Influence of CAD/CAM on the fit accuracy of implant-supported zirconia and cobalt-chromium fixed dental prostheses.

STATEMENT OF PROBLEM Relatively little information is available on the accuracy of the abutment-implant interface in computer-aided design and computer-aided manufacturing (CAD/CAM)-fabricated zirconia and cobalt-chromium frameworks. PURPOSE The purpose of this study was to compare the fit accuracy of CAD/CAM-fabricated zirconia and cobalt-chromium frameworks and conventionally fabricated cobalt-chromium frameworks. MATERIAL AND METHODS Four groups of 3-unit, implant-supported, screw-retained frameworks were fabricated to fit an in vitro model with 3 implants. Eight frameworks were fabricated with the CAD/CAM system: 4 in zirconia and 4 in cobalt-chromium. Another 8 were cast in cobalt-chromium with conventional casting, including 4 with premachined abutments and 4 with castable abutments. The vertical misfit at the implant-framework interface was measured with scanning electron microscopy when only 1 screw was tightened and when all screws were tightened. Data were analyzed with the Kruskal-Wallis and Mann-Whitney tests (α=.05). RESULTS The mean vertical misfit values when all screws were tightened was 5.9 ±3.6 μm for CAD/CAM-fabricated zirconia, 1.2 ±2.2 μm for CAD/CAM-fabricated cobalt-chromium frameworks, 11.8 ±9.8 μm for conventionally fabricated cobalt-chromium frameworks with premachined abutments, and 12.9 ±11.0 μm for the conventionally fabricated frameworks with castable abutments; the Mann-Whitney test found significant differences (P<.05) among all frameworks, except between the conventionally fabricated frameworks (P=.619). No significant differences were found among the groups for passive fit gap measurements (P>.05). CONCLUSIONS When all of the screws were tightened, the CAD/CAM frameworks exhibited better fit accuracy compared with the conventionally fabricated frameworks. High levels of passive fit were achieved for the evaluated techniques.

[1]  Matthias Karl,et al.  Effect of intraoral scanning on the passivity of fit of implant-supported fixed dental prostheses. , 2012, Quintessence international.

[2]  H. Zaghloul,et al.  Marginal fit of implant-supported all-ceramic zirconia frameworks. , 2013, The Journal of oral implantology.

[3]  Carl J Drago,et al.  Volumetric misfit in CAD/CAM and cast implant frameworks: a university laboratory study. , 2011, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[4]  Markus B Blatz,et al.  Precision of fit of implant-supported screw-retained 10-unit computer-aided-designed and computer-aided-manufactured frameworks made from zirconium dioxide and titanium: an in vitro study. , 2014, Clinical oral implants research.

[5]  Carl J Drago Two new clinical/laboratory protocols for CAD/CAM implant restorations. , 2006, Journal of the American Dental Association.

[6]  Torsten Jemt,et al.  The precision of fit of milled titanium implant frameworks (I-Bridge) in the edentulous jaw. , 2008, Clinical implant dentistry and related research.

[7]  P. Branemark Osseointegration and its experimental background. , 1983, The Journal of prosthetic dentistry.

[8]  Karl Lyons,et al.  Fit of screw-retained fixed implant frameworks fabricated by different methods: a systematic review. , 2011, The International journal of prosthodontics.

[9]  P. Neto,et al.  Accuracy of four transfer impression techniques for dental implants: a scanning electron microscopic analysis. , 2010, The International journal of oral & maxillofacial implants.

[10]  F. Beuer,et al.  Digital dentistry: an overview of recent developments for CAD/CAM generated restorations , 2008, BDJ.

[11]  S. Bernardes,et al.  Correlation between vertical misfits and stresses transmitted to implants from metal frameworks. , 2011, Journal of biomechanics.

[12]  F. D. Neves,et al.  Comparison of implant-abutment interface misfits after casting and soldering procedures. , 2013, The Journal of oral implantology.

[13]  Per Vult von Steyern,et al.  The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study. , 2011, Dental materials : official publication of the Academy of Dental Materials.

[14]  Torsten Jemt,et al.  Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible. , 2003, The International journal of prosthodontics.

[15]  K. Lyons,et al.  Effect of vertical misfit on strain within screw-retained implant titanium and zirconia frameworks. , 2012, Journal of prosthodontic research.

[16]  Daniel Edelhoff,et al.  Digital evaluation of the reproducibility of implant scanbody fit—an in vitro study , 2011, Clinical Oral Investigations.

[17]  Carl Drago,et al.  Volumetric determination of the amount of misfit in CAD/CAM and cast implant frameworks: a multicenter laboratory study. , 2010, The International journal of oral & maxillofacial implants.

[18]  Toshiyuki Takahashi,et al.  Fit of implant frameworks: an in vitro comparison between two fabrication techniques. , 2003, The Journal of prosthetic dentistry.

[19]  G. Bonfante,et al.  Use of base metal casting alloys for implant framework: marginal accuracy analysis. , 2004, Journal of applied oral science : revista FOB.

[20]  F. Watanabe,et al.  Analysis of stress distribution in a screw-retained implant prosthesis. , 2000, The International journal of oral & maxillofacial implants.

[21]  German O Gallucci,et al.  Computer-aided design and computer-assisted manufacturing in prosthetic implant dentistry. , 2009, The International journal of oral & maxillofacial implants.

[22]  M. Swain,et al.  A novel in vitro approach to assess the fit of implant frameworks. , 2011, Clinical oral implants research.

[23]  J Abduo,et al.  Fit of zirconia fixed partial denture: a systematic review. , 2010, Journal of oral rehabilitation.

[24]  F Houston,et al.  The fit of cast and premachined implant abutments. , 1998, The Journal of prosthetic dentistry.

[25]  T. Mattsson,et al.  Clinical performance of a method for the fabrication of implant-supported precisely fitting titanium frameworks: a retrospective 5- to 8-year clinical follow-up study. , 2004, Clinical implant dentistry and related research.

[26]  J. Brunski,et al.  Effects of fabrication, finishing, and polishing procedures on preload in prostheses using conventional "gold' and plastic cylinders. , 1996, The International journal of oral & maxillofacial implants.

[27]  Karl Lyons,et al.  Assessing the fit of implant fixed prostheses: a critical review. , 2010, The International journal of oral & maxillofacial implants.

[28]  Torsten Jemt,et al.  In vitro measurements of precision of fit of implant-supported frameworks. A comparison between "virtual" and "physical" assessments of fit using two different techniques of measurements. , 2012, Clinical implant dentistry and related research.

[29]  T. Jemt,et al.  Precision of fit to implants: a comparison of Cresco™ and Procera® implant bridge frameworks. , 2010, Clinical implant dentistry and related research.

[30]  M. de Mattos,et al.  Implant/abutment vertical misfit of one-piece cast frameworks made with different materials. , 2010, Brazilian dental journal.

[31]  M. Wichmann,et al.  Passivity of fit of CAD/CAM and copy-milled frameworks, veneered frameworks, and anatomically contoured, zirconia ceramic, implant-supported fixed prostheses. , 2012, The Journal of prosthetic dentistry.

[32]  M. Molmeneu,et al.  Analysis of the misfit of dental implant-supported prostheses made with three manufacturing processes. , 2014, The Journal of prosthetic dentistry.

[33]  C. Drago,et al.  Concepts for designing and fabricating metal implant frameworks for hybrid implant prostheses. , 2012, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[34]  M. Swain,et al.  Influence of vertical misfit of titanium and zirconia frameworks on peri-implant strain. , 2012, The International journal of oral & maxillofacial implants.

[35]  P. Manicone,et al.  An overview of zirconia ceramics: basic properties and clinical applications. , 2007, Journal of dentistry.

[36]  George A Zarb,et al.  A comparison of the accuracy of fit of 2 methods for fabricating implant-prosthodontic frameworks. , 2007, The International journal of prosthodontics.

[37]  Takashi Miyazaki,et al.  Effect of sintering on the marginal and internal fit of CAD/CAM-fabricated zirconia frameworks. , 2007, Dental materials journal.

[38]  M. Swain,et al.  A comparison of fit of CNC-milled titanium and zirconia frameworks to implants. , 2012, Clinical implant dentistry and related research.

[39]  T. Taylor,et al.  Strain Situation after Fixation of Three-Unit Ceramic Veneered Implant Superstructures , 2005, Implant dentistry.

[40]  R. Jung,et al.  Consensus statements and recommended clinical procedures regarding computer-assisted implant dentistry. , 2009, The International journal of oral & maxillofacial implants.

[41]  T. Jemt Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. , 1992, The International journal of oral & maxillofacial implants.

[42]  W. Att,et al.  Zirconia in fixed implant prosthodontics. , 2012, Clinical implant dentistry and related research.