Evaluation of a Standardized Micro-Vacuum Sampling Method for Collection of Surface Dust

A standardized procedure for collecting dust samples from surfaces using a micro-vacuum sampling technique was evaluated. Experiments were carried out to investigate the collection efficiency of the vacuum sampling method described in ASTM Standard D7144, “Standard Practice for Collection of Surface Dust by Micro-Vacuum Sampling for Subsequent Metals Determination.” Weighed masses (≈ 5, ≈ 10 and ≈ 25 mg) of three NIST Standard Reference Materials (SRMs) were spiked onto surfaces of various substrates. The SRMs used were: (1) Powdered Lead-Based Paint; (2) Urban Particulate Matter; and (3) Trace Elements in Indoor Dust. Twelve different substrate materials were chosen to be representative of surfaces commonly encountered in occupational and/or indoor settings: (1) wood, (2) tile, (3) linoleum, (4) vinyl, (5) industrial carpet, (6) plush carpet, (7,8) concrete block (painted and unpainted), (9) car seat material, (10) denim, (11) steel, and (12) glass. Samples of SRMs originally spiked onto these surfaces were collected using the standardized micro-vacuum sampling procedure. Gravimetric analysis of material collected within preweighed Accucapinserts (housed within the samplers) was used to measure SRM recoveries. Recoveries ranged from 21.6% (± 10.4%, 95% confidence limit [CL]) for SRM 1579 from industrial carpet to 59.2% (± 11.0%, 95% CL) for SRM 1579 from glass. For most SRM/substrate combinations, recoveries ranged from ≈ 25% to ≈ 50%; variabilities differed appreciably. In general, SRM recoveries were higher from smooth and hard surfaces and lower from rough and porous surfaces. Material captured within collection nozzles attached to the sampler inlets was also weighed. A significant fraction of SRM originally spiked onto substrate surfaces was captured within collection nozzles. Percentages of SRMs captured within collection nozzles ranged from ≈ 13% (± 4 – ± 5%, 95% CLs) for SRMs 1579 and 2583 from industrial carpet to ≈ 45% (± 7 – ± 26%, 95% CLs) for SRM 1648 from glass, tile and steel. For some substrates, loose material from the substrate itself (i.e., substrate particles and fibers) was sometimes collected along with the SRM, both within Accucaps as well as collection nozzles. Co-collection of substrate material can bias results and contribute to sampling variability. The results of this work have provided performance data on the standardized micro-vacuum sampling procedure.

[1]  J. Stancliffe,et al.  Comparison of methods for monitoring solid particulate surface contamination in the workplace. , 1998, The Annals of occupational hygiene.

[2]  R L Bornschein,et al.  Evolution of efficient methods to sample lead sources, such as house dust and hand dust, in the homes of children. , 1985, Environmental research.

[3]  Kevin Ashley,et al.  Vacuum sampling techniques for industrial hygienists, with emphasis on beryllium dust sampling. , 2006, Journal of environmental monitoring : JEM.

[4]  D. Bartley,et al.  Effect of Sampler and Manikin Conductivity on the Sampling Efficiency of Manikin-Mounted Personal Samplers , 2003 .

[5]  D. A. Luke,et al.  Evaluation of four sampling methods for determining exposure of children to lead-contaminated household dust. , 1999, Environmental research.

[6]  H. S. Far,et al.  An evaluation of the significance of mouth and hand contamination for lead absorption in lead-acid battery workers , 1993, International archives of occupational and environmental health.

[7]  B. McArthur,et al.  Dermal Measurement and Wipe Sampling Methods: A Review , 1992 .

[8]  Jenny R. Roberts,et al.  Skin as a route of exposure and sensitization in chronic beryllium disease. , 2003, Environmental health perspectives.

[9]  M. Byrne Suction methods for assessing contamination on surfaces. , 2000, The Annals of occupational hygiene.

[10]  G M Piacitelli,et al.  Elevated blood lead levels in children of construction workers. , 1997, American journal of public health.

[11]  P. A. Baron,et al.  Aspiration Efficiency and Inlet Wall Deposition in the Fiber Sampling Cassette , 1996 .

[12]  B. King,et al.  Evidence of large particle allergen inhalation from contact with surfaces. , 1999, Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology.

[13]  L. Skare,et al.  Measuring dust on skin with a small vacuuming sampler--a comparison with other sampling techniques. , 2006, Annals of Occupational Hygiene.

[14]  S J Reynolds,et al.  Laboratory comparison of vacuum, OSHA, and HUD sampling methods for lead in household dust. , 1997, American Industrial Hygiene Association journal.

[15]  D E Jacobs,et al.  A side-by-side comparison of dust collection methods for sampling lead-contaminated house dust. , 1995, Environmental research.