Using a modified electrical aerosol detector to predict nanoparticle exposures to different regions of the respiratory tract for workers in a carbon black manufacturing industry.

The present study was set out to characterize nanoparticle exposures in three selected workplaces of the packaging, warehouse, and pelletizing in a carbon black manufacturing plant using a newly developed modified electrical aerosol detector (MEAD). For confirmation purposes, the MEAD results were compared with those simultaneously obtained from a nanoparticle surface area monitor (NSAM) and a scanning mobility particle sizer (SMPS). We found that workplace background nanoparticle concentrations were mainly coming from the outdoor environment. Size distributions of nanoparticles for the three selected process areas during the work hours were consistently in the form of bimodel. Unlike nanoparticles of the second mode (simply contributed by the process emissions), particles of the first mode could be also contributed by the forklift exhaust or fugitive emissions of heaters. The percents of nanoparticles deposited on the alveolar (A) region were much higher than the other two regions of the head airway (H), tracheobronchial (TB) for all selected workplaces in both number and surface area concentrations. However, significant differences were found in percents of nanoparticles deposited on each of the three regions while different exposure metrics were adopted. Both NSAM and MEAD obtained quite comparable results. No significant difference can be found between the results obtained from SMPS and MEAD after being normalized. Considering the MEAD is less expensive, less bulky, and easy to use, our results further support the suitability of using MEAD in the field for nanoparticle exposure assessments.

[1]  J. Heyder,et al.  Instillation of Six Different Ultrafine Carbon Particles Indicates a Surface Area Threshold Dose for Acute Lung Inflammation in Mice , 2005, Environmental health perspectives.

[2]  A. Zuckerman,et al.  IARC Monographs on the Evaluation of Carcinogenic Risks to Humans , 1995, IARC monographs on the evaluation of carcinogenic risks to humans.

[3]  James S. Brown,et al.  Ultrafine particle deposition and clearance in the healthy and obstructed lung. , 2002, American journal of respiratory and critical care medicine.

[4]  E. Oberdörster Manufactured Nanomaterials (Fullerenes, C60) Induce Oxidative Stress in the Brain of Juvenile Largemouth Bass , 2004, Environmental health perspectives.

[5]  K. Donaldson,et al.  Inhalation of poorly soluble particles. II. Influence Of particle surface area on inflammation and clearance. , 2000, Inhalation toxicology.

[6]  Güunter Oberdürster Toxicology of ultrafine particles: in vivo studies , 2000, Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[7]  W. MacNee,et al.  Short-term inflammatory responses following intratracheal instillation of fine and ultrafine carbon black in rats. , 1999, Inhalation toxicology.

[8]  A. Peters,et al.  Respiratory effects are associated with the number of ultrafine particles. , 1997, American journal of respiratory and critical care medicine.

[9]  G. Oberdörster,et al.  Pulmonary effects of inhaled ultrafine particles , 2000, International archives of occupational and environmental health.

[10]  G. Oberdörster,et al.  Pulmonary retention of ultrafine and fine particles in rats. , 1992, American journal of respiratory cell and molecular biology.

[11]  H. Fissan,et al.  Rationale and principle of an instrument measuring lung deposited nanoparticle surface area , 2006 .

[12]  Wen-Jhy Lee,et al.  Characterization of PAHs in the atmosphere of carbon black manufacturing workplaces. , 2002, Journal of hazardous materials.

[13]  Robert Gelein,et al.  Effects of subchronically inhaled carbon black in three species. I. Retention kinetics, lung inflammation, and histopathology. , 2005, Toxicological sciences : an official journal of the Society of Toxicology.

[14]  W. MacNee,et al.  Ultrafine (nanometre) particle mediated lung injury , 1998 .

[15]  William E. Wilson,et al.  Use of the Electrical Aerosol Detector as an Indicator of the Surface Area of Fine Particles Deposited in the Lung , 2007, Journal of the Air & Waste Management Association.

[16]  David Y. H. Pui,et al.  Use of Continuous Measurements of Integral Aerosol Parameters to Estimate Particle Surface Area , 2001 .

[17]  W. Kreyling,et al.  TRANSLOCATION OF ULTRAFINE INSOLUBLE IRIDIUM PARTICLES FROM LUNG EPITHELIUM TO EXTRAPULMONARY ORGANS IS SIZE DEPENDENT BUT VERY LOW , 2002, Journal of toxicology and environmental health. Part A.

[18]  Perng-Jy Tsai,et al.  Evaluation of an electrical aerosol detector (EAD) for the aerosol integral parameter measurement , 2009 .

[19]  Da-Ren Chen,et al.  Use of an electrical aerosol detector (EAD) for nanoparticle size distribution measurement , 2009 .

[20]  M. Kakeyama,et al.  Brain cytokine and chemokine mRNA expression in mice induced by intranasal instillation with ultrafine carbon black. , 2006, Toxicology letters.

[21]  Takahiro Kobayashi,et al.  Chemical and biological oxidative effects of carbon black nanoparticles. , 2006, Chemosphere.

[22]  T A J Kuhlbusch,et al.  Number Size Distribution, Mass Concentration, and Particle Composition of PM1, PM2.5, and PM10 in Bag Filling Areas of Carbon Black Production , 2004, Journal of occupational and environmental hygiene.

[23]  D. Dockery,et al.  An association between air pollution and mortality in six U.S. cities. , 1993, The New England journal of medicine.

[24]  David Brown,et al.  The pulmonary toxicology of ultrafine particles. , 2002, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[25]  G. Oberdörster,et al.  Significance of particle parameters in the evaluation of exposure-dose-response relationships of inhaled particles , 1996 .

[26]  Derk H Brouwer,et al.  Personal exposure to ultrafine particles in the workplace: exploring sampling techniques and strategies. , 2004, The Annals of occupational hygiene.