Development and application of a procedure to estimate overall building and ventilation parameters from monitored commercial building energy use

Development and Application of a Procedure to Estimate Overall Building and Ventilation Parameters from Monitored Commercial Building Energy Use. (May 1997) Song Deng, B.S., Harbin Architecture & Engineering Institute, Harbin, China Chair of Advisory Committee: Dr. David E. Claridge This thesis proposes and validates a simplified model appropriate for parameter identification and evaluates several different inverse parameter identification schemes suitable for use when heating and cooling data from a commercial building are available. The validation has been performed using such data generated from a detailed building simulation program for different building geometries and building mass levels in two different climatic locations. Such a synthetic evaluation will validate the model used as well as determine the best parameter identification scheme, i.e., one likely to yield the most accurate set of parameter estimates. A multistep identification scheme has been found to yield very accurate results, and a more careful evaluation has been performed in order to evaluate its accuracy and stability with synthetic data against the effects of solar energy, HVAC system operation, internal load schedule, building thermal mass and geometry, and climatic

[1]  David E. Claridge,et al.  A Four-Parameter Change-Point Model for Predicting Energy Consumption in Commercial Buildings , 1992 .

[2]  W. D. Turner Overview of the Texas LoanSTAR Monitoring Program , 1990 .

[3]  David E. Claridge,et al.  Using synthetic data to evaluate multiple regression and principal component analyses for statistical modeling of daily building energy consumption , 1994 .

[4]  Ari Rabl,et al.  Parameter estimation in buildings: Methods for dynamic analysis of measured energy use , 1988 .

[5]  Jeff Haberl,et al.  Graphical tools to help calibrate the DOE-2 simulation program , 1993 .

[6]  David E. Claridge,et al.  A Change-Point Principal Component Analysis (CP/PCA) Method for Predicting Energy Usage in Commercial Buildings: The PCA Model , 1993 .

[7]  M. R. Brambley,et al.  Advanced energy design and operation technologies , 1988 .

[8]  T. Agami Reddy Status of residential short-term performance monitoring methods , 1996 .

[9]  K. M. Greely,et al.  Measured savings and cost-effectiveness of conservation retrofits in commercial buildings , 1990 .

[10]  David E. Claridge,et al.  Use of Simplified System Models to Measure Retrofit Energy Savings , 1993 .

[11]  K. Subbarao,et al.  PSTAR: Primary and secondary terms analysis and renormalization: A unified approach to building energy simulations and short-term monitoring , 1988 .

[12]  Alan Meier,et al.  Testing the accuracy of a measurement-based building energy model with synthetic data , 1988 .