Energy, exergy, economic and environmental (4E) analyses based comparative performance study and optimization of vapor compression-absorption integrated refrigeration system

Present work compares the performance of commercially available 170 kW vapor compression chiller with equivalent three configurations (parallel, series and combined series-parallel) of VCAIRS (vapor compression-absorption integrated refrigeration system) based on combined energy, exergy, economic and environmental (4E) analyses. Parallel, series and combined series-parallel configurations reduces the energy (electricity) consumption in the compressor by 50%, 76.8% and 88.3% respectively and consequently, reduce the significant amount of CO2 emission. Comparative exegetic analysis based on modified Gouy–Stodola law was performed which predicted higher irreversibility rate as compared to conventional approach. The thermoeconomic study shows that annual cost of the plant operation is 13.8%, 20.9% and 24.7% less for parallel, series and combined series-parallel configurations respectively as compared to equivalent VCRS (vapor compression refrigeration system) and after optimization, the same is further reduced by 8.1%, 8.5% and 4.7% respectively from the base value.

[1]  Georgios A. Florides,et al.  Design and construction of a LiBr–water absorption machine , 2003 .

[2]  Kiyoshi Saito,et al.  Static characteristics and efficient control of compression- and absorption-type hybrid air conditioning system , 2011 .

[3]  Sepehr Sanaye,et al.  Thermal and economical optimization of air conditioning units with vapor compression refrigeration system , 2004 .

[4]  Mehran Ameri,et al.  Energy and exergy comparison of a cascade air conditioning system using different cooling strategies , 2014 .

[5]  Surendra Singh Kachhwaha,et al.  Thermodynamic performance analysis of a vapor compression–absorption cascaded refrigeration system , 2013 .

[6]  S. S. Murthy,et al.  Solar-assisted vapor compression/absorption cascaded air-conditioning systems , 1993 .

[7]  Mahmood Yaghoubi,et al.  Thermoeconomic Methodology for Analysis and Optimization of a Hybrid Solar Thermal Power Plant , 2013 .

[8]  Alberto Coronas,et al.  Integration of trigeneration in an indirect cascade refrigeration system in supermarkets , 2011 .

[9]  Ibrahim Dincer,et al.  Exergy Analysis of a Gasification-Based Combined Cycle with Solid Oxide Fuel Cells for Cogeneration , 2011 .

[10]  G. Alefeld,et al.  Experimental investigation of heat transfer in a horizontal tube falling film absorber with aqueous solutions of LiBr with and without surfactants , 1996 .

[11]  Juan M. Belman-Flores,et al.  NLP model of a LiBr–H2O absorption refrigeration system for the minimization of the annual operating cost , 2012 .

[12]  Markku J. Lampinen,et al.  Exergy analysis for stationary flow systems with several heat exchange temperatures , 1995 .

[13]  Fabio Rinaldi,et al.  Exergetic, economic and environmental (3E) analyses, and multi-objective optimization of a CO2/NH3 cascade refrigeration system , 2014 .

[14]  Ilhan Ozturk,et al.  Analysis of compression–absorption cascade refrigeration cycles , 2012 .

[15]  M. Ameri,et al.  Analysis of integrated compression–absorption refrigeration systems powered by a microturbine , 2012 .

[16]  Surendra Singh Kachhwaha,et al.  NLP model based thermoeconomic optimization of vapor compression–absorption cascaded refrigeration system , 2015 .

[17]  Zhiqiang Zhai,et al.  Particle swarm optimization for redundant building cooling heating and power system , 2010 .

[18]  Chander P Arora,et al.  Refrigeration and Air Conditioning , 1983 .

[19]  Surendra Singh Kachhwaha,et al.  Performance analysis of a vapour compression-absorption cascaded refrigeration system with undersized evaporator and condenser , 2017 .

[20]  Yingying Tan,et al.  Study on Solar-Assisted Cascade Refrigeration System , 2012 .

[21]  Selahattin Göktun,et al.  The optimum performance of a solar-assisted combined absorption–vapor compression system for air conditioning and space heating , 2001 .

[22]  Suresh V. Garimella,et al.  Multi-objective optimization of sustainable single-effect water/Lithium Bromide absorption cycle , 2012 .

[23]  Surendra Singh Kachhwaha,et al.  Exergy analysis of a vapour compression–absorption cascaded refrigeration system using modified Gouy–Stodola equation , 2014 .

[24]  Ali Behbahaninia,et al.  Thermoeconomic optimization and exergy analysis of CO 2/NH 3 cascade refrigeration systems , 2011 .

[25]  Soteris A. Kalogirou,et al.  Thermoeconomic optimization of a LiBr absorption refrigeration system , 2007 .

[26]  Pekka Ruohonen,et al.  Determination of the Real Loss of Power for a Condensing and a Backpressure Turbine by Means of Second Law Analysis , 2009, Entropy.

[27]  Olcay Kincay,et al.  Thermoeconomic optimization of LiBr/H2O-R134a compression-absorption cascade refrigeration cycle , 2015 .

[28]  V. Gnielinski New equations for heat and mass transfer in turbulent pipe and channel flow , 1976 .

[29]  Hoseyn Sayyaadi,et al.  Multi-objective optimization of a cooling tower assisted vapor compression refrigeration system , 2011 .

[30]  Surendra Singh Kachhwaha,et al.  Thermodynamic modelling and parametric study of a low temperature vapour compression-absorption system based on modified Gouy-Stodola equation , 2015 .

[31]  W. Rohsenow,et al.  Handbook of Heat Transfer , 1998 .

[32]  Berhane H. Gebreslassie,et al.  Design of environmentally conscious absorption cooling systems via multi-objective optimization and life cycle assessment , 2009 .

[33]  Markku Lampinen,et al.  Theory of Effective Heat-Absorbing and Heat-Emitting Temperatures in Entropy and Exergy Analysis with Applications to Flow Systems and Combustion Processes , 2006 .

[34]  Guangming Chen,et al.  Experimental study on HFC-161 mixture as an alternative refrigerant to R502 , 2005 .

[35]  E. Nehdi,et al.  Cooling performance and energy saving of a compression–absorption refrigeration system assisted by geothermal energy , 2006 .

[36]  D. Colorado,et al.  Exergy analysis of a compression–absorption cascade system for refrigeration , 2013 .

[37]  J. Paris,et al.  A model for analysis and design of H2O–LiBr absorption heat pumps , 2011 .

[38]  Surendra Singh Kachhwaha,et al.  ENERGY ANALYSIS OF A VAPOR COMPRESSION SYSTEM CASCADED WITH AMMONIA–WATER ABSORPTION SYSTEM , 2014 .

[39]  Z. Sun Experimental investigation of integrated refrigeration system (IRS) with gas engine, compression chiller and absorption chiller , 2008 .

[40]  José Fernández-Seara,et al.  Compression–absorption cascade refrigeration system , 2006 .

[41]  Srinivas Garimella,et al.  Waste heat driven absorption/vapor-compression cascade refrigeration system for megawatt scale, high-flux, low-temperature cooling , 2011 .

[42]  Z. G. Sun,et al.  Cooling performance and energy saving of a compression–absorption refrigeration system driven by a gas engine , 2006 .