

[10]  M.H.J. Bollen,et al.  Estimating Interharmonics by Using Sliding-Window ESPRIT , 2008, IEEE Transactions on Power Delivery.

[11]  S.-L. Lu,et al.  Application of DFT filter bank to power frequency harmonic measurement , 2005 .

[12]  Math Bollen,et al.  Time-frequency and time-scale domain analysis of voltage disturbances , 2000 .

[13]  W. Marsden I and J , 2012 .

[14]  Z. Gajic,et al.  Power Transformer Characteristics and Their Effects on Protective Relays , 2007, 2007 60th Annual Conference for Protective Relay Engineers.

[15]  F. Ashcroft,et al.  VIII. References , 1955 .

[16]  Robert Bregovic,et al.  Multirate Systems and Filter Banks , 2002 .

[17]  Paulo F. Ribeiro,et al.  Using Wavelet Decomposition for Visualization and Understanding of Time-Varying Waveform Distortion in Power Systems , 2007 .

[18]  P.F. Ribeiro,et al.  Novel method for tracking time-varying power harmonic distortions without frequency spillover , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[19]  Sanjit K. Mitra,et al.  Digital Signal Processing: A Computer-Based Approach , 1997 .

[20]  Wilsun Xu,et al.  Interharmonics: basic concepts and techniques for their detection and measurement , 2003 .