Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection.

PURPOSE The aim of this study was to investigate the deviations of the implant positions of both impressions and casts using different impression materials and techniques. Furthermore, the existence of a correlation between the deviations of the impression and those of the cast was investigated. MATERIALS AND METHODS A reference model was fabricated with 5 Frialit-2 implants parallel to each other. In a standardized experimental setting, 5 stone casts were produced with 5 different techniques using polyether (A) or polyvinyl siloxane (B through E). In 3 groups, a direct technique was used with a medium-viscosity material or a putty-tray material in combination with a light-viscosity syringe material (A to C). In 2 groups, an indirect technique (either 1-step [group D] or 2-step [group E] was used with a putty-tray material in combination with a light-viscosity syringe material. The center-to-center distances were measured for impressions and casts in the horizontal plane using a computer-aided microscope, and the relative and absolute deviations compared to the reference model were calculated. Analysis of variance followed by the post-hoc Scheffé test (parametric data) or the Kruskal-Wallis test followed by pair-wise Mann-Whitney tests (nonparametric data) were used for statistical analyses. Deviations of impressions were compared with their respective casts using paired t tests and the Pearson correlation coefficient. RESULTS No significant differences for the relative deviations were found for impressions (-5 to -8 microm) or casts (+7 to +16 microm). Group E produced significantly higher absolute deviations for impressions (38 microm) and casts (39 microm) compared to the other groups (11 to 18 microm and 17 to 23 microm, respectively). A significant correlation between deviation of the impression and its respective cast was found for every group (r = 0.40 to 0.80) except group D. CONCLUSIONS The distortions in the horizontal plane of the casts obtained from the impression techniques of groups A to D would probably not affect the clinical fit of implant-retained superstructures. Because of the high variation of deviations (-113 to +124 microm), the 2-step technique cannot be recommended. The method to measure both impression and cast provided a better understanding of how inaccuracies are caused.

[1]  N D Millington,et al.  Inaccurate fit of implant superstructures. Part 1: Stresses generated on the superstructure relative to the size of fit discrepancy. , 1995, The International journal of prosthodontics.

[2]  P L Millstein,et al.  A comparative analysis of the accuracy of implant transfer techniques. , 1993, The Journal of prosthetic dentistry.

[3]  K. Akca,et al.  Accuracy of 2 impression techniques for ITI implants. , 2004, The International journal of oral & maxillofacial implants.

[4]  T Jemt,et al.  Photogrammetric measurements of implant positions. Description of a technique to determine the fit between implants and superstructures. , 1994, Clinical oral implants research.

[5]  Luis C F Frasca,et al.  Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments. , 2004, The International journal of oral & maxillofacial implants.

[6]  P. Vigolo,et al.  An evaluation of impression techniques for multiple internal connection implant prostheses. , 2004, The Journal of prosthetic dentistry.

[7]  P J Becker,et al.  Evaluation of impression accuracy for osseointegrated implant supported superstructures. , 2000, The Journal of prosthetic dentistry.

[8]  G Burawi,et al.  A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system. , 1997, The Journal of prosthetic dentistry.

[9]  B R Lang,et al.  Measuring fit at the implant prosthodontic interface. , 1996, The Journal of prosthetic dentistry.

[10]  A. Filippi,et al.  Long-term evaluation of submerged and nonsubmerged ITI solid-screw titanium implants: a 10-year life table analysis of 468 implants. , 2003, The International journal of oral & maxillofacial implants.

[11]  J. Hoffmann,et al.  Long-term results after placement of dental implants: longitudinal study of 1,964 implants over 16 years. , 1999, The International journal of oral & maxillofacial implants.

[12]  J I Nicholls,et al.  An evaluation of impression techniques for osseointegrated implants. , 1990, The Journal of prosthetic dentistry.

[13]  Torsten Jemt,et al.  Photogrammetry and conventional impressions for recording implant positions: a comparative laboratory study. , 2005, Clinical implant dentistry and related research.

[14]  E. Lenchewski,et al.  Clinical performance and 5-year retrospective evaluation of Frialit-2 implants. , 2004, The International journal of oral & maxillofacial implants.

[15]  J. Rubenstein,et al.  Comparison of interface relationships between implant components for laser-welded titanium frameworks and standard cast frameworks. , 1999, The International journal of oral & maxillofacial implants.

[16]  H. G. Filho,et al.  Evaluation of Transfer Impressions for Osseointegrated Implants at Various Angulations , 2004, Implant dentistry.

[17]  R Polansky,et al.  Comparison of the transfer precision of three different impression materials in combination with transfer caps for the Frialit-2 system. , 2000, Journal of oral rehabilitation.

[18]  D Assif,et al.  Accuracy of implant impression techniques. , 1996, The International journal of oral & maxillofacial implants.

[19]  T. Miyata,et al.  The influence of controlled occlusal overload on peri-implant tissue. Part 3: A histologic study in monkeys. , 2000, The International journal of oral & maxillofacial implants.

[20]  D Assif,et al.  Accuracy of implant impression splinted techniques: effect of splinting material. , 1999, The International journal of oral & maxillofacial implants.

[21]  Yong-Geun Choi,et al.  Comparison of dental implant systems: quality of clinical evidence and prediction of 5-year survival. , 2005, The International journal of oral & maxillofacial implants.

[22]  A Schmitt,et al.  The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part I: Surgical results. , 1990, The Journal of prosthetic dentistry.

[23]  P. Branemark,et al.  Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. , 1990, The International journal of oral & maxillofacial implants.

[24]  A Schmitt,et al.  The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto Study. Part II: The prosthetic results. , 1990, The Journal of prosthetic dentistry.

[25]  P I Brånemark,et al.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.

[26]  P. Vigolo,et al.  Evaluation of the accuracy of three techniques used for multiple implant abutment impressions. , 2003, The Journal of prosthetic dentistry.

[27]  Alvin G. Wee Comparison of impression materials for direct multi-implant impressions. , 2000, The Journal of prosthetic dentistry.

[28]  P Yaman,et al.  The accuracy of implant master casts constructed from transfer impressions. , 1990, The International journal of oral & maxillofacial implants.

[29]  S A Aquilino,et al.  Strategies to achieve fit in implant prosthodontics: a review of the literature. , 1999, The International journal of prosthodontics.

[30]  A B Carr,et al.  Comparison of impression techniques for a five-implant mandibular model. , 1992, The International journal of oral & maxillofacial implants.

[31]  S A Aquilino,et al.  Evaluation of three impression techniques for osseointegrated oral implants. , 1993, The Journal of prosthetic dentistry.

[32]  N S Javid,et al.  Prefabricated acrylic resin bars for splinting implant transfer copings. , 2000, The Journal of prosthetic dentistry.

[33]  T Jemt,et al.  Photogrammetry--an alternative to conventional impressions in implant dentistry? A clinical pilot study. , 1999, The International journal of prosthodontics.

[34]  A. Caputo,et al.  Passivity of fit and marginal opening in screw- or cement-retained implant fixed partial denture designs. , 2000, The International journal of oral & maxillofacial implants.

[35]  K. Lange,et al.  Retrospective evaluation of the success of oral rehabilitation using the Frialit-2 implant system. Part 1: Influence of topographic and surgical parameters. , 2004, The International journal of prosthodontics.

[36]  L. Giannetti,et al.  Comparative analysis of direct and indirect implant impression techniques an in vitro study. An in vitro study. , 2005, Minerva stomatologica.

[37]  G C Michaels,et al.  Effect of prosthetic superstructure accuracy on the osteointegrated implant bone interface. , 1997, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[38]  J I Nicholls,et al.  Tolerance measurements of various implant components. , 1997, The International journal of oral & maxillofacial implants.

[39]  J I Nicholls,et al.  Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials. , 1993, The International journal of prosthodontics.

[40]  A B Carr,et al.  The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit. , 1996, The Journal of prosthetic dentistry.

[41]  T Jemt,et al.  Prosthesis misfit and marginal bone loss in edentulous implant patients. , 1996, The International journal of oral & maxillofacial implants.