Mechanical validation of whole bone composite femur models.

Composite synthetic models of the human femur have recently become commercially available as substitutes for cadaveric specimens. Their quick diffusion was justified by the advantages they offer as a substitute for real femurs. The present investigation concentrated on an extensive experimental validation of the mechanical behaviour of the whole bone composite model, compared to human fresh-frozen and dried-rehydrated specimens for different loading conditions. First, the viscoelastic behaviour of the models was investigated under simulated single leg stance loading, showing that the little time dependent phenomena observed tend to extinguish within a few minutes of the load application. The behaviour under axial loading was then studied by comparing the vertical displacement of the head as well as the axial strains, by application of a parametric descriptive model of the strain distribution. Finally, a four point bending test and a torsional test were performed to characterize the whole bone stiffness of the femur. In all these tests, the composite femurs were shown to fall well within the range for cadaveric specimens, with no significant differences being detected between the synthetic femurs and the two groups of cadaveric femurs. Moreover, the interfemur variability for the composite femurs was 20-200 times lower than that for the cadaveric specimens, thus allowing smaller differences to be characterized as significant using the same simple size, if the composite femurs are employed.

[1]  N Berme,et al.  Determination of the transverse elastic coefficients of bone. , 1977, Journal of biomechanics.

[2]  J. Szivek,et al.  Characterization of a synthetic foam as a model for human cancellous bone. , 1993, Journal of applied biomaterials : an official journal of the Society for Biomaterials.

[3]  R. Gustilo,et al.  Synthetic composite femurs for use in evaluation of torsional stability of cementless femoral prostheses , 1989 .

[4]  L. Whiteside,et al.  Effects of femoral component material properties on cementless fixation in total hip arthroplasty. A comparison study between carbon composite, titanium alloy, and stainless steel. , 1993, The Journal of arthroplasty.

[5]  L. Whiteside,et al.  Strain distribution in the proximal femur with flexible composite and metallic femoral components under axial and torsional loads. , 1993, Journal of biomedical materials research.

[6]  A Rohlmann,et al.  Finite-element-analysis and experimental investigation in a femur with hip endoprosthesis. , 1983, Journal of biomechanics.

[7]  Mk Butts,et al.  Testing Method for Evaluating Bending Stiffness and Torsional Stability of Femurs Implanted with Intramedullary Nails , 1989 .

[8]  D R Carter,et al.  Mechanical properties and composition of cortical bone. , 1978, Clinical orthopaedics and related research.

[9]  John A. Szivek,et al.  Variability in the torsional and bending response of a commercially available composite “Femur” , 1990 .

[10]  R Van Audekercke,et al.  The mechanical characteristics of cancellous bone at the upper femoral region. , 1983, Journal of biomechanics.

[11]  W. Hayes,et al.  Cross-sectional geometry of Pecos Pueblo femora and tibiae--a biomechanical investigation: I. Method and general patterns of variation. , 1983, American journal of physical anthropology.

[12]  R. Crowninshield,et al.  An analysis of femoral component stem design in total hip arthroplasty. , 1980, The Journal of bone and joint surgery. American volume.

[13]  John D. Currey,et al.  Anelasticity in Bone and Echinoderm Skeletons , 1965 .

[14]  B P McNamara,et al.  A minimal parametric model of the femur to describe axial elastic strain in response to loads. , 1996, Medical engineering & physics.

[15]  H. Tullos,et al.  The anatomic basis of femoral component design. , 1988, Clinical orthopaedics and related research.

[16]  R. Lakes,et al.  Viscoelastic properties of wet cortical bone--II. Relaxation mechanisms. , 1979, Journal of biomechanics.

[17]  J. Szivek,et al.  Comparison of the deformation response of synthetic and cadaveric femora during simulated one-legged stance. , 1991, Journal of applied biomaterials : an official journal of the Society for Biomaterials.

[18]  N. Sasaki,et al.  Stress relaxation function of bone and bone collagen. , 1993, Journal of biomechanics.

[19]  J. Currey,et al.  The effects of drying and re-wetting on some mechanical properties of cortical bone. , 1988, Journal of biomechanics.

[20]  S Uta,et al.  [Development of synthetic bone models for the evaluation of fracture fixation devices]. , 1992, Nihon Seikeigeka Gakkai zasshi.

[21]  R Huiskes,et al.  On the modelling of long bones in structural analyses. , 1982, Journal of biomechanics.

[22]  P G Niederer,et al.  Comparison of the stability of press‐fit hip prosthesis femoral stems using a synthetic model femur , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[23]  R. Lakes,et al.  Viscoelastic properties of wet cortical bone--I. Torsional and biaxial studies. , 1979, Journal of biomechanics.

[24]  R. Lakes,et al.  Viscoelastic properties of wet cortical bone--III. A non-linear constitutive equation. , 1979, Journal of biomechanics.

[25]  R. Huiskes,et al.  The Mechanical Performance of Solid and Porous Bone Cement , 1982 .

[26]  A. Burstein,et al.  The elastic and ultimate properties of compact bone tissue. , 1975, Journal of biomechanics.

[27]  D R Pedersen,et al.  A measurement of proximal femur strain with total hip arthroplasty. , 1980, Journal of Biomechanical Engineering.

[28]  M. Singh,et al.  Changes in trabecular pattern of the upper end of the femur as an index of osteoporosis. , 1970, The Journal of bone and joint surgery. American volume.

[29]  L Cristofolini,et al.  Initial stability of uncemented hip stems: an in-vitro protocol to measure torsional interface motion. , 1995, Medical engineering & physics.