Local buckling studies of cold-formed steel compression members at elevated temperatures

Cold-formed steel members have been widely used in residential and commercial buildings as primary load bearing structural elements. They are often made of thin steel sheets and hence they are more susceptible to local buckling. The buckling behaviour of cold-formed steel compression members under fire conditions is not fully investigated yet and hence there is a lack of knowledge on the fire performance of cold-formed steel compression members. Current cold-formed steel design standards do not provide adequate design guidelines for the fire design of cold-formed steel compression members. Therefore a research project based on extensive experimental and numerical studies was undertaken to investigate the local buckling behaviour of light gauge cold-formed steel compression members under simulated fire conditions. First a series of 91 local buckling tests was conducted at ambient and uniform elevated temperatures up to 700oC on cold-formed lipped and unlipped channels. Suitable finite element models were then developed to simulate the behaviour of tested columns and were validated using test results. All the ultimate load capacity results for local buckling were compared with the predictions from the available design rules based on AS/NZS 4600, BS 5950 Part 5, Eurocode 3 Parts 1.2 and 1.3 and the direct strength method (DSM), based on which suitable recommendations have been made for the fire design of cold-formed steel compression members subject to local buckling at uniform elevated temperatures.

[1]  Dinar Camotim,et al.  GBT-based Structural Analysis of Thin-walled members: Overview, Recent Progress and Future Developments , 2006 .

[2]  Mahen Mahendran,et al.  Numerical modelling of light gauge cold-formed steel compression members subjected to distortional buckling at elevated temperatures , 2010 .

[3]  Mahen Mahendran,et al.  Experimental study of the mechanical properties of light gauge cold-formed steels at elevated temperatures , 2009 .

[4]  J. M. Davies,et al.  A numerical imperfection sensitivity study of cold-formed thin-walled tubular steel columns at uniform elevated temperatures , 2004 .

[5]  Benjamin W. Schafer,et al.  Computational modeling of cold-formed steel: characterizing geometric imperfections and residual stresses , 1998 .

[6]  Yong Wang,et al.  Structural behaviour of cold-formed thin-walled short steel channel columns at elevated temperatures. Part 1: experiments , 2003 .

[7]  Thanuja Ranawaka Distortional buckling behaviour of cold-formed steel compression members at elevated temperatures , 2006 .

[8]  Yasintha Bandula Heva Behaviour and design of cold-formed steel compression members at elevated temperatures , 2014 .

[9]  Gregory J. Hancock,et al.  Development of the 2005 Edition of the Australian/New Zealand Standard for Cold-Formed Steel Structures AS/NZS 4600 , 2008 .

[10]  Ben Young,et al.  Cold-formed steel lipped channel columns at elevated temperatures , 2006 .

[11]  Mahen Mahendran,et al.  Distortional buckling tests of cold-formed steel compression members at elevated temperatures , 2009 .

[12]  Chanakya Arya,et al.  Eurocode 3: Design of steel structures , 2018, Design of Structural Elements.

[13]  J M Davies,et al.  Structural behaviour of cold-formed thin-walled short steel channel columns at elevated temperatures. Part 2: Design calculations and numerical analysis , 2003 .

[14]  Viorel Ungureanu,et al.  Effect of imperfections on numerical simulation of instability behaviour of cold-formed steel members , 2002 .

[15]  Frank Fleer,et al.  Australian / New Zealand standards , 1996 .