Reference-Free Adjustment of Respiratory Inductance Plethysmography for Measurements during Physical Exercise

Objective: Respiratory inductance plethysmography (RIP) provides an unobtrusive method for measuring breathing characteristics. Accurately adjusted RIP provides reliable measurements of ventilation during rest and exercise if data are acquired via two elastic measuring bands surrounding the rib cage (RC) and abdomen (AB). Disadvantageously, the most accurate reported adjusted model for RIP in literature—least squares regression—requires simultaneous RIP and flowmeter (FM) data acquisition. An adjustment method without simultaneous measurement (reference-free) of RIP and FM would foster usability enormously. Methods: In this paper, we develop generalizable, functional, and reference-free algorithms for RIP adjustment incorporating anthropometric data. Further, performance of only one-degree of freedom (RC or AB) instead of two (RC and AB) is investigated. We evaluate the algorithms with data from 193 healthy subjects who performed an incremental running test using three different datasets: training, reliability, and validation dataset. The regression equation is improved with machine learning techniques such as sequential forward feature selection and 10-fold cross validation. Results: Using the validation dataset, the best reference-free adjustment model is the combination of both bands with 84.69% breaths within $\pm$  20% limits of equivalence compared to 43.63% breaths using the best comparable algorithm from literature. Using only one band, we obtain better results using the RC band alone. Conclusion: Reference-free adjustment for RIP reveals tidal volume differences of up to 0.25 l when comparing to the best possible adjustment currently present which needs the simultaneous measurement of RIP and FM. Significance: This demonstrates that RIP has the potential for usage in wide applications in ambulatory settings.

[1]  M. Mahar,et al.  The Bland-Altman Method Should Not Be Used in Regression Cross-Validation Studies , 2011, Research quarterly for exercise and sport.

[2]  S. Loring,et al.  A simple and reliable method to calibrate respiratory magnetometers and Respitrace. , 1995, Journal of applied physiology.

[3]  J. Stocks,et al.  Reference values for residual volume, functional residual capacity and total lung capacity. ATS Workshop on Lung Volume Measurements. Official Statement of The European Respiratory Society. , 1995, The European respiratory journal.

[4]  R. Gonzalez Applied Multivariate Statistics for the Social Sciences , 2003 .

[5]  Heike Leutheuser,et al.  Respiratory inductance plethysmography-a rationale for validity during exercise. , 2014, Medicine and science in sports and exercise.

[6]  J. Davis,et al.  Computer-aided measurement of breath volume and time components using magnetometers. , 1978, Journal of applied physiology: respiratory, environmental and exercise physiology.

[7]  R. Welsch,et al.  The Hat Matrix in Regression and ANOVA , 1978 .

[8]  A. de Groote,et al.  Mathematical assessment of qualitative diagnostic calibration for respiratory inductive plethysmography. , 2001, Journal of applied physiology.

[9]  W. J. Langford Statistical Methods , 1959, Nature.

[10]  B. Krieger,et al.  Calibration of respiratory inductive plethysmograph during natural breathing. , 1989, Journal of applied physiology.

[11]  J H Auchincloss,et al.  Changes in tidal volume, frequency, and ventilation induced by their measurement. , 1972, Journal of applied physiology.

[12]  Konrad E. Bloch,et al.  Respiratory Monitoring by Inductive Plethysmography in Unrestrained Subjects Using Position Sensor-Adjusted Calibration , 2009, Respiration.

[13]  S. Teramoto,et al.  A comparison of ventilation components in young and elderly men during exercise. , 1995, The journals of gerontology. Series A, Biological sciences and medical sciences.

[14]  J. Stocks,et al.  REFERENCE V VALUES F FOR R RESIDUAL V VOLUME, F FUNCTIONAL RESIDUAL C CAPACITY A AND T TOTAL L LUNG C CAPACITY , 1995 .

[15]  P. Mahalanobis On the generalized distance in statistics , 1936 .

[16]  Björn Eskofier,et al.  Comparison of a priori calibration models for respiratory inductance plethysmography during running , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[17]  M. Sackner,et al.  Validation of respiratory inductive plethysmography using different calibration procedures. , 2015, The American review of respiratory disease.

[18]  Frank H Wilhelm,et al.  The LifeShirt , 2003, Behavior modification.

[19]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[20]  J. Mead,et al.  Measurement of the separate volume changes of rib cage and abdomen during breathing. , 1967, Journal of applied physiology.

[21]  John Staudenmayer,et al.  Improved regression models for ventilation estimation based on chest and abdomen movements , 2012, Physiological measurement.

[22]  I A Greaves,et al.  Estimates of ventilation from body surface measurements in unrestrained subjects. , 1986, Journal of applied physiology.

[23]  J M Kinney,et al.  Effects of respiratory apparatus on breathing pattern. , 1980, Journal of applied physiology: respiratory, environmental and exercise physiology.