Numerical simulation of the seismic behavior of self-centering steel beam-column connections with bottom flange friction devices

A new type of steel moment resisting frame with bottom flange friction devices (BFFDs) has been developed to provide self-centering capacity and energy dissipation, and to reduce permanent deformations under earthquakes. This paper presents a numerical simulation of self-centering beam-column connections with BFFDs, in which the gap opening /closing at the beam-column interfaces is simulated by using pairs of zero-length elements with compression-only material properties, and the energy dissipation due to friction is simulated by using truss elements with specified hysteretic behavior. In particular, the effect of the friction bolt bearing against the slotted plate in the BFFDs was modeled, so that the increase in lateral force and the loss of friction force due to the bolt bearing could be taken into account. Parallel elastic-perfectly plastic gap (ElasticPPGap) materials in the Open System for Earthquake Engineering Simulation (OpenSees) were used with predefined gaps to specify the sequence that each bolt went into the bearing and the corresponding increase in bending stiffness. The MinMax material in OpenSees is used to specify the minimum and maximum values of strains of the ElasticPPGap materials. To consider the loss of friction force due to bolt bearing, a number of parallel hysteretic materials were used, and the failure of these materials in sequence simulated the gradual loss of friction force. Analysis results obtained by using the proposed numerical model are discussed and compared with the test results under cyclic loadings and the seismic loading, respectively.

[1]  Keh-Chyuan Tsai,et al.  Seismic self‐centering steel beam‐to‐column moment connections using bolted friction devices , 2008 .

[2]  Brian G. Morgen,et al.  Seismic Response Evaluation of Posttensioned Precast Concrete Frames with Friction Dampers , 2008 .

[3]  Richard Sause,et al.  Posttensioned Seismic-Resistant Connections for Steel Frames , 2001 .

[4]  Yu-Chi Wang,et al.  Seismic design and behavior of post-tensioned steel connections including effects of a composite slab , 2008 .

[5]  Jie Li,et al.  Steel self-centering moment frames with collector beam floor diaphragms , 2008 .

[6]  Chung-Che Chou,et al.  Post-tensioned self-centering moment connections with beam bottom flange energy dissipators , 2009 .

[7]  James M. Ricles,et al.  Self-centering MRFs with bottom flange friction devices under earthquake loading , 2009 .

[8]  Chung-Che Chou,et al.  Column restraint in post‐tensioned self‐centering moment frames , 2009 .

[9]  Chung-Che Chou,et al.  Tests and analyses of a full-scale post-tensioned RCS frame subassembly , 2010 .

[10]  Richard Sause,et al.  Seismic Performance of Post-tensioned Steel Moment Resisting Frames With Friction Devices , 2005 .

[11]  Richard Sause,et al.  Earthquake Simulations on a Self-Centering Steel Moment Resisting Frame with Web Friction Devices , 2009 .

[12]  Keh-Chyuan Tsai,et al.  Evaluating performance of post‐tensioned steel connections with strands and reduced flange plates , 2006 .

[13]  Dimitrios Vamvatsikos,et al.  Incremental dynamic analysis , 2002 .

[14]  Garrick D. Petty,et al.  Evaluation of a friction component for a post-tensioned steel connection , 1999 .

[15]  Andre Filiatrault,et al.  Posttensioned Energy Dissipating Connections for Moment-Resisting Steel Frames , 2002 .