Dynamic Link Library and Signal Conditioning System for Electrical Impedance Tomography Virtual Instrumentation

This paper presents the implementation of a Dynamic Link Library (DLL) and Signal Conditioning System for on-line qualitative reconstruction and analysis of Electrical Impedance Tomography (EIT) images. Three different finite element circular meshes were developed for use with the DLL: 104, 464 and 1016 triangular elements. The library allows the user to choose between three different post-reconstruction options for data visualization: raw data, bilinear interpolation and radial basis function (RBF) interpolation. The DLL can thus be imported into a Virtual Instrumentation software, such as National Instruments LabWindows© and Agilent Technologies HPVEE© to ease the implementation of virtual instrumentation for EIT measurements. A case study is presented: in-phantom object tracking in laboratory test trials. The results suggest that the EIT DLL can be used as part of a virtual instrumentation program, reducing development time for on-line real-time analysis in multiple applications.

[1]  Itziar Cabanes,et al.  Design of a Virtual-Instrumentation System for a Machining Process , 2007, IEEE Transactions on Instrumentation and Measurement.

[2]  David S. Holder,et al.  Electrical Impedance Tomography : Methods, History and Applications , 2004 .

[3]  A. G. Chávez,et al.  Soil water infiltration measurements using electrical impedance tomography , 2012 .

[4]  David Isaacson,et al.  Electrical Impedance Tomography , 1999, SIAM Rev..

[5]  Wieslaw Winiecki,et al.  A Low-Cost Real-Time Virtual Spectrum Analyzer , 2005, 2005 IEEE Instrumentationand Measurement Technology Conference Proceedings.

[6]  Emil Jovanov,et al.  Virtual Instrumentation , 2002 .

[7]  F. J. Dickin,et al.  SPARSE MATRIX METHODS FOR USE IN ELECTRICAL IMPEDANCE TOMOGRAPHY , 1997 .

[8]  William R B Lionheart,et al.  Uses and abuses of EIDORS: an extensible software base for EIT , 2006, Physiological measurement.

[9]  Trevor A. York Status of electrical tomography in industrial applications , 2001, J. Electronic Imaging.

[10]  Marko Vauhkonen,et al.  Suitability of a PXI platform for an electrical impedance tomography system , 2008 .

[11]  J. Antonio,et al.  Evaluation of Methods for On-line Image Analysis of Electrical Impedance Tomography Images. , 2007, Electronics, Robotics and Automotive Mechanics Conference (CERMA 2007).

[12]  J. A. Gutierrez‐Gnecchi,et al.  Control of a Pilot‐Scale, Solid‐Liquid Separation Plant Using Electrical Impedance Tomography Measurements , 2008 .