Effect of Different Signal Processing Techniques on a Calibration Free Pulse Oximeter

A pulse oximeter is a medical device that measures pulse rate and oxygen saturation levels of a person non-invasively. Monitoring of health parameters of a patient requires a device that gives accurate results in all conditions and is not affected by artifacts arising from environmental and physiological factors. One of the noise factors we focus in this paper is motion artifacts. These artifacts affect the quality of signal acquired by the sensor leading to imperfect results. In this paper, four digital filtering techniques, which include Exponential Moving Averaging, Savitzky-Golay, Independent Component Analysis and Discrete Kalman filter, are implemented to remove artifacts from a noisy photoplethysmographic signal acquired by shining lights in the range of Red and IR wavelengths on the fingertip of a person. Pulse rate is determined in the time domain by detecting peaks of the signal while blood oxygen levels are measured using Beer-Lambert Law via a calibration-free method on the artifact-free PPG signal. The results obtained are then compared with a commercial pulse oximeter available in the market and performance of different filtering techniques on a PPG signal is evaluated.

[1]  Erkki Oja,et al.  Independent component analysis: algorithms and applications , 2000, Neural Networks.

[2]  Aapo Hyvärinen,et al.  Fast and robust fixed-point algorithms for independent component analysis , 1999, IEEE Trans. Neural Networks.

[3]  S. Seyedtabaii,et al.  Kalman Filter Based Adaptive Reduction of Motion Artifact from Photoplethysmographic Signal , 2008 .

[4]  C. M. Lee,et al.  Reduction of motion artifacts from photoplethysmographic recordings using a wavelet denoising approach , 2003, IEEE EMBS Asian-Pacific Conference on Biomedical Engineering, 2003..

[5]  W. Zijlstra,et al.  Absorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin. , 1991, Clinical chemistry.

[6]  内海 孝信,et al.  私の留学体験記 The University of North Carolina at Chapel Hill , 2019 .

[7]  W. Zijlstra,et al.  Spectrophotometry of Hemoglobin: Absorption Spectra of Bovine Oxyhemoglobin, Deoxyhemoglobin, Carboxyhemoglobin, and Methemoglobin , 1997 .

[8]  Jaskirat Kaur,et al.  Low cost calibration free Pulse oximeter , 2015, 2015 Annual IEEE India Conference (INDICON).

[9]  Weidong Wang,et al.  Motion artifact removal from photoplethysmographic signals by combining temporally constrained independent component analysis and adaptive filter , 2014, Biomedical engineering online.

[10]  A. Savitzky,et al.  Smoothing and Differentiation of Data by Simplified Least Squares Procedures. , 1964 .

[11]  Toshiyo Tamura,et al.  Wearable Photoplethysmographic Sensors—Past and Present , 2014 .

[12]  Geevarghese Titus,et al.  Photoplethysmogram (PPG) signal analysis and wavelet de-noising , 2014, 2014 Annual International Conference on Emerging Research Areas: Magnetics, Machines and Drives (AICERA/iCMMD).

[13]  Boby George,et al.  A novel method for the measurement of oxygen saturation in arterial blood , 2011, 2011 IEEE International Instrumentation and Measurement Technology Conference.

[14]  M. Deo,et al.  “Doctor population ratio for India - The reality” , 2013, The Indian journal of medical research.

[15]  E. Hari Krishna,et al.  Use of Multi-Scale Principal Component Analysis for motion artifact reduction of PPG signals , 2011, 2011 IEEE Recent Advances in Intelligent Computational Systems.

[16]  S. Barker,et al.  Masimo Signal Extraction Pulse Oximetry , 2004, Journal of Clinical Monitoring and Computing.

[17]  Meltem Izzetoglu,et al.  Motion artifact cancellation in NIR spectroscopy using discrete Kalman filtering , 2010, Biomedical engineering online.

[18]  J. L. Roux An Introduction to the Kalman Filter , 2003 .

[19]  R. Schafer,et al.  What Is a Savitzky-Golay Filter? , 2022 .

[20]  T. Başar,et al.  A New Approach to Linear Filtering and Prediction Problems , 2001 .

[21]  Manan Bawa,et al.  Comparison of different signal processing methods for reducing artifacts from photoplethysmograph signal , 2011, 2011 IEEE INTERNATIONAL CONFERENCE ON ELECTRO/INFORMATION TECHNOLOGY.

[22]  Jun-Yeon Lee The Motion Artifact Reduction from the PPG based on EWMA , 2013 .

[23]  Berno J. E. Misgeld,et al.  An adaptive Kalman filter approach for cardiorespiratory signal extraction and fusion of non-contacting sensors , 2014, BMC Medical Informatics and Decision Making.