All-integrated and highly sensitive paper based device with sample treatment platform for Cd2+ immunodetection in drinking/tap waters.

Nowadays, the development of systems, devices, or methods that integrate several process steps into one multifunctional step for clinical, environmental, or industrial purposes constitutes a challenge for many ongoing research projects. Here, we present a new integrated paper based cadmium (Cd(2+)) immunosensing system in lateral flow format, which integrates the sample treatment process with the analyte detection process. The principle of Cd(2+) detection is based on competitive reaction between the cadmium-ethylenediaminetetraacetic acid-bovine serum albumin-gold nanoparticles (Cd-EDTA-BSA-AuNP) conjugate deposited on the conjugation pad strip and the Cd-EDTA complex formed in the analysis sample for the same binding sites of the 2A81G5 monoclonal antibody (mAb), specific to Cd-EDTA but not Cd(2+) free, which is immobilized onto the test line. This platform operates without any sample pretreatment step for Cd(2+) detection thanks to an extra conjugation pad that ensures Cd(2+) complexation with EDTA and interference masking through ovalbumin (OVA). The detection and quantification limits found for the device were 0.1 and 0.4 ppb, respectively, these being the lowest limits reported up to now for metal sensors based on paper. The accuracy of the device was evaluated by addition of known quantities of Cd(2+) to different drinking water samples and subsequent Cd(2+) content analysis. Sample recoveries ranged from 95 to 105% and the coefficient of variation for the intermediate precision assay was less than 10%. In addition, the results obtained here were compared with those obtained with the well-established inductively coupled plasma emission spectroscopy (ICPES) and the analysis of certificate standard samples.

[1]  Yi Lu,et al.  Small-molecule diagnostics based on functional DNA nanotechnology: a dipstick test for mercury. , 2011, Faraday discussions.

[2]  Chong H. Ahn,et al.  A polymer lab chip sensor with microfabricated planar silver electrode for continuous and on-site heavy metal measurement , 2011 .

[3]  S. Hossain,et al.  β-Galactosidase-based colorimetric paper sensor for determination of heavy metals. , 2011, Analytical chemistry.

[4]  W. Dungchai,et al.  Lab-on-paper with dual electrochemical/colorimetric detection for simultaneous determination of gold and iron. , 2010, Analytical chemistry.

[5]  Abbas Afkhami,et al.  Construction of a modified carbon paste electrode for the highly selective simultaneous electrochemical determination of trace amounts of mercury(II) and cadmium(II) , 2012 .

[6]  C. Ahn,et al.  Potentiometric and voltammetric polymer lab chip sensors for determination of nitrate, pH and Cd(II) in water. , 2010, Talanta.

[7]  Claudio Nicolini,et al.  A Potentiometric Stripping Analyzer for Multianalyte Screening , 2007 .

[8]  R. Blake,et al.  Immunoassays for metal ions , 1998 .

[9]  Arben Merkoçi,et al.  Surface Characterizations of Mercury-Based Electrodes with the Resulting Micro and Nano Amalgam Wires and Spheres Formations May Reveal Both Gained Sensitivity and Faced Nonstability in Heavy Metal Detection , 2010 .

[10]  Xiaodong Chen,et al.  Flexible colorimetric detection of mercuric ion by simply mixing nanoparticles and oligopeptides. , 2011, Small.

[11]  Marc R. Knecht,et al.  Bio-inspired colorimetric detection of Hg2+ and Pb2+ heavy metal ions using Au nanoparticles , 2009, Analytical and bioanalytical chemistry.

[12]  T. Pradeep,et al.  Luminescent, freestanding composite films of Au15 for specific metal ion sensing. , 2012, ACS applied materials & interfaces.

[13]  Arben Merkoçi,et al.  Sensitive and stable monitoring of lead and cadmium in seawater using screen-printed electrode and electrochemical stripping analysis. , 2008, Analytica chimica acta.

[14]  Wei Wang,et al.  Paper disk on screen printed electrode for one-step sensing with an internal standard. , 2010, Analytical chemistry.

[15]  D. Blake,et al.  One-step competitive immunoassay for cadmium ions: development and validation for environmental water samples. , 2001, Analytical chemistry.

[16]  Guodong Liu,et al.  Lateral flow nucleic acid biosensor for Cu2+ detection in aqueous solution with high sensitivity and selectivity. , 2010, Chemical communications.

[17]  G. Ozolins,et al.  WHO guidelines for drinking-water quality. , 1984, WHO chronicle.

[18]  Yi Lu,et al.  Easy-to-use dipstick tests for detection of lead in paints using non-cross-linked gold nanoparticle-DNAzyme conjugates. , 2010, Chemical communications.

[19]  Leandro Lorenzelli,et al.  Development of an integrated electrochemical system for in vitro yeast viability testing. , 2013, Biosensors & bioelectronics.

[20]  Yasuhiro Sakurai,et al.  Immunochromatography for the rapid determination of cadmium concentrations in wheat grain and eggplant. , 2011, Journal of the science of food and agriculture.

[21]  Y. Sayato,et al.  WHO guidelines for drinking-water quality. , 1989 .

[22]  B. Connors,et al.  Integrated device for optical stimulation and spatiotemporal electrical recording of neural activity in light-sensitized brain tissue , 2009, Journal of neural engineering.

[23]  Hong-Wei Li,et al.  Dual-emission fluorescent silica nanoparticle-based probe for ultrasensitive detection of Cu2+. , 2011, Analytical chemistry.

[24]  Qiangqiang Fu,et al.  Colloidal gold nanoparticle probe-based immunochromatographic assay for the rapid detection of chromium ions in water and serum samples. , 2012, Analytica chimica acta.

[25]  Claudio Parolo,et al.  Paper-based nanobiosensors for diagnostics. , 2013, Chemical Society reviews.

[26]  D. Wylie,et al.  Metal Binding Properties of a Monoclonal Antibody Directed toward Metal-Chelate Complexes* , 1996, The Journal of Biological Chemistry.

[27]  Min-Gon Kim,et al.  A dual gold nanoparticle conjugate-based lateral flow assay (LFA) method for the analysis of troponin I. , 2010, Biosensors & bioelectronics.

[28]  D. Blake,et al.  Development and validation of a one-step immunoassay for determination of cadmium in human serum. , 2002, Analytical chemistry.

[29]  S. Mirgane,et al.  Heavy metal concentrations in groundwaters and soils of Thane Region of Maharashtra, India , 2011, Environmental monitoring and assessment.

[30]  Diane A. Blake,et al.  Detection of Heavy Metals by Immunoassay: Optimization and Validation of a Rapid, Portable Assay for Ionic Cadmium , 1998 .

[31]  Arben Merkoçi,et al.  Nanomaterials application in electrochemical detection of heavy metals , 2012 .

[32]  Xiliang Wang,et al.  Development and application of lateral flow test strip technology for detection of infectious agents and chemical contaminants: a review , 2010, Analytical and bioanalytical chemistry.

[33]  Mu-San Chen,et al.  Colored thin films for specific metal ion detection. , 2004, Environmental science & technology.

[34]  Arben Merkoçi,et al.  Recent trends in macro-, micro-, and nanomaterial-based tools and strategies for heavy-metal detection. , 2011, Chemical reviews.

[35]  Zhen Gu,et al.  Detection of mercury ion by infrared fluorescent protein and its hydrogel-based paper assay. , 2011, Analytical chemistry.

[36]  Arben Merkoçi,et al.  Enhanced electrochemical detection of heavy metals at heated graphite nanoparticle-based screen-printed electrodes , 2011 .

[37]  Sarit S. Agasti,et al.  Gold nanoparticles in chemical and biological sensing. , 2012, Chemical reviews.

[38]  Qing X. Li,et al.  Detection of copper ions using microcantilever immunosensors and enzyme-linked immunosorbent assay. , 2010, Analytica chimica acta.

[39]  Joseph Wang,et al.  A self-powered "sense-act-treat" system that is based on a biofuel cell and controlled by boolean logic. , 2012, Angewandte Chemie.

[40]  T. Ho,et al.  Determination of trace metals in seawater by an automated flow injection ion chromatograph pretreatment system with ICPMS. , 2010, Talanta.

[41]  Jaroslav Slamecka,et al.  Concentration of lead, cadmium, mercury and arsenic in leg skeletal muscles of three species of wild birds , 2010, Journal of environmental science and health. Part A, Toxic/hazardous substances & environmental engineering.

[42]  Arben Merkoçi,et al.  Rapid and highly sensitive detection of mercury ions using a fluorescence-based paper test strip with an N-alkylaminopyrazole ligand as a receptor , 2012 .